Seren BUN_SERCHPAN_89558 Dual Flush Valve User Manual
- June 17, 2024
- Seren
Table of Contents
Seren BUN_SERCHPAN_89558 Dual Flush Valve
INSTALLATION LAYOUT
TIPS
- Read all manipulation and installation guidelines, and please install 11 step by step according to the installation guidelines and prevent any damage from product breakage and improper use.
- All material are written according to the latest information when design. Our company reserve the right to change product characteristics, package and supply at any time without notice.
- Do not use corrosive detergent (such as hypochlorite) in water tank because such strong oxidant makes fittings damaged easily and lead to leakage. The above mentioned situations are beyond the range of our guarantee.
- Our company do not bear the related loses and damages caused by use other company’s parts and material such as glass glue.
- Suitable temperature range: 0-45″C
Functional Instruction
- The flush valve has 2 flushing ways· half-flush and full flush: when you push the full flush. the discharge volume is big and when you push the half flush, the discharge volume is small.
- Water level of half flush is adjustable. (Refer to photo 61
- Water level of full flush Is adjustable. (Refer to photo 3-21
Installation Steps
Preparation before Installation
Remove the old fittings and wash tanl before mstallatton. And wash clean
because many ImpuntIes probably existed In conduit.
Flush Valve Installation (According to the actual need)
-
Stainless steel hook for one-piece flush valve installation.
-
Contrarotate drainage body and make it remove from pedestal.
-
Circumrotate stainless steel hook to the end of bolt clockwise
-
Let pedestal aim at the water tank scupper, deflect properly. circumrotate, and, the stainless steel hook can reach the scupper downside, then, revise the pedesta the searing washer should put upside. Go through the pedestal by the middle finger of left hand to keep off stainless steel hook and make its both sides put around the outfall symmetrically.
-
Circumrotate bolt by screwdriver and be sure that seal between sealing washer and the surrounding for outfall.
-
Let flush valve body insert into pedestal and circumrotate it inside the buckle clockwise.
-
TWo-piece flush valve Installation
-
Contrarotate drainage body and make it removed from pedestal,
-
Let pedestal insert into outfall from inside of water tank, cover the drainage plastic washer, circumrotate drainage nut and cover the standard washer, and it can adjust the put angle properly according to the actual size of water tank.
-
Let flush valve body insert into pedestal and circumrotate it inside the buckle clockwise.
Notice : If the product is different from the photo shown, please refer to the actual product. -
Fill Valve Installation
-
Put fill valve & water inlet triangle washer nsert into water inlet hole of water tank, then, cover water inle plastic washer and hexagonal nut in turn from the bottom of fill valve. Fastening water -inlet hexagonal nut and make a proper adjust according to the size of water tank.
-
Adjust water levet Fetch out buckde and screw off water-inlet body anti-clockwise: pull upside or press downside to the proper situation, then, screwing on the water-inlet body closely and install the buckle. Little adjustment on water level: revolve adjusted rod to adjust the height of water -stop cup and buơy to reach the suitable water level wou need
-
Connect water-suppy pipe and bult in adapter or filter appording to your actual need.
Notice : -
Be sure that buoy is active freely before fil valve installation.
-
Wash the impurity in the conduit when you connecting water-supply pipe.
-
The height of water level can not beyond overflow mouth of flush valve when adjusting water level.
-
Water tank Installation
Put water tank on ceramic toilet and make standard washer located at the outfall of toilet. Just the photo shows, let jointed bolt insert into installation hole, then, screw the jointed nut closely. -
Examination
As photo show, connect water-inlet pipe to test and notice the following phenomenon: -
According to the height of half flush to adjust half flush water level: when half flush buoy is higher, the drainage volume is less; when it is lower, the drainage volume is more.
-
Adjust the height of water level by the adjusted digit and its corresponding adjusted patch. The placket is big and its water level is high; the placket is small and its water level is low (Note: When adjusting full flush water level, please fetch out flush valve, then, install flush valve again correctly after adjusted.)
-
Adjust all parts position to prevent them from interference.
-
Open & close for water-stop cup is normal and has no leakage. 5. It is normal for full flush and half flush.
-
Push button Installation
-
Screw off push button nut.
-
Let push button insert into water tank lid middle hole, screwing on push button nut from the bottom of water tank lid, then, screwing the acjusted nut closely and be sure that it is frm.
-
Please confirm pull flush rad press the flush valve key-press whether or not and check it is blocked or not
-
Note: Screw off pull flush rod, the cut part is upside.
-
Note: Pull flush rod should aim at the full flush key press.
-
Examination Again
Cover water tank lid and notice the following phenomenon to confirm installation complete or not: -
Open & close for water-stop washer is normal and has no leakage.
-
It is normal for full flush and half flush and they flush excellentiv.
Trouble Shooting
Symptoms
Water level is too high or too low
| Probable Reasons
Do not adjust the water level or fill valve well
| Corrective actions
Rerer to photo 5to ad]usl water level
---|---|---
/JJways water-inlet
01 do not water-inlet (for fill valve)
| 1. Switch of fill valve is dose
2. Buoy is extrusive by water tank wall
3, Filter has been blocked owing to bad water quality
|
1.0pen the fill valve S’Mtch. 2
Adjust fill valve direction.
3. Wash tilter (refer to photo3-1).
Leakage
| 1. Ftll valve nut Is loose.
2. Flush valve does not installed well
3. Pull flush rO<l Is 100 long to cling outfall well (refer to photo 7-4).
4. Flush valve body and pedestal does not match well.
5. Rerill waler Insert Into overflow mouth too deep.
| 1. Screw the fill valve nut closely.
2. lnstal flush valve- again aceotdlng toIts 1nstaUaUon step.
3. A Adjust the ad]us1ed no! (refer to photo 7•23, 4).8.Sholten the pull flush rod A is prior to a.
4. install again (refer to the installation offlush
No drainage or less drainage| Pull fluSh rods too short to press cranage pipe|
Adjust adjusted nul (refer to 7•2).
vva e, eve, ,or nannusn is too tliah or too low| Water level does not adjusted
well| Adjust water level (ref&< tophoto 6).
Installation Instructions
- Insert the hinges into the toilet.
- Tighten the screws in a clockwise direction(do not over tighten)
- Untighten the screws a bit by turning them 90° in a anti-clockwise direction this will allow you to align the seat.
- Clip on the toilet seat.
- Align the toilet seat with ceramic bowl.
- Take off the toilet seat by pressing both push buttons.
- Tighten the screws in a clockwise direction
- Place the cover over the hinges
- Clip on the toilet seat and cover.
1 | 2 X Floor brackets |
---|---|
2 | 2Xwal Iplugs S10X50 |
3 | 2X Hex head screw 6 X 60 |
4 | 2XWashers |
5 | 2XSt. Steel Screw 5X60 |
6 | 2 X Ny I on Bushes |
7 | 2 X Chrome Caps |
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>