Fujitsu ASY35MI-KE Air Conditioner Instruction Manual
- June 1, 2024
- FUJITSU
Table of Contents
Fujitsu ASY35MI-KE Air Conditioner
Product Information
Specifications
- Model: Wall Mounted Air Conditioner
- Part No.: 9387858099-02
- Gas Type: Fluorinated Greenhouse Gases
- Room Size Recommendations:
- Minimum room size: 1.22m²
- Maximum room size: 4.0m² (as per IEC 60335-2-40)
Precautions
Before using this product, read these instructions thoroughly and keep this manual for future reference. The manual contains crucial safety warnings and instructions.
Safety Warnings
- Indicates the risk of death or serious injury.
- Indicates the risk of personal injury or material damage.
- Indicates prohibited actions.
- Indicates mandatory actions.
Attention
The manual should be read carefully. Only authorized technical personnel
should handle the appliance, referring to the installation manual.
Warning
The product contains fluorinated greenhouse gases. Detailed information is
provided in the manual, including the minimum room dimensions required for the
air conditioner’s refrigerant quantity.
Product Usage Instructions
Safety Precautions
Before operating the air conditioner, ensure to read and follow all safety
precautions outlined in the manual to prevent any accidents or damage.
Preparation
Check that the following accessories are included before proceeding with
the installation:
- Remote control
- Remote control holder
- Self-tapping screws
- Batteries
- Air cleaning filters
- Air cleaning filter supports
Parts Overview
Understand the different parts of the air conditioner, including:
- Air intake grille
- Air filter and cleaning filter
- Front panel
- Specification label
- Drainage flexible tube
- Horizontal airflow direction fins
- Remote control signal receiver
Note:
Ensure the air intake grille is fully closed before powering on the unit
for optimal performance.
Part Names
Descriptions of the air conditioner’s internal unit, remote control, and
other components are detailed, including notes on ensuring the air intake
grille is closed properly before operation.
Base Operations
Instructions are provided for starting the unit, selecting the mode, and setting the desired temperature, with a reference to temperature setting intervals.
Airflow Settings
How to adjust the fan speed and direction of airflow, including horizontal
airflow direction setting and the corresponding settings for different
operating modes such as cooling, dehumidification, heating, and fan.
Timer Function
Explanation of setting the timer, including weekly, on/off, and sleep timers,
with steps for each timer setting procedure and examples of weekly timer
settings.
Additional Operations
Instructions on activating special functions like Economy mode, powerful
operation, low noise operation of the external unit, and 10°C heat operation.
Installation Settings
Details on setting the personalized code of the remote control and the steps
to reset it after cleaning the air filters.
Cleaning and Maintenance
Guidelines for cleaning the internal unit, air filters, and replacing specific filters like the catechin filter and ion deodorizing filter. Frequency of cleaning and replacement is also provided.
General Information
Information about heating performance, automatic defrost function,
automatic restart function, and troubleshooting tips for malfunctions caused
by other electrical appliances.
Optional Components
Description of optional components such as the wired remote control, group
control, and WLAN command, including WLAN adapter settings for mobile app
configuration.
Frequently Asked Questions (FAQ)
What should I do if the air conditioner is not cooling effectively?
Check and clean the air filters regularly as clogged filters can reduce cooling efficiency. Also, ensure proper insulation around windows and doors in the room.
How often should I schedule maintenance for the air conditioner?
It is recommended to have professional maintenance checks at least once a year to ensure optimal performance and longevity of the unit.
Can I install the air conditioner myself?
For safety and warranty reasons, it is advised to have a qualified technician install the air conditioner following the manufacturer's guidelines.
What should I do if the air conditioner doesn't start?
Ensure the power supply is connected, check if the timer settings are correct, and verify if direct sunlight or open windows are affecting the unit.
What can cause noises during operation?
Noises can be caused by various factors, including absorbed odors from the environment, rapid cooling condensation, or low batteries in the remote control.
What maintenance should be done after prolonged disuse?
After a long period without use, it's recommended to clean the filters and check the unit before starting.
How do I reset the filter indicator?
After cleaning the air filter, reset the filter indicator by pressing the specific button on the internal unit for 2 seconds or less.
How can I troubleshoot WLAN connection issues?
Consult the WLAN adapter instruction manual or the mobile app installed on your smartphone or tablet for troubleshooting steps.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>