VXSCAN ATJ-8766 Smart Electric Pump User Manual

June 1, 2024
VXSCAN

VXSCAN ATJ-8766 Smart Electric Pump

VXSCAN-ATJ-8766-Smart-Electric-Pump-product

Smart Electric Pump

Thank you for purchasing mini electric air pump. Please read this user manual carefully before using the product and keep it properly for reference.

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-1

Attention

  1. Donnot leave away from the product when using.
  2. The pump could be high temperature or utter a abnormal sound during using. Please turn it off to cool down. And donnot use it again until it becomes cool.
  3. Keep away from combustible and explosives.
  4. Avoid moisture, sand and falling.
  5. Do not store the product in a place that is too cold or hot. Since the inflator is equipped with lithium battery, do not put it into fire or discard casually.
  6. Keep it away from children.

Packing list

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-20

Specification

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-21

Instruction

0n/Off

  • Power on:
    • Press and hold the power button for 3 seconds to turn on the pump.
  • Shutdown:
    • Press and hold the power button for 3 seconds to turn off the pump.

Battery Indicator

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-3

  • Different numbers of indicators on the bar show different battery levels:
    • 3 Cells: 70%~100%
    • 2 Cells: 30%~70%
    • 1 Cells: 5%~30%
    • flash: 5% or less
    • (It is in a low battery state and needs to be charged before use)

Start Inflation and Stop Inflation

  • In the power-on state, short press the start-stop button to start the inflation and automatically stop inflation when the preset air pressure value is reached.

Charging

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-5

  • Type-C charging input 1A.
  • Use the charging cable to connect the pump and the power adapter (not included) to the pump for charging.
  • When the indicator bar is Progress bar jumps charging.
  • When the indicator bar is The progress bar is full fully charged.
  • Tips: The pump cannot be used during charging.

Connect Valve to Hose

Schrader

  • The bicycles, electric bicycles, motorcycles, and automobiles will be equipped with Schrader valve.
  • Charger: Connect the Schrader valve to the connector on the high-pressure hose to start a inflation.

Presta

Road bikes and some other bikes need to use a Presta adapter when inflation.

Inflation:

  1. Connect the Presta adapter to the connector on the high pressure hose.
  2. Unscrew the Presta cap of the tire.
  3. Connect the Presta to the connector to charge.

Ball Needle

  • Balls, such as basketballs and footballs, need to be filled with a ball needle.
  • Inflation: After pressing the ball needle and the Schrader connector firmly, insert the needle into the filling hole of the ball to Inflate.

Check The Air Pressure

  • When the pump is power-on, the gas pipe is connected to the charging
  • After the pressure detection object, the pump display Half of the figures are measured air pressure values.

DC start

  • Use the charging cable to connect the power outlet of the car cigarette lighter and the DC port of the product, and press the switch for a long time.
  • Power on, you can use the cigarette lighter to supply power to the product.

Mode Switching

Short press the working mode button to select 5 inflating scene modes, namely:

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-22

Unit Switching

  • Short press to switch the air pressure display unit.
  • Unit conversion formula: 1BAR = 14.5PSI

LED Lighting

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-14

  • After a long press , the LED lighting is turned on, and a long press again will turn it off.

Preset Pressure

  • Short press +/-: Adjust the preset air pressure value +/-0.5PSI.
  • Long press +/-: You can quickly adjust the preset air pressure value.

Note

  • The scene switching and the preset air pressure value software will be automatically saved, and the next time you use it, you only need to switch the scene, and the preset air pressure value will be automatically set.

Calibration

  • After the power is turned on, the hose is not connected to the charging object.
  • When the measured pressure value is not 0.0, press the key for 2 seconds at the same time, and the display will return to normal after it is fully illuminated.

Note: This product is reset at the factory. Due to altitude or sensor differences, when the measured air pressure value is not zero, a manual reset can improve the air pressure accuracy. Calibration is not recommended at high temperature.

Checking the Suggested Pressure

In order to ensure safety, before charging, please check the needs of the charged items by reading the instructions and other means, to avoid any injury due to explosion caused by overcharging.

Car Tire

  • The air pressure range of a car’s tires is marked on the side of the tire.
  • The charging pressure is related to the load weight. For more detailed air pressure recommendations, please refer to the manual of the relevant vehicle.

Bicycle Tire

  • The air pressure range of a bicycle tire is marked on the side of the tire.
  • The charging pressure is related to the load weight. For more detailed air pressure recommendations, please refer to the manual of the relevant vehicle.

Balls

  • The filling pressure of balls such as balls, basketballs, and volleyballs is marked around the filling holes.
  • The charging pressure is related to the load weight. For more detailed air pressure recommendations, please refer to the manual of the relevant ball.

Safety Precautions

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-18

  • When unscrewing the hose, the hose and joint will generate high temperature due to long-term work.
  • Please do not keep in contact for a long time.

Air Pressure Value of Common Products

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-23

Troubleshooting Guide

VXSCAN-ATJ-8766-Smart-Electric-Pump-fig-24

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals