Hexatronic TIA598 Nylon Loose Tube Cable Instructions

June 1, 2024
Hexatronic

Hexatronic TIA598 Nylon Loose Tube Cable

Hexatronic-TIA598-Nylon-Loose-Tube-Cable-Product

Product Information

Specifications:

  • Number of Fibers: 6-288
  • Primary Coated Fiber: Silica, acrylate
  • Loose Tube Material: Polybutylene terephthalate
  • Cable Design: Dry water-blocked concentric core with up to 24 tubes per cable
  • Outer Jacket Material: PA 12
  • Temperature Range: -20 to +70 degrees Celsius
  • Fiber Type: G652D; OM1; OM2; OM3
  • Wavelengths: 1310/1550/1625nm [850/1300]
  • Bending Radius: 0.36/0.23/0.27 [3.5/1.5]

Product Usage Instructions

Application:
The nylon loose-tube cable series is designed for use in termite-prone areas due to its hard outer nylon jacket protecting against termites and insects. It is suitable for installations where robust design and low attenuation are required.

Design Features:
The cables feature a dry waterblocked concentric core, and loose tube design with SZ stranded loose tubes that offer excellent performance under tensile loads. Each tube contains 12 fibres and is jacketed with black HDPE and blue Nylon sheath for protection.

Installation:

  1. Prepare the fibre by removing the outer jacket carefully.
  2. Access the fibres mid-span as needed for connections.
  3. Avoid exceeding the bending radius specified to prevent damage to the fibres.
  4. Secure the cable properly to prevent tension on the fibre during installation.

FAQ:

  • Q: What is the maximum number of fibres that the Nylon Loose Tube Cable can support?
    A: The cable can support up to 288 fibres, providing ample capacity for various network installations.

  • Q: What is the purpose of the SZ stranded loose tubes in the design?
    A: The SZ stranded loose tubes offer enhanced performance under significant tensile loads, making the cable suitable for installations where strength and durability are crucial.

Features

  • Up to 288 fibers
  • Suitable for installation in duct
  • Excellent optical performance with low-loss fibers
  • A dry cable design – easy to prepare and identify fibres
  • Fully dielectric design
  • Excellent mechanical performance
  • UV stabilised materials
  • Termite protected design

Application

The nylon loose-tube cable cable series combines robust design, ultra-low attenuation and excellent installation performance. Nylon loose tube is designed for use in termite-prone areas as the hard outer nylon jacket protects against termites and insects. The SZ-stranded loose tubes provide excellent performance even under significant tensile loads.

Design

  • The cables are based on a dry waterblocked concentric core, loose tube design with up to 24 tubes per cable.
  • The cables have one or two layers of protective SZ laid tubes made of a robust PBT compound where each tube has 12 fibres. (excluding 6f)
  • The tubes are jacketed by a black HDPE and blue Nylon sheath in compliance with AS 1049.
  • The design facilitates easy fibre preparation and mid-span access.

Product Information

  1. Primary coated fibre: Silica, acrylate
  2. Filler: Thixotropic gel
  3. Loose tube: Polybutylene terephthalate
  4. Central strength member: Glass fibre-reinforced plastic
  5. Wrapping: Water blocking yarns
  6. Inner sheath: High-density polyethylene
  7. Outer jacket: PA 12

Black fillers can replace tubes.
Ripcords are included underneath the inner sheath. CSM is up-coated in black PE where necessary Double layer design for fiber counts greater than 144

Technical Information

  • Product Color Blue sheath

  • Color Code TIA598

  • Temperature, Operation [°C] -20 to +70

  • Temperature, Storage [°C] -20 to +70

  • Temperature, Installation [°C] 0 to +50

  • Fiber Type G652D;OM1;OM2;OM3

  • Attenuation @Wavelength [nm] 1310/1550/1625 [850/1300]

  • Maximum Attenuation [dB/km] 0.36/0.23/0.27 [3.5/1.5]

  • Conformance

    • Temperature Range: IEC 60794-1-22-F1
    • Cable Bending Radius: IEC 60794-1-21-E11 A & B
    • Bending Under Tension: IEC 60794-1-21-E1
    • Tensile Force: IEC 60794-1-21-E1
    • Impact Resistance: IEC 60794-1-21-E4
    • Crush Resistance: IEC 60794-1-21-E3A
    • Torsion Resistance: IEC 60794-1-21-E7
    • Cable Aging: IEC 60794-1-21-F9
    • Water Penetration: IEC 60794-1-22-F5B
    • Materials: AS 1049
  • Marking
    The sheath is indelibly printed every metre in a contrasting colour using the inkjet Method. The marking includes the manufacturer, part number, manufacturing date, batch number and metre marking.

  • Ordering Information

    • Supplied lengths: 4 km ±5%

Other fiber types available by special order.

Technical Details

Hexatronic-TIA598-Nylon-Loose-Tube-Cable-Fig- \(2\)

Articles 20

Hexatronic-TIA598-Nylon-Loose-Tube-Cable-Fig- \(3\)

28701-OSA-F(+)-(6-288)LT 2023-10-17 2:11:35 AM www.hexatronic.com ©2023 Hexatronic Group.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hexatronic User Manuals

Related Manuals