Type| Driver type| Power| UGR| CCT| IP| Voltage| Frequency| Dimension (mm)|
---|---|---|---|---|---|---|---|---|---
RC199V LED36/840 PSU W60L60 OC| RC199V LED35/940 PSU W60L60 OC| PSU| 23| 19| 4000K| IP20/IP40| 220 240V~| 50/60Hz| 59559535| 1.6
RC199V LED39/840 PSU W60L60| RC199V LED37/940 PSU W60L60| 23| 22| 59559534| 1.5
RC199V LED35/840 PSD W60L60 OC| RC199V LED34/940 PSD W60L60 OC| PSD| 23| 19| 59559535| 1.6
RC199V LED37/840 PSD W60L60| RC199V LED35/940 PSD W60L60| 23| 22| 59559534| 1.5
RC199X LED35/840 WIA W60L60 OC| RC199X LED33/940 WIA W60L60 OC| WIA| 22| 19| 59559535| 1.6
RC199X LED38/840 WIA W60L60| RC199X LED35/940 WIA W60L60| 22| 22| 59559534| 1.5
RC199V LED36/840 PSU W30L120 OC| RC199V LED35/940 PSU W30L120 OC| PSU| 23| 19| 119529535| 1.6
RC199V LED39/840 PSU W30L120| RC199V LED37/940 PSU W30L120| 23| 22| 119529534| 1.4
RC199V LED35/840 PSD W30L120 OC| RC199V LED34/940 PSD W30L120 OC| PSD| 23| 19| 119529535| 1.6
RC199V LED37/840 PSD W30L120| RC199V LED35/940 PSD W30L120| 23| 22| 119529534| 1.4
RC199X LED35/840 WIA W30L120 OC| RC199X LED33/940 WIA W30L120 OC| WIA| 22| 19| 119529535| 1.6
RC199X LED38/840 WIA W30L120| RC199X LED35/940 WIA W30L120| 22| 22| 119529534| 1.4
RC199V LED54/840 PSU W60L120 OC| RC199V LED51/940 PSU W60L120 OC| PSU| 33| 19| 119559535| 3.3
RC199V LED57/840 PSU W60L120| RC199V LED53/940 PSU W60L120| 33| 22| 119559534| 3.0
RC199V LED54/840 PSD W60L120 OC| RC199V LED50/940 PSD W60L120 OC| PSD| 33.5| 19| 119559535| 3.3
RC199V LED56/840 PSD W60L120| RC199V LED53/940 PSD W60L120| 33.5| 22| 119559534| 3.0
RC199X LED54/840 WIA W60L120 OC| RC199X LED50/940 WIA W60L120 OC| WIA| 33| 19| 119559535| 3.3
RC199X LED57/840 WIA W60L120| RC199X LED53/940 WIA W60L120| 33| 22| 119559534| 3.0

Caution: The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

Dimensions

W60L60
Dimension

W30L120
W60L120
Dimension

Recessed

  1. Tear off the tape protective paper
    W60L60
    W30L120
    **W60L120

**

  1. Stick the driver onto the backplane


  2. Adjust the luminaire position to fit ceiling
    Recessed
    Recessed

Wiring Method

Wiring Method

Please use IP20 or above terminal box(dimension shall be greater than 10x20x25mm), it is not provided by Signify.

  • For type Y attachments:
    If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

  • Basic insulation between LV supply and control conducts.

Product Type| Start(Inrush) Current(A) /I peak(A)| Start Current Duration( s)/T(@50% of I peak) (  s)| * Touch current or protective conductor current (mA)| Run Current (A)(@220V)| MCB Type B 16A (or Type C 16A) Max no. fitting (pcs)| Inrush current

---|---|---|---|---|---|---
RC199V W60L60/W30L120 PSU| 36| 210| <0.7| 0.13| 29
RC199V W60L120 PSU| 39| 210| 0.17| 26
RC199V W60L60/W30L120 PSD| 36| 210| 0.13| 29
RC199V W60L120 PSD| 39| 210| 0.17| 26
RC199X W60L60/W30L120 WIA| 36| 210| 0.13| 29
RC199X W60L120 WIA| 39| 210| 0.17| 26

The leakage current (touch current or protective conductor current) of electrical circuit may be greatly dependent upon electrical supply cables used such as its rating and length, proper connection of electrical supply cables to luminaires and wiring connection topology of luminaires to the supply electrical circuit amongst other site conditions. In some cases referred to as Earth Leakage Current

Safety Chain

Safety Chain

The product shall install safety chain before use. (Safety chain is not included, needs to be ordered separately)
Safety chain order info 911401892080 RC132Z SC

  1. Indoor use only. The luminaire shall, under no circumstance, be covered with thermal insulation matting or similar material.
  2. Do not switch on before complete installation.
  3. The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  4. The luminaire shall ,under no circumstance, be covered with insulation matting or similar material.
  5. Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur, Chlorine, phthalates, etc, are present.
  6. The product is IPX0 & as such is not protected against water ingress & as such we strongly recommend that the environment in which the luminaire is to be installed is suitably checked If the above advice is not taken and the luminaires are subject to water ingress, Philips / Signify cannot guarantee safe failure & product warranty will become void

Disposal

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling

Other Model

Product Specification

Symbols

Type| Driver type| Power| UGR| CCT| IP| Voltage| Frequency| Dimension (mm)|
---|---|---|---|---|---|---|---|---|---
RC199V LED36/840 PSU W60L60 OC CAU| RC199V LED35/940 PSU W60L60 OC CAU| PSU| 23| 19| 4000K| IP20/IP40| 220-240V~| 50/60Hz| 59559535| 1.7
RC199V LED39/840 PSU W60L60 CAU| RC199V LED37/940 PSU W60L60 CAU| 23| 22| 59559534| 1.6
RC199V LED35/840 PSD W60L60 OC CAU| RC199V LED34/940 PSD W60L60 OC CAU| PSD| 23| 19| 59559535| 1.7
RC199V LED38/840 PSD W60L60 CAU| RC199V LED36/940 PSD W60L60 CAU| 23| 22| 59559534| 1.6
RC199X LED36/840 WIA W60L60 OC CAU| RC199X LED34/940 WIA W60L60 OC CAU| WIA| 22| 19| 59559535| 1.7
RC199X LED38/840 WIA W60L60 CAU| RC199X LED35/940 WIA W60L60 CAU| 22| 22| 59559534| 1.6
RC199V LED36/840 PSU W30L120 OC CAU| RC199V LED35/940 PSU W30L120 OC CAU| PSU| 23| 19| 119529535| 1.7
RC199V LED39/840 PSU W30L120 CAU| RC199V LED37/940 PSU W30L120 CAU| 23| 22| 119529534| 1.5
RC199V LED35/840 PSD W30L120 OC CAU| RC199V LED34/940 PSD W30L120 OC CAU| PSD| 23| 19| 119529535| 1.7
RC199V LED38/840 PSD W30L120 CAU| RC199V LED36/940 PSD W30L120 CAU| 23| 22| 119529534| 1.5
RC199X LED36/840 WIA W30L120 OC CAU| RC199X LED34/940 WIA W30L120 OC CAU| WIA| 22| 19| 119529535| 1.7
RC199X LED38/840 WIA W30L120 CAU| RC199X LED35/940 WIA W30L120 CAU| 22| 22| 119529534| 1.5
RC199V LED54/840 PSU W60L120 OC CAU| RC199V LED51/940 PSU W60L120 OC CAU| PSU| 33.5| 19| 119559535| 3.4
RC199V LED58/840 PSU W60L120 CAU| RC199V LED54/940 PSU W60L120 CAU| 33.5| 22| 119559534| 3.1
RC199V LED54/840 PSD W60L120 OC CAU| RC199V LED50/940 PSD W60L120 OC CAU| PSD| 33.5| 19| 119559535| 3.4
RC199V LED56/840 PSD W60L120 CAU| RC199V LED53/940 PSD W60L120 CAU| 33.5| 22| 119559534| 3.1
RC199X LED54/840 WIA W60L120 OC CAU| RC199X LED50/940 WIA W60L120 OC CAU| WIA| 33| 19| 119559535| 3.4
RC199X LED57/840 WIA W60L120 CAU| RC199X LED53/940 WIA W60L120 CAU| 33| 22| 119559534| 3.1

Caution: The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.

Dimensions

Recessed

  1. Tear off protective paper
    W60L60
    W30L120
    **W60L120

**

  1. Stick the driver onto the backplane


  2. Adjust the luminaire position to fit ceiling

WARNING-RISK OF OVERHEATING OR FIRE IF THE CLEARANCE DISTANCES ARE COMPROMISED RISK OF FIRE-REQUIRED CLEARANCE FROM STRUCTURAL MEMBERS AND BUILDING ELEMENTS HCB=20mm MIC=20mm SCB=50mm SCI=0mm

(i) HCB(Height clearance to building element)
(ii) MIC (Minimum insulation clearance)
(iii) SCB(Side clearance to building element)
(iv) SCI(Side clearance to insulation)

Wiring Method

Plug Cord Length ≈ 560mm
Plug into the socket properly

  • For type Y attachments: If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.
  • Basic insulation between LV supply and control conducts.

Safety Chain

Safety Chain

The product shall install safety chain before use. (Safety chain is not included, needs to be ordered separately)
Safety chain order info: 911401892080 RC132Z SC

Product Type| Start(Inrush) Current(A) /I peak(A)| Start Current Duration( s) /T(@50% of I peak) ( s)| * Touch current or protective conductor current (mA)| Run Current (A (@220V)| MCB Type B 16A (or Type C 16A) Max no. fitting (pcs)| Inrush current

---|---|---|---|---|---|---
RC199V W60L60/W30L120 PSU| 36| 210| <0.7| 0.13| 29
RC199V W60L120 PSU| 39| 210| 0.17| 26
RC199V W60L60/W30L120 PSD| 36| 210| 0.13| 29
RC199V W60L120 PSD| 39| 210| 0.17| 26
RC199X W60L60/W30L120 WIA| 36| 210| 0.13| 29
RC199X W60L120 WIA| 39| 210| 0.17| 26

  1. Indoor use only. The luminaire shall, under no circumstance, be covered with thermal insulation matting or similar material.
  2. Do not switch on before complete installation.
  3. The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  4. The luminaire shall ,under no circumstance, be covered with insulation matting or similar material.
  5. Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur, Chlorine, phthalates, etc, are present.
  6. The product is IPX0 & as such is not protected against water ingress & as such we strongly recommend that the environment in which the luminaire is to be installed is suitably checked If the above advice is not taken and the luminaires are subject to water ingress, Philips / Signify cannot guarantee safe failure & product warranty will become void
  7. For controllable luminaires basic insulation has been maintained between LV supply and control conductors.

Disposal

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

Customer Support

Signify Luminaires (Shanghai) Co., Ltd.
Address: 2F, Building 1, No. 2555, Hechuan Road, Minhang District, SH, PRC
Postalcode: 200233

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals