ANTMINER 208-A Bitcoin Miner User Manual

June 1, 2024
ANTMINER

ANTMINER 208-A Bitcoin Miner

ANTMINER-208-A-Bitcoin-Miner-PRODUCT

Specifications

  • Model: S19 Pro Hyd. 208-A
  • Crypto algorithm/coins: SHA256|BTC/BCH
  • Typical Hashrate: 184 TH/s
  • Power on wall @35: 5428 Watt
  • Power efficiency on wall@35: 29.5 J/TH

Power supply:

  • AC input voltage: 380~415V AC
  • AC Input Frequency Range: 50~60 Hz
  • AC Input current: 12 Amp

Hardware configuration:

  • Network connection mode: RJ45 Ethernet
    10/100M

  • Server size (LengthWidthHeight, w/o
    package):
    336175.5208 mm

  • Server size (LengthWidthHeight, with
    package):
    570316430 mm

  • Net weight: 13.0 kg

  • Gross weight: 15.6 kg

Environment requirements:

  • Liquid: Deionized water/Pure water
  • pH: 8.5~9.5
  • Diameter of water pipe connector: DN10 mm
  • Temperature: -20~70°C
  • Humidity: 10~90%

Product Manual

Nov. 2023

Specification

Product Glance Value
Model [S19 Pro Hyd.](https://www.zeusbtc.com/Asic-Miner/Asic-Miner-

Details.asp?ID=3113)
Version| 208-A
Cryptoalgorithm/coins| SHA256|BTC/BCH
Typical Hashrate, TH/s(1-1)| 184
Power on wall @35τ(1-2), Watt(1-1)| 5428
Power efficiency on wall@35τ(1-2), J/TH(1-1)| 29.5
Detailed Characteristics| Value
---|---
Power supply
Power supply AC input voltage, Volt(2-1)| 380~415V AC
Powersupply AC Input Frequency Range, Hz| 50~60
Power supply AC Input current, Amp(2-2)| 12
Hardware configuration
Networkconnectionmode| RJ45 Ethernet 10/100M
Server size (LengthWidthHeight, w/o package), mm| 336175.5208
Server size (LengthWidthHeight, with package), mm| 570316430
Net weight, kg| 13.0
Gross weight, kg| 15.6
Environment requirements
Inlet water temperature, °C| 35
Water flow, L/min| 8.0~10.0
Water pressure bar| ≤3.5
Working fluid(2-3)| Deionized water/Pure water
Liquid PH| 8.5~9.5
Diameter of water pipe connector, mm| DN10
Storage temperature, °C| -20~70
Operation humidity(non-condensing), RH| 10~90%

Notes

  1.  The Hashrate value, Power on wall, and Power efficiency on wall are all typical values. The actual Hashrate value fluctuates by ±3%, and the actual Power on wall and Power efficiency on wall fluctuate by ±5%.
  2. Inlet water temperature.
  3. Caution: Wrong input voltage may cause server damaged.
  4. Three-phase AC input, 10 A per wire.
  5.  If the water conductivity is ≥100 μs/cm, the fluid must be replaced. The water conductivity is less than 20 μs/cmwhen the systemis running atthe first time.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ANTMINER User Manuals

Related Manuals