HUUM H3100L02 Chimney Set Instructions

June 1, 2024
HUUM

HUUM H3100L02 Chimney Set

Product Specifications

Name/Quantity:

  • A Single-wall chimney 1 m
  • B Chimney base, welded
  • C Double-wall chimney 0.5 m
  • D Cover plate for penetration of sloped ceiling, double-wall
  • E Roof rafter attachment to the chimney
  • F Double-wall chimney 1 m
  • G Roof penetration, inclination 0-20 degrees
  • H Rain collar
  • I Chimney cap

Product Usage Instructions

Installation Guidelines:
Ensure a safety distance of at least 500mm between the steel chimney and any combustible materials for single-wall components (A, B), and a minimum of 50mm for double-wall components (C, F).

Assembly Steps:

  1. Start by assembling the single-wall chimney (Component A) with the chimney base (Component B).
  2. Attach the double-wall chimney (Component C) to the cover plate for sloped ceiling penetration (Component D).
  3. Connect the roof rafter attachment (Component E) to the chimney.
  4. Add the double-wall chimney extension (Component F) for additional height.
  5. Install the roof penetration piece (Component G) at an inclination of 0-20 degrees.
  6. Secure the rain collar (Component H) and chimney cap (Component I) for weather protection.

FAQs:

  • Q: What is the recommended safety distance for single-wall components?
    A: The recommended safety distance for single-wall components A and B is at least 500mm from any combustible materials.

  • Q: How should I install the roof penetration piece?
    A: The roof penetration piece (Component G) should be installed with an inclination of 0-20 degrees to ensure proper ventilation.

Parts Description

HUUM-H3100L02-Chimney-Set-Fig-1

  Name/Quantity
A Single-wall chimney 1 m
B Chimney base, welded
C Double-wall chimney 0.5 m
D Cover plate for penetration of sloped ceiling, double-wall
E Roof rafter attachment to the chimney
F Double-wall chimney 1 m
G Roof penetration, inclination 0-20 degrees
H Rain collar
I Chimney cap

Please ensure that there is a safety distance of at least 500mm between the steel chimney and any combustible materials for single-wall components (A, B), and a minimum of 50mm for double-wall components (C, F).