  • Model: Wall Mounted Air Conditioner
  • Part No.: 9387858099-02
  • Gas Type: Fluorinated Greenhouse Gases
  • Room Size Recommendations:
    • Minimum room size: 1.22m²
    • Maximum room size: 4.0m² (as per IEC 60335-2-40)
Precautions

Before using this product, read these instructions thoroughly and keep this manual for future reference. The manual contains crucial safety warnings and instructions.

Safety Warnings

  • Indicates the risk of death or serious injury.
  • Indicates the risk of personal injury or material damage.
  • Indicates prohibited actions.
  • Indicates mandatory actions.

Attention
The manual should be read carefully. Only authorized technical personnel should handle the appliance, referring to the installation manual.

Warning
The product contains fluorinated greenhouse gases. Detailed information is provided in the manual, including the minimum room dimensions required for the air conditioner’s refrigerant quantity.

Product Usage Instructions

Safety Precautions
Before operating the air conditioner, ensure to read and follow all safety precautions outlined in the manual to prevent any accidents or damage.

Preparation
Check that the following accessories are included before proceeding with the installation:

  • Remote control
  • Remote control holder
  • Self-tapping screws
  • Batteries
  • Air cleaning filters
  • Air cleaning filter supports

Parts Overview
Understand the different parts of the air conditioner, including:

  • Air intake grille
  • Air filter and cleaning filter
  • Front panel
  • Specification label
  • Drainage flexible tube
  • Horizontal airflow direction fins
  • Remote control signal receiver

Note:
Ensure the air intake grille is fully closed before powering on the unit for optimal performance.

Part Names
Descriptions of the air conditioner’s internal unit, remote control, and other components are detailed, including notes on ensuring the air intake grille is closed properly before operation.

Base Operations

Instructions are provided for starting the unit, selecting the mode, and setting the desired temperature, with a reference to temperature setting intervals.

Airflow Settings
How to adjust the fan speed and direction of airflow, including horizontal airflow direction setting and the corresponding settings for different operating modes such as cooling, dehumidification, heating, and fan.

Timer Function
Explanation of setting the timer, including weekly, on/off, and sleep timers, with steps for each timer setting procedure and examples of weekly timer settings.

Additional Operations
Instructions on activating special functions like Economy mode, powerful operation, low noise operation of the external unit, and 10°C heat operation.

Installation Settings
Details on setting the personalized code of the remote control and the steps to reset it after cleaning the air filters.

Cleaning and Maintenance

Guidelines for cleaning the internal unit, air filters, and replacing specific filters like the catechin filter and ion deodorizing filter. Frequency of cleaning and replacement is also provided.

General Information
Information about heating performance, automatic defrost function, automatic restart function, and troubleshooting tips for malfunctions caused by other electrical appliances.

Optional Components
Description of optional components such as the wired remote control, group control, and WLAN command, including WLAN adapter settings for mobile app configuration.

Frequently Asked Questions (FAQ)

What should I do if the air conditioner is not cooling effectively?

Check and clean the air filters regularly as clogged filters can reduce cooling efficiency. Also, ensure proper insulation around windows and doors in the room.

How often should I schedule maintenance for the air conditioner?

It is recommended to have professional maintenance checks at least once a year to ensure optimal performance and longevity of the unit.

Can I install the air conditioner myself?

For safety and warranty reasons, it is advised to have a qualified technician install the air conditioner following the manufacturer's guidelines.

What should I do if the air conditioner doesn't start?

Ensure the power supply is connected, check if the timer settings are correct, and verify if direct sunlight or open windows are affecting the unit.

What can cause noises during operation?

Noises can be caused by various factors, including absorbed odors from the environment, rapid cooling condensation, or low batteries in the remote control.

What maintenance should be done after prolonged disuse?

After a long period without use, it's recommended to clean the filters and check the unit before starting.

How do I reset the filter indicator?

After cleaning the air filter, reset the filter indicator by pressing the specific button on the internal unit for 2 seconds or less.

How can I troubleshoot WLAN connection issues?

Consult the WLAN adapter instruction manual or the mobile app installed on your smartphone or tablet for troubleshooting steps.