Product Information

Specifications

  • Model Version: S21 Hyd. m0-10
  • Crypto algorithm/coins: SHA256|BTC/BCH
  • Typical Hashrate: 335 TH/s
  • Power on wall @35: 5360 Watt
  • Power efficiency on wall@35: 16.0 J/TH

Detailed Characteristics

  • Power supply:

    • AC input voltage: 380~415V AC
    • AC Input Frequency Range: 50~60 Hz
    • AC Input current: 12 Amp
  • Hardware configuration:

    • Network connection mode: RJ45 Ethernet
      10/100M

    • Server size (LengthWidthHeight, w/o
      package):
      339163207 mm

    • Server size (LengthWidthHeight, with
      package):
      570316430 mm

    • Net weight: 12.3 kg

    • Gross weight: 13.6 kg

  • Environment requirements:

    • Fluid type: Deionized water/Pure water
    • Water conductivity: 8.5~9.5 DN10
    • Operating temperature: -20~70°C
    • Operating humidity: 10~90%

Product Usage Instructions

  1. Initial Setup
    • Ensure the power supply is connected to the specified AC input voltage range.
    • Connect the network cable using RJ45 Ethernet to establish a connection.
  2. Operating Modes
    • NEM: Hashrate at 35 TH/s, Power on wall at 5360 Watt.
    • HEM1: Hashrate at 45 TH/s, Power on wall at 5890 Watt.
    • HEM2: Hashrate at 50 TH/s, Power on wall at 5960 Watt.
  3. Maintenance
    • Monitor water conductivity and ensure it remains between 8.5 to 9.5 DN10.
    • Replace the fluid if water conductivity exceeds the specified limit.

Frequently Asked Questions (FAQ)

  • Q: What should I do if the product cannot be started?
    A: Check the power supply connection and ensure it is within the specified voltage range. If the issue persists, contact customer support.

  • Q: How often should I replace the fluid in the system?
    A: If the water conductivity exceeds 100 s/cm or as indicated in the manual, replace the fluid promptly to maintain optimal performance.

S21 Hyd.
Product Manual

Specification

Product Glance Value
Model [S21 Hyd.](https://www.zeusbtc.com/Asic-Miner/Asic-Miner-

Details.asp?ID=3168)
Version| m0-10
Crypto a lgorithm/coins| SHA256|BTC/BCH
Typical Hashrate, TH/s(1-1)| 335
Power on wall @35τ(1-2), Watt(1-1)| 5360
Power efficiency on wall@35τ(1-2), J/TH(1-1)| 16.0
Detailed Characteristics| Value
---|---
Power supply
Power supply AC input voltage, Volt(2-1)| 380~415V AC
Powersupply AC Input Frequency Range, Hz| 50~60
Power supply AC Input current, Amp(2-2)| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 339163207
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 12.3
Gross weight, kg| 13.6
Environment requirements
Inlet water temperature, °C| NEM(2-3)| 35
HEM1(2-4)| 45
HEM2(2-4)| 50
Water flow, L/min| 8.0~10.0
Water pressure bar| ≤3.5
Working fluid(2-5)| Deionized water/Pure water
Liquid PH| 8.5~9.5
Diameter of water pipe connector, mm| DN10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%

Notes:

  1. The Hashrate value, Power on wall, and Power efficiency on wall are all typical values. The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
  2. Inlet water temperature.
  3. Caution: Wrong input voltage may cause server damaged.
  4. Three-phase AC input, 10 A per wire.
  5. NEM: Normal EnergyMode. If the inlet water temperature is lower than 20 °C, the miner cannot be started.
  6. HEM: High EnergyMode.
  7. If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.

Working Mode

Working Mode NEM HEM1 HEM2
Inlet water temperature, °C(3-1) 35 45 50
Hashrate, TH/s 335 335 335
Power on wall, Watt 5360 5890 5960
Power efficiency on wall, J/TH 16.0 17.6 17.8

Notes:

  1. For the external dry cooler (EC2-DT),
    • if the outlet water temperature is 35°C, the maximum ambient temperature is 30°C;
    • if the outlet water temperature is 45°C, the maximum ambient temperature is 40°C;
    • if the outlet water temperature is 50°C, the maximum ambient temperature is 45°C.