HOOVER 39300209 Mattress Cleaner User Manual
- June 17, 2024
- Hoover
Table of Contents
USER MANUAL 39300209 Mattress Cleaner
39300209 Mattress Cleaner
INSTRUCTIONS FOR SAFE USE
This appliance should only be used for mattress, blanket, pillow, cushion,
sofa and other textiles cleaning, as described in this user guide. Please
ensure that this guide is fully understood before operating the appliance.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision. If the power cord is
damaged stop using the appliance immediately. To avoid a safety hazard, an
authorised Hoover service engineer must replace the power cord.
Use only attachments, consumables or spares recommended or supplied by Hoover.
Do frequently clean the dust cup and pre-motor filter assembly.
Do not leave the appliance plugged in. Always switch off and remove the plug
from the socket after use, or before cleaning the appliance or any maintenance
task.
Do not pick up hard or sharp objects, matches, hot ashes, cigarette ends or
other similar items.
This product is with UV lamp, avoid watching the bottom of the machine in the
case of power on, to prevent UV radiation damage to human body.
Do not spray with or pick up flammable liquids, cleaning fluids, aerosols or
their vapours.
Please do not use UV lamp to concentrate on working in one place for
continuous use, this may damage the cleaning object.
Do not continue to use your appliance if it appears faulty.
Do not use the appliance to clean animals or people.
Do not use your appliance out of doors or on any wet surface or for wet pick
up.
WARNING: This appliance contains a UV emitter. Do not stare at the light
source.
Hoover service: To ensure the continued safe and efficient operation of this
appliance we recommend that any servicing or repairs are only carried out by
an authorised Hoover service engineer.
Static electricity: Some blankets can cause a small build up of static
electricity. Any static discharge is not hazardous to health.
GETTING TO KNOW YOUR MATTRESS CLEANER
A. Function Button
B. Power Button
C. Dust Cup Assembly
D. Indicator Lamps
D1 – Vacuum Indicator
D2 – Agitator Indicator
D3 – UV Lamp Indicator
E. Dust Cup Top Cover
F. Dust Cup Lower Cover
G. Pre-Motor Filter
H. Mesh
I. Dust Cup
J. Dust Cup Release Cover
K. Power Cord
L. UV Lamp
M. UV Lamp Cover Plate
N. Rotating Agitator
O. Agitator Cover Plate
USING YOUR MATTRESS CLEANER
Make sure all the components are correctly assembled, Extract the power cord
and plug into the power supply.
The appliance will make a 3 tone sound to indicate it is ready to start.
-
Vacuum + Rotating Agitator + UV Lamp mode
Press the on/off button [1], the appliance will automatically start up all 3 modes, Vacuum, Rotating Agitator and UV Lamp.
This will be indicated by 3 illuminated indicator lamps D1, D2 & D3.
At this setting, the appliance will use the UV radiation to kill mites, bacteria, and other harmful organisms.
The rotating agitator will disturb and loosen any dust allowing the appliance to vacuum the debris into the dust cup. -
Vacuum + Rotating Agitator mode
Press the on/off button [1], the appliance will automatically start up all 3 modes, Vacuum, Rotating Agitator and UV Lamp, to switch off the UV lamp, press the Function Button once [1].
This will be shown by 2 illuminated indicator lamps D1 & D2.
At this setting, the appliance will use the rotating agitator to disturb and loosen any dust allowing the appliance to vacuum the debris into the dust cup. -
Vacuum + UV Lamp mode
Press the on/off button [1], the appliance will automatically start up all 3 modes, Vacuum, Rotating Agitator and UV Lamp, to switch off the Rotating Agitator, press the Function Button twice [1].
This will be shown by 2 illuminated indicator lamps D1 & D3.
At this setting, the appliance will use the UV radiation to kill mites, bacteria, and other harmful organisms.
The Vacuum function will vacuum the debris into the dust cup.
WARNING: In order to avoid accidental injury , the UV lamp WILL ONLY WORK
when within a distance of 5cm from the object being cleaned or at a working
angle less than 30 degrees. If the cleaner is outside these parameters then
the UV LAMP INDICATOR D3 and the UV lamp will SWITCH OFF AUTOMATICALLY.
At any time during use, press the On/Off Button to switch the appliance off.
MATTRESS CLEANER MAINTENANCE
-
Dust Cup Cleaning
Turn off the appliance, unplug the power, press the dust cup release button and remove the dust cup assembly [2,3].
Rotate the dust cup and remove [4] Empty the contents of the dust cup and clean [5].
Unlatch the dust cup top cover [6], remove the Pre-motor filter and wash with hand warm water [7], allow to dry thoroughly before replacing in the appliance. Rinse and wipe clean any dust build up on the Mesh [7] After cleaning, refit the dust cup to main body [8,9].
Cleaning the Washable Filters
To maintain optimum cleaning performance regularly remove the filters and tap against the side of the bin to release dust. The filters should be washed under hand warm water when the filter has excessive dust level. Do not use hot water or detergents.
IMPORTANT: All bagless cleaners require regular filter cleaning. Failure to clean your filters may result in air blockage, overheating and product failure. This may invalidate your guarantee.
IMPORTANT: Always ensure the filters are fully dry before use. Do not use the product without the filter fitted. -
Agitator Cleaning
To remove the agitator cover plate, remove the screw, press the 4 release clips and remove the agitator cover plate [10].
Using scissors, carefully cut and remove any tangled threads or hair etc from the agitator body.
After cleaning replace the agitator cover [11] and secure the cover in place using the screw. -
UV Lamp Cleaning
To remove the UV Lamp cover plate, remove the 2 screws [12] and remove the UV cover plate.
Use a dry soft cloth or cotton swab to gently wipe clean the lamp [12].
After cleaning replace the UV Lamp cover plate and secure the cover in place using the 2 screws.
IMPORTANT:
- The penetrability of the UV lamp is weak, any paper, lead, glass or plastic may greatly reduce the intensity of UV irradiation. Any dust or oil on the UV lamp will directly affect the penetrability. The UV lamp should be cleaned regularly.
- Do not touch the UV lamp with your bare finger, the stain you leave on it will affect the penetration of sterilization light.
- Regularly check and maintain the filters.
- If the appliance will not be used for a long time, please store the appliance in a cool dry place, do not store your appliance in damp conditions or in direct sunlight.
TROUBLE SHOOTING
The following is a list of commonly encountered problems and solutions.
If any of these problems persist contact your local Hoover representative.
The Mattress Cleaner does not work| 1. Is there a working electricity supply
to the appliance?
2. Has the appliance been switched on?| 1. Check the power supply with
another electrical product.
2. Switch on the Power Button.
---|---|---
Reduced Suction| 1. Is the appliance blocked?
2. Is the Pre-Motor Filter Blocked?| 1. Clean the suction inlet.
2. Clean up the dust cup and Pre-motor filter.
UV lamp does not work| 1. The reflection of the object surface is very poor
or is too far away from the appliance.
2. Is the appliance being used at an angle over 30 degrees?
3. Is the infrared sensor on the bottom of the appliance dirty?
4. Is the UV lamp damaged?| 1. Normally the UV lamp will turn on
automatically within 5 cm of the cleaning surface.
2. Appliance must be used at less than a 30 degree angle for the UV Lamp to
operate.
3. Clean the sensors with a semi-dry cotton cloth.
4. Contact Hoover after-sales service to replace the UV lamp.
Mattress stops working suddenly| 1. Has the appliance overheated?| In order
to avoid the motor overheating, security mechanisms have been added. If this
happens, stop using the appliance, clean the Pre-Motor Filter and Dust Cup.
Wait two hours for the appliance to reset before re-using.
IMPORTANT INFORMATION
Hoover spares and Consumables
Always replace parts with genuine Hoover spares. These are available from your
local Hoover dealer or direct from Hoover. When ordering parts always quote
your model number.
The Environment:
The symbol on the product indicates that this product may not be treated as
household waste. Instead it shall be handed over to the appliance collection
point for recycling of electrical and electronic equipment. Disposal must be
carried out in accordance with the local environmental regulations for waste
disposal. For more detailed information about treatment, recovery and
recycling of this product, please contact your local city office, your
household waste disposal service or the shop where you purchased the product.
**** This product complies with the European Directives 2014/35//EC,
2014/30/EC and 2011/65/EC.
CANDY HOOVER GROUP S.r.l. Via Privata Eden Fumagalli, 20861 Brugherio (MB)
Italy
YOUR GUARANTEE
The guarantee conditions for this appliance are as defined by our
representative in the country in which it is sold.
Details regarding these conditions can be obtained from the dealer from whom
the appliance was purchased.
The bill of sale or receipt must be produced when making any claim under the
terms of this guarantee.
Subject to change without notice.
Printed in China/P.R.C.
48015928/03
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>