DASHING ON OLED
Dashing on the OLED display is a feature of the T1 Tomahawk to prevent showing
an incorrect measurement on the display. Seeing dashes is a normal part of the
T1 operation and part of the robust error-checking redundancy features built
into the T1 encoding system.
Dashing may appear during initial start-up, routine use, or other conditions.
To relocate the position on the T1, slowly extend and retract the tape measure
blade. The T1 will quickly locate where it is and display a measurement on the
screen.
NOTE: Slowly extend and/or retract the tape measure blade to allow the T1 to locate its position.
AUTOLOCK
By default the tape blade will not retract unless the Autolock button is depressed. The user can enable / disable this feature by sliding the Autolock selection slider upwards / downwards as shown.
SETUP
DIAGRAM
OLED – QUICK ACTIONS
The Quick Actions Menu on the T1 gives you access to helpful settings that you can enable / disable as needed.
E-PAPER DISPLAY
QUICK ACTIONS NAVIGATION
TOGGLE MEASURE FRONT/BACK
The T1 can measure either from the front reference surface or from the back of the T1. Measuring from the back allows the T1 to capture internal measurements effortlessly.
NOTE: To confirm that you are using the MEASURE BACK Quick Action, look for the bracket on the right side of the OLED Display. No bracket means you are in the default mode using MEASURE FRONT Quick Action.
TOGGLE RELATIVE
The T1 can toggle between absolute measurements (how much of the tape blade is extended) or relative measurements (user selects a “0” position at any point along the tape measure).
NOTE: To confirm that you are using the TOGGLE RELATIVE Quick Action, look for the bracket on the left side of the OLED Display.
SHOW CENTER
The T1 can display the center of a given measurement.
NOTE: To confirm that you are using the SHOW CENTER Quick Action, look for the two arrows in the middle of the OLED Display.
CREATE GROUP
Quickly create groups to further organize saved measurements. Groups are automatically imported as tags in the ROCK Jobsite App.
LAYOUT GUIDE
Layout Guide shows multiples of the currently selected measurements on the E-Paper Display. For example, if you select a 5 inch measurement, the T1 OLED blinks when you reach 5, 10, 15, and 20 inches.
CHARGING THE T1 BATTERY
The T1 is powered by the b1 rechargeable battery pack. To charge the battery of your T1, slide up the Battery Lid located at the back of the device and connect a USB-C cable to a source of at least 1 amp. The T1 takes approximately 2 hours to charge fully, depending on the power source.
ROCK JOBSITE APP
With the ROCK Jobsite App, the T1 Tomahawk can send measurements and other data over Bluetooth to any mobile device. The ROCK Jobsite App allows for streamlined measurement organization, sharing, calculations, and other common jobsite functions, all in a centralized, easy to use, mobile application.
Visit: https://reekon.xyz/rock to download the app. (available on both iOS and Android)https://apps.apple.com/ca/app/rock- jobsite/id1637132313https://play.google.com/store/apps/details?id=com.reekonrock.prod
MAINTENANCE OF YOUR T1
There are several adjustable, repairable, and replaceable components of the
T1. This includes:
– Tape Measure Blade
– Tape Measure Spring
– Display Protectors
– Reader Module
– Green Laser Module
For complete, step-by-step instructions, go to support.reekon.tools
USER SAFETY
⚠ WARNING: To reduce the risk of injury, the user must carefully read the
T1 QUICK START GUIDE. The person responsible for the T1 must ensure that all
users understand and comply with the instructions.
⚠ WARNING: Tape blade is electrically conductive. Do not use near bare
wires.
INTENDED USE
DO NOT use under wet conditions or in the presence of flammable liquids or
gases. DO NOT replace any component of the T1 Tomahawk with a component that
is not supplied by REEKON Tools. DO NOT store or use the tool in locations
where the temperature may exceed 104 °F (40°C) or drop below 5°F (-15 °C).
Best use in relative humidity conditions of 8% to 80% non-condensing and
altitudes no higher than 9,842ft (3,000 m). For best performance operation of
the device should take place in cool, dry conditions.
FCC COMPLIANCE
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. The device has been evaluated to meet general RF exposure requirement. The device can be used with minimum distance 0mm between the radiator and your body.
ISED CANADA COMPLIANCE
This radio transmitter has been approved by ISED Canada. This Class B digital
apparatus complies with Canadian standard ICES-003. This device complies with
ISED Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference, that may
cause undesired operation of the device.
This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. The device has been evaluated to meet general RF exposure requirement. The device can be used with minimum distance 0mm between the radiator and your body.
TECHNICAL ASSISTANCE & REPAIR
For questions about applications, technical support, repair or more
information, please see our website: https://www.reekon.tools