Scope
This document specifies the requirements and methods for the use and maintenance of BS-FC24A-300-A1ES micro-nano fiber optic gyroscope (product for short).
References and Standards
GJB1649-1993: ESD Control Program for Electronic Products
Definitions
None.
Product introduction
Product Overview
BS-FC24A-300-A1ES micro-nano fiber optic gyroscope (hereinafter referred to as
this
product) is an angular rate sensor integrating optics with analog output,
mechanics and electronics. It is based on the Sagnac effect, integrates a
variety of micro-nano fiber devices, and realizes the detection process by
detecting, processing and feeding back the phase difference generated by two
beams of light propagating in opposite directions.
This product is mainly composed of optical path components, circuit components and structural components. It has the characteristics of simple structure, no moving parts, no wear parts, fast start, small size, light weight and so on. And can be apply to that attitude control and measurement of the car
Composition
The product is mainly composed of the following components:
- A) an optical path assembly;
- B) Detection and control signal circuit board;
- C) Optical fiber ring skeleton, shell and other structural parts;
Dimensions
- φ24mm×51.6mm (standard version) d24.4 x 51.6 mm is available as a customized version – cost and lead time may vary
**Fig. 1 Outline drawing of BS-FC24A-300-A1ES micro-nano fiber optic gyroscope
**
Weight ≤30g。
Operating temperature -40℃~+65℃。
Storage temperature -55℃~+85℃。
Random vibration
Random vibration level: 20g, frequency range: 20Hz ~ 2000Hz.
Main performance parameters
Table 1 Main Performance Parameters
1 | Input range (°/s) | ±300 |
---|---|---|
2 | Scale factor (mv/o/s) | 7 + 0.7 |
3 | Bias stability (10s,1σ,°/h) | ≤2 |
4 | Bias repeatability (1σ,°/h) | ≤2 |
5 | Random walk(°/h1/2) | ≤0.02 |
6 | Bias offset(10s,1σ) | ≤0.05 |
7 | 3dB Band Width (Hz) | ≥450 |
8 | Zero-bias stability at full temperature (10s, 1σ, -40°C ~ + 65°C) | ≤90 |
9 | Supply voltage) | 5 + 0.15 |
10 | Power consumption) | ≤0.7 |
Mechanical and electrical interfaces
Mechanical interface
The bottom surface of the product is the mounting surface, with 3 M3 threads and external mechanical connection.
Figure 2 Installation Dimension
*d24.4 x 51.6 mm is available as a customized version – cost and lead time may vary
Power Requirements
The external power supply to the product has two circuits, and the requirements are shown in Table 2:
Table 2 External Power Supply Requirements
Voltage: 4.85V~5.15V
Ripple: 20mV
Electric current: 0.25A
Electrical interface
The BS-FC24A-300-A1ES micro-nano fiber optic gyroscope is electrically
connected to the
outside through the bonding pad, as shown in the figure. See Table 3 for the
definition of the bonding pad.
Figure 3 Node Arrangement
Table 3 Node Definition
Num | Definition |
---|---|
1 | 5V |
2 | Out- |
3 | Out+ |
4 | GND |
Note: the biased voltage of 1 V between (out- and GND) and (out+ and GND)
Installation of the product
I nstallation requirements
The user shall be responsible for the installation and disassembly of the
product. During this
process, the product shall not be impacted, and the outer surface of the
product shall not be machined.
I nspection before installation
- A) Check the appearance of the product for physical damage such as collision;
Inspection after installation
Check whether each mounting screw is secure.
Product maintenance
- A) Before the product is loaded into the carrier, it is required to electrify the product at least once a year for 3600s, and it is not required to detect the electrical parameters of the product when electrifying;
- B) After the product is loaded into the carrier, it is required to electrify the product at least once a year for 3600 s, and it is not required to detect the electrical parameters of the product when electrifying;
Common fault phenomena and troubleshooting methods
This product is in a fully sealed state, and cannot be repaired on site after
any failure of the
user, and needs to be returned to the production unit for maintenance. The
following only lists some fault phenomena that may occur other than the
product itself, see Table 5. If other technical problems occur during the use
of the product, please contact the product manufacturer.
Table 5 Common Faults and Troubleshooting
Serialnum ber| Fault symptom| Cause analysis| Exclusion
method
---|---|---|---
1| When the product is powered on, the current indication of the + 5V ammeter
is basically 0| The product is not supplied with power or the power
supplycurrent is too small| Check the power supply and power supply circuit,
and restore the power supply ofthe product
2| When the product is powered on, the current indication of the + 5V ammeter
is normal, but the computer acquisition program doesnot work.| Abnormal
acquisition system of test equipment| Check the connection cable and equipment
power supply
3| The product is powered on, and the current indication of the + 5Vammeter is
abnormal| There may be a short circuit inside the totaquipment| Check the test
equipment
Transportation and storage requirements of products
Transportation precautions
- A) Place the product in the direction shown in the packing box;
- B) When the temperature range is -40 ℃ ~ + 65 ℃, it is allowed to transport by road, railway, air and water;
- C) Ensure that the packing case is fastened to the carrier and will not move during transportation.
Storage precautions
- A) The products placed in the packing box shall be stored in the air-conditioned warehouse under the standard atmospheric pressure, and the ambient temperature is 15 ℃ ~ 35 ℃;
- B) The storage life of the product is 15 years.
Unpacking and inspection
Unpacking inspection
- A) Check the appearance of the packing case for physical damage such as collision;
- B) Electrostatic protection shall be carried out when the product is taken out.
Inspection of supporting delivery documents
- A) Product certificate;
- B ) Acceptance report of BS-FC24A-300-A1ES micro-nano fiber optic gyroscope;
- C) Instructions for use and maintenance of BS-FC24A-300-A1ES micro-nano fiber optic gyroscope (one copy for each batch).