KARCHER BP 1 Barrel Innovative Drum Pump Instruction Manual
- June 3, 2024
- Karcher
Table of Contents
makes a difference
BP 1 Barrel
Register and win!
www.kaercher.com/register-and-win
BP 1 Barrel Innovative Drum Pump
General information
Please read these original operating instructions and the enclosed safety instructions prior to the initial use of your device. Proceed accordingly. Keep both booklets for future reference or subsequent owners. Please keep in mind that the label “100% tested” may not be removed from the pump. If the label is removed, there will be no more warranty for the tightness of the pump.
Proper use
This appliance has been designed for use in private households and is not
intended for commercial use. The manufacturer is not responsible for any
damages that may occur on account of improper use or wrong operations. The
appliance is mainly intended to remove rainwater from collection containers.
Approved fluids
- Water with impurities up to a maximum grain size of 1mm
- Water from swimming pool (provided the dosing of additives is proper)
- Washing lye
Environmental protection
The packaging material can be recycled. Please do not place the packaging into
the ordinary refuse for disposal, but arrange for the proper recycling.
Old appliances contain valuable materials that can be recycled. Please arrange
for the proper recycling of old appliances. Please dispose your old appliances
using appropriate collection systems.
Notes about the ingredients (REACH)
You will find current information about the ingredients at:
www.kaercher.com/REACH
Warranty
The warranty terms published by the relevant sales company are applicable in
each country. We will repair potential failures of your appliance within the
warranty period free of charge, provided that such failure is caused by faulty
material or defects in manufacturing. In the event of a warranty claim please
contact your dealer or the nearest authorized Customer Service centre. Please
submit the proof of purchase.
Operation
Description of the Appliance
1. Power cord with plug
2. Drum edge holder
3. Locking valve
4. O ring
5. Housing bowl for level switch
6. Housing cover for level switch
7. Hose coupling| 8. Pressure hose
9. Hose clamp
10. Level sensor
11. Level switch attachment
12. Carrying handle
13. Hose connection G3/4 (24.4 mm) for hose coupling
---|---
Before Startup
Screw the hose connection on to the pump
Connect the hose connection to the hose coupling of the drum edge holder.
Operation
DANGER
Risk of mortal danger on account of electric shock!
Do not touch the feed fluid and the rope fastened to the carrying handle
during operation.
NOTICE
The liquid level must at least be 3 cm for the pump to suck in liquids
independently. If the prerequisites for the pump operation are met (water
level, position/level switch), the pump will start immediately after the mains
plug has been plugged in.
Comfort operation
In order to run the pump independently of the water level, the level switch
must be mounted inside the housing.
Illustration **1**
Screw the housing bowl and the O-ring onto the drum edge holder.
Place the level switch into the housing bowl.
Press the housing cover down onto the housing bowl until it locks.
Illustration **2**
Slide the drum edge holder onto the container edge until it is properly
seated.
Illustration **3**
Place the pump on a stabil surface in the liquid to be transported. Immerse it
using a rope tied to the handle or hang it into the container by the hose. The
suction area should not be blocked fully or partially through the impurities.
Illustration **4**
Close locking tap (arrow horizontal).
Insert the mains plug into the socket.
Rotate the housing with the level switch in the arrow direction “ON”.
The pump will turn on.
Open the locking tap to remove water (arrow vertical).
Automatic operation
In the automatic mode, the level switch automatically controls the pumping
operations. The pump switches on or off when the fluid level reaches the
height that has been set. Ensure that the level sensor is not obstructed in
any way.
Illustration **5**
In automatic operation, set the required switching height by clamping the
level switch cable into the stopper.
Open the locking tap to remove water (arrow vertical).
Insert the mains plug into the socket.
Manual operation
In manual operations the pump remains switched on continuously.
Illustration **6**
In manual operations mode, align the level sensor upward (cable pointing
downward). Tip: Push the cable of the level sensor like a loop through the
handle.
Open the locking tap to remove water (arrow vertical).
Insert the mains plug into the socket.
NOTICE
Dry running leads to increased wear and tear; do not leave the pump unattended
during manual operation. Switch off the pump within 3 minutes of dry running.
Finish operation
NOTICE
Soiling can deposit and lead to malfunctions.
Rinse the pump with clean water after use. This especially applies after
pumping chlorinated water or other liquids that leave residue.
Rotate the housing with the level switch in the arrow direction “OFF”. The
pump will turn off.
Disconnect the main plug from the socket.
Maintenance
The pump is maintenace-free.
Transport
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance during transport (see Specifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle secure it from slipping.
Storage
CAUTION
In order to prevent accidents or injuries, keep in mind the weight of the
appliance when selecting a storage location for it (see Specifications).
Storing the Appliance
Illustration **7**
Tip the drum edge holder forward and take out toward the top.
Completely drain the pump and allow it to dry.
Store the appliance in a frost free area.
Special accessories
2.645-193.0/
2.645-203.0| Universal hose coupling Plus, for 1/2″, 5/8″ and 3/4″ hoses|
Recessed grips made of soft plastic ensure easy handling.
Universally useable for all common garden hoses.
---|---|---
2.645-148.0| Hose PrimoFlex plus, 25 m, 3/4″| Phthalate-free 3/4″ garden hose
for connecting the pump with the application equipment.
Caution
To avoid risks, all repairs and replacement of spare parts may only be carried
out by authorized customer service personnel.
First pull out the plug from the mains before carrying out any tasks on the
machine.
Troubleshooting
Fault | Cause | Remedy |
---|---|---|
Pump runs but does not transport | Air in the pump | Plug in/ pull out the mains |
plug of the pump a few times till the fluid gets sucked
Suction area blocked| Pull out the mains plug and clean the suction area
(only in manual mode) Water level be- low the minimum water level| Immerse the
pump deeper into the liquid, if possible.
Pressure hose is blocked| Pull out the mains plug and clean the pressure hose
Locking tap is closed (arrow horizontal).| Open the locking tap (arrow
vertical).
Pump does not run or suddenly comes to a standstill during opera- tions| Power
supply interrupted| Check fuses and electrical connections
Thermal protection switch in the motor has switched off the pump as it was
overheated.| Pull out the mains plug, let the pump cool down, clean the
suction area, prevent dry running
Dirt particles have got jammed into the suction area| Pull out the mains plug
and clean the suction area
Pump operation stopped by sensor| Check position of level sensor
Pumping capacity is reducing| Suction area blocked| Pull out the mains plug
and clean the suction area
Pumping capacity too low| The pumping capacity depends on the flow height,
hose diameter, and hose length.| Keep max. flow height, see technical data. If
necessary, select a different hose diameter or hose length.
Our Kärcher branch will be pleased to help you further in the case of questions or faults. See address on the reverse.
Specifications
| | BP I Barrel
---|---|---
Voltage| V| 230 – 240
Current type| Hz| 50
Output Pnom| W| 400
Max. flow rate| I/h| 3800
Max. pressure| MPa (bar)| 0.11
(1.1)
Max. flow height| m| 11
Max. immersion depth| m| 7
Max. grain size of the dirt particles that can be transported| mm| 1
Weight| kg| 6.
Sound levels (EN 60704-1)| dB(A)| 44
Mains cable length (EN 60335-2-41)| m| 10
Subject to technical modifications!
The possible delivery rate is even larger:
- the smaller the suction and delivery heights are.
- the larger the diameter of the hoses used are.
- the shorter the hoses used are.
- the less loss of pressure is caused by the connected accessories.
http://www.kaercher.com/dealersearch
http://kaer.ch/er/?l=TwSoJtl9IUOwZyAe1rHDyw
Alfred Kärcher GmbH & Co. KG
Alfred-Kärcher-Str. 28 – 40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212
References
Read User Manual Online (PDF format)