HYDRO Taurus CP-300 Single Product Laundry Dispenser User Manual
- June 1, 2024
- HYDRO
Table of Contents
HYDRO Taurus CP-300 Single Product Laundry Dispenser
Specifications
- Pump delay time: Adjustable
- Pump run time: Adjustable
- Pump lockout time: Adjustable
- Pump rate: Variable
- Wall-mounted transformer
- Hardwired remote with 2 buttons and 3 LEDs
Product Usage Instructions
Installation
Install the wall-mounted pump and remote unit
- Attach mounting bracket to a solid surface using provided screws.
- Slide the Taurus CP-300 onto the bracket and press firmly to lock in place.
- Mount the remote unit on a clean, dry surface using the adhesive-backed fasteners.
- Connect the Taurus CP-300 to the remote using the Cat 5e cable.
Install the supply and discharge tubing
Supply Tubing
- Cut tubing and route from the product container to the intake pump tube.
- Slip tubing through compression nut into fitting and tighten.
- Place the other end of the tubing into the product container.
Discharge Tubing
- Cut tubing and route from the discharge location to the outflow pump tube.
- Slip tubing through compression nut into fitting and tighten.
Programming
Overview
The Taurus CP-300 dispenses liquid chemicals accurately. Press the START
button once to begin a cycle based on your programmed settings.
Enter Programming Mode
To enter programming mode, follow the instructions provided in the user
manual.
Programming the Start Delay Time
Adjust the start delay time as needed for your application.
Programming the Pump Run Time
Set the pump run time according to your requirements.
Programming the Pump Lockout Time
Adjust the pump lockout time based on your needs.
Programming the User Prime Feature
If applicable, set up the user prime feature following the manual
instructions.
Saving the Programmed Settings
After programming, make sure to save your settings as instructed in the
user manual.
FAQ
- Q: Can I install the Taurus CP-300 myself?
A: The CP-300 should be installed by a qualified technician only, following all electrical and plumbing codes for safety reasons.
Overview
Operation
The Taurus CP-300 dispenses liquid chemicals with a high degree of accuracy
and repeatability. A separately wired remote provides a convenient way to
start the cycle. Simple mounting, setup, and low cost make it ideal for
single-product applications. Once programmed, operation is simple. Press the
START button once (the green LED will flash once to show your button press has
been “accepted”) and the Taurus dispenser will begin a use cycle; using
whatever pump delay time, pump run time and pump lockout time you have
programmed.
General Specifications
Feature | Range |
---|---|
Pump delay time | 0 – 32 min. (15 sec doubled…) |
Pump run time | 0 – 20 min. (real time) |
Pump lockout time | 0 – 30 min. (5 min. increments) |
Pump rate | Approx. 8 ounces / minute |
Wall-mounted transformer | 24 Volt DC, 1 Amp |
Hardwired remote with 2 buttons and 3 LEDs
Hardwired remote with 2 buttons and 3 LEDs
WARNING!
The CP-300 should be installed by a qualified technician only, in accordance
with all applicable electrical and plumbing codes.
Package Contents
- Taurus CP-300 Pump, Cat 5e Cable (P/N 00-08879-00)
- Wall Mount Kit (P/N 13-08607-00)
- Wall Power Transformer, 100-240 VAC (P/N 10096229)
- Programmer Remote (P/N 13-08602-06)
- Adhesive-back Remote Fasteners (P/N 36-06158-16025)
Installation
Install the wall-mounted pump and remote unit
Install the Taurus CP-300 close to product containers (6.5 ft. / 2 m.) and
farther away from direct sources of steam, water spray, and high temperatures.
- Attach mounting bracket to solid surface (drywall, masonry, wood, cement, cinder block) with provided screws. Use appropriate hardware for the material, e.g., metal anchors in cement or cinder block.
- Slide the Taurus CP-300 down onto bracket and press firmly to lock in place.
- Mount remote unit on a clean and dry surface using the provided adhesive-backed fasteners.
- Connect the Taurus CP-300 to the remote using the Cat 5e cable as shown.
Install the supply and discharge tubing
Supply Tubing
- Cut tubing and route from product container to intake (left) pump tube. Slip tubing through compression nut into fitting and tighten.
- Place other end of tubing into the product container.
Discharge Tubing
- Cut tubing and route from discharge location to outflow (right) pump tube.
- Slip tubing through compression nut into fitting and tighten.
WARNING!
Disconnect all power to the dispenser during installation, service, and/or any
time pump cabinet is opened.
Install the wall-mounted transformer
- Plug the wall transformer into an AC outlet.
- Plug the barrel adapter into the Taurus CP-300 power connector at the bottom of pump unit.
The green LED on the pump will turn on, indicating power and the remote LEDs
will flash a code that indicates the firmware revision.
NOTE: Use only the transformer specified from the manufacturer to ensure
proper operation. Usage of transformer must conform to local laws and codes.
Prime the pump unit
- Press and hold the START button on the remote unit. After 10 seconds the pump will start. Continue to hold the Start button down to draw product into the pickup tubing.
- When the pickup tubing is free of air, release the START button to stop priming.
WARNING!
Always verify power source voltage with volt meter.
Programming
Overview
The Taurus CP-300 is programmed using the Taurus CP-300 Programmer Remote.
The remote’s two-button interface contains the following features:
The three remote LEDs indicate the pump’s state of operation as follows:
Remote LED Indicator | State of Operation |
---|---|
Green (flashes once) | Confirmation of Start Button press. |
Yellow | Pump (Dispense) Delay in progress… |
Green | Pumping (Dispensing)… |
Red | Pump (Dispense) Complete, Lockout in progress… |
(No LED lit) | Idle |
Scrolling LEDs | When Program or Start button is pressed when use cycle is in |
progress. LEDs scroll Red-Green-Yellow twice to indicate button is being ignored. Try again after use cycle finishes.
NOTE: Please refer to the following instructions for more information on LED indicator functionality.
Enter Programming Mode
The Taurus CP-300 dispenses liquid chemicals with a high degree of accuracy
and repeatability. A separately wired remote provides a convenient way to
start the cycle. Simple mounting, setup, and low cost make it ideal for
single-product applications.
Press and hold the START and PROG SELECT buttons simultaneously for 10
seconds. All three LED indicators will illuminate to confirm that programming
mode has been activated.
NOTE: Once in programming mode, pressing the PROG SELECT button will
allow you to sequence through the four programming options:
- Start Delay Time
- Run Time
- Lockout Period
- User Prime
Each of these functions is described below.
Programming the Start Delay Time
- Once in programming mode, press the PROG SELECT button once. The yellow LED indicator will illuminate.
- With the yellow LED illuminated, press the START button once for every start delay increment you wish to add. Each press is confirmed by a yellow LED flash. Please refer to the table below to determine the number of presses needed for your desired delay time increment.
Yellow LED illuminates
Start Button Presses | Delay Time (sec/min) |
---|---|
1 | 0 (No Delay) |
2 | 15 sec |
3 | 30 sec |
4 | 1 min |
5 | 2 min |
6 | 4 min |
7 | 8 min |
8 | 16 min |
9 | 32 min |
NOTE: The LED will not flash if you press START after the time limit has been met.
Programming the Pump Run Time
- Once the Start Delay Time has been programmed, press the PROG SELECT button again. The green LED indicator will illuminate.
- Press and release the START button to start the Run Time.
- The pump will turn on.
- This works like a stopwatch; you press START to begin timing the Pump Run Time. Then you press START again to stop timing the Pump Run Time.
- The green LED will flash every one second.
- A Pump Run Time can be up to 20 minutes.
- Press and release the START button again to stop the Run Time.
- The pump will turn off
- The green LED will remain on
Green LED illuminates
Programming the Pump Lockout Period
The is Pump Lockout Period can be used to prevent the press of the START
button from pumping another product dose during the same use cycle.
Red LED illuminates
- Once the Pump Run Time has been programmed, press the PROG SELECT button again. The red LED indicator will illuminate to indicate you can now program a Pump Lockout Period.
- With the red LED illuminated, press the START button once for every five-minute lock-out period you wish to add. Each press is confirmed by a red LED flash. Please refer to the table below to determine the number of presses needed for your desired time increment.
Start Button Presses | Delay Time (min) |
---|---|
1 | 0 (No Delay) |
2 | 5 min |
3 | 10 min |
4 | 15 min |
5 | 20 min |
6 | 25 min |
7 | 30 min |
NOTE: The LED will not flash when the time limit has been met (30 min).
- If, during normal operation, power to the dispenser is interrupted while in a Lockout Period, the balance of the Lockout Period will continue when power is restored.
Programming the User Prime Feature
-
Once the Pump Lockout Period has been programmed, press the PROG SELECT button again so you can program the User Prime feature.
The green and yellow LED indicators will illuminate to indicate User Prime is enabled. -
Press the START button again to disable the User Prime.
The green and red LED indicators will illuminate to indicate User Prime is disabled.
Yellow and Green LED illuminated
The Yellow and Green LEDs indicate User Prime is enabled.
The Green and Red LEDs indicate User Prime is disabled.
NOTE: In other words, the green LED indicator stays on, while the yellow
and red LED indicators toggle with each press of the START button to indicate
whether the User Prime is enabled or disabled.
The User Prime feature, during normal operation, allows the operator to hold
the START button down for 10 seconds to start the pump manually. The pump will
continue to run while the START button is held down, and stop when the START
button is released.
Saving the Programmed Settings
Red and Green LED illuminated
To exit programming mode and save the settings, press and hold the PROG SELECT button first, then press and hold the START button for 2 seconds.
- All three LED indicators will illuminate to indicate the programmed settings have been saved
- A program review will be conducted as follows:
Program Feature | Review Indication |
---|---|
Start Delay Time | The yellow LED will turn on and flash for each delay |
increment for which the Start Delay Time was programmed. No flash indicates no
Start Delay Time.
Pump Run Time| The green LED will use a long flash for each number of minutes,
followed by quick flashes for each second for which the Pump Run Time was
programmed.
Lockout Period| The red LED will turn on and flash for each five- minute
increment for which the Lockout Period was programmed. No flash indicates 0
Lockout Period.
User Prime| The green and yellow LED indicators will illuminate if the User
Prime is enabled. The green and red LED indicators will illuminate if the
User Prime is disabled
NOTES:
- To exit programming mode without saving the settings, allow 20 seconds to lapse without pressing any buttons.
- To restore factory defaults, press and hold the START button and the PROG SELECT button simultaneously for ten seconds while powering up the unit. All three LED indicators will flash on and off twice to confirm that factory defaults have been restored.
Service Parts
Exploded Parts Diagram
Service Part Numbers
Reference | Part # | Description |
---|---|---|
1 | 13-08706-06 | Pump Cover, Teal (thumb-screw included) |
2 | 13-06396-00 | Pump Spinner |
3 | 13-06399-10 | Pump Tube, Standard, 1/4“ Compression, Detergent, EPDM, 10-pk. |
13-06395-10 | Pump Tube, 1/4“ Compression, Rinse, EPDM, 10-pk. | |
13-06395-30 | Pump Tube, 1/8“ Compression, Rinse, EPDM, 10-pk. | |
4 | 13-08721-01 | Pump Motor Kit (Detergent) |
5 | 10096229 | Wall-mounted Transformer, 24 VDC, 1 Amp |
6 | 13-08602-06 | Taurus CP-300 Programmer Remote, Black |
Specifications and Warranty Specifications
Size | 3” W x 4.5” H x 4.5” D (7.6 cm. W x 11.4 cm. H x 11.4 cm. D) |
---|---|
Weight | 1.8 lb. (.82 kg.) |
Power Rating | 24 VDC 1 Amp |
Flow Rate | 8 oz. (237 ml.) / minute with standard Detergent tube |
Run Time | 0 – 20 minutes |
Duty Cycle | 66%, 20 minute maximum run time |
**** Environmental Specifications | |
IP, Pollution, Installation | IP Rating : 44 Pollution Category: 2 |
Installation Category: 2
Temperature| 10° to 49° C (50° to 120° F) maximum
Humidity| 95% relative humidity, maximum
Indoor Installation| Approved for indoor use only. Must not be installed
outdoors.
Specifications subject to change without notice.
Limited Warranty
Seller warrants solely to Buyer the Products will be free from defects in
material and workmanship under normal use and service for a period of one year
from the date of completion of manufacture. This limited warranty does not
apply to (a) hoses; (b) and products that have a normal life shorter than one
year; or (c) failure in performance or damage caused by chemicals, abrasive
materials, corrosion, lightning, improper voltage supply, physical abuse,
mishandling or misapplication. In the event the Products are altered or
repaired by Buyer without Seller’s prior written approval, all warranties will
be void. No other warranty, oral, express or implied, including any warranty
of merchantability or fitness for any particular purpose, is made for these
products, and all other warranties are hereby expressly excluded. Seller’s
sole obligation under this warranty will be, at Seller’s option, to repair or
replace F.O.B. Seller’s facility in Cincinnati, Ohio any Products found to be
other than as warranted.
Limitation of Liability
Seller’s warranty obligations and Buyer’s remedies are solely and exclusively
as stated herein. Seller shall have no other liability, direct or indirect, of
any kind, including liability for special, incidental, or consequential
damages or for any other claims for damage or loss resulting from any cause
whatsoever, whether based on negligence, strict liability, breach of contract
or breach of warranty.
Hydro Systems
3798 Round Bottom Road Cincinnati, OH 45244
- Phone 513.271.88OO
- Toll Free 8OO.543.7184
- Fax 513.271.O16O
- Web hydrosystemsco.com