m0-10 Power Supply Mining PSU For Bitmain Antminer Instruction Manual
- June 1, 2024
- ANTMINER
Table of Contents
m0-10 Power Supply Mining PSU For Bitmain Antminer
Product Information
Specifications
- Model Version: S21 Hyd. m0-10
- Crypto algorithm/coins: SHA256|BTC/BCH
- Typical Hashrate: 335 TH/s
- Power on wall @35: 5360 Watt
- Power efficiency on wall@35: 16.0 J/TH
Detailed Characteristics
-
Power supply:
- AC input voltage: 380~415V AC
- AC Input Frequency Range: 50~60 Hz
- AC Input current: 12 Amp
-
Hardware configuration:
-
Network connection mode: RJ45 Ethernet
10/100M -
Server size (LengthWidthHeight, w/o
package): 339163207 mm -
Server size (LengthWidthHeight, with
package): 570316430 mm -
Net weight: 12.3 kg
-
Gross weight: 13.6 kg
-
-
Environment requirements:
- Fluid type: Deionized water/Pure water
- Water conductivity: 8.5~9.5 DN10
- Operating temperature: -20~70°C
- Operating humidity: 10~90%
Product Usage Instructions
- Initial Setup
- Ensure the power supply is connected to the specified AC input voltage range.
- Connect the network cable using RJ45 Ethernet to establish a connection.
- Operating Modes
- NEM: Hashrate at 35 TH/s, Power on wall at 5360 Watt.
- HEM1: Hashrate at 45 TH/s, Power on wall at 5890 Watt.
- HEM2: Hashrate at 50 TH/s, Power on wall at 5960 Watt.
- Maintenance
- Monitor water conductivity and ensure it remains between 8.5 to 9.5 DN10.
- Replace the fluid if water conductivity exceeds the specified limit.
Frequently Asked Questions (FAQ)
-
Q: What should I do if the product cannot be started?
A: Check the power supply connection and ensure it is within the specified voltage range. If the issue persists, contact customer support. -
Q: How often should I replace the fluid in the system?
A: If the water conductivity exceeds 100 s/cm or as indicated in the manual, replace the fluid promptly to maintain optimal performance.
S21 Hyd.
Product Manual
Specification
Product Glance | Value |
---|---|
Model | [S21 Hyd.](https://www.zeusbtc.com/Asic-Miner/Asic-Miner- |
Details.asp?ID=3168)
Version| m0-10
Crypto a lgorithm/coins| SHA256|BTC/BCH
Typical Hashrate, TH/s(1-1)| 335
Power on wall @35τ(1-2), Watt(1-1)| 5360
Power efficiency on wall@35τ(1-2), J/TH(1-1)| 16.0
Detailed Characteristics| Value
---|---
Power supply
Power supply AC input voltage, Volt(2-1)| 380~415V AC
Powersupply AC Input Frequency Range, Hz| 50~60
Power supply AC Input current, Amp(2-2)| 12
Hardware configuration
Network connection mode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 339163207
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 12.3
Gross weight, kg| 13.6
Environment requirements
Inlet water temperature, °C| NEM(2-3)| 35
HEM1(2-4)| 45
HEM2(2-4)| 50
Water flow, L/min| 8.0~10.0
Water pressure bar| ≤3.5
Working fluid(2-5)| Deionized water/Pure water
Liquid PH| 8.5~9.5
Diameter of water pipe connector, mm| DN10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%
Notes:
- The Hashrate value, Power on wall, and Power efficiency on wall are all typical values. The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
- Inlet water temperature.
- Caution: Wrong input voltage may cause server damaged.
- Three-phase AC input, 10 A per wire.
- NEM: Normal EnergyMode. If the inlet water temperature is lower than 20 °C, the miner cannot be started.
- HEM: High EnergyMode.
- If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cm when the system is running at the first time.
Working Mode
Working Mode | NEM | HEM1 | HEM2 |
---|---|---|---|
Inlet water temperature, °C(3-1) | 35 | 45 | 50 |
Hashrate, TH/s | 335 | 335 | 335 |
Power on wall, Watt | 5360 | 5890 | 5960 |
Power efficiency on wall, J/TH | 16.0 | 17.6 | 17.8 |
Notes:
- For the external dry cooler (EC2-DT),
- if the outlet water temperature is 35°C, the maximum ambient temperature is 30°C;
- if the outlet water temperature is 45°C, the maximum ambient temperature is 40°C;
- if the outlet water temperature is 50°C, the maximum ambient temperature is 45°C.