Sunco PN22_TR_DU-WH-3550K LED Center Basket Troffer User Manual
- June 1, 2024
- SUNCO
Table of Contents
- Sunco PN22_TR_DU-WH-3550K LED Center Basket Troffer
- Product Usage Instructions
- Frequently Asked Questions
- Whats in the Box
- Before You Start
- Wiring Diagram
- Installation
- Product Details
- Specifications
- Troubleshooting
- Light Distribution Angle
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Sunco PN22_TR_DU-WH-3550K LED Center Basket Troffer
Specifications
- Voltage: Standard voltage
- Wattage: 20W, 30W, 40W
- Power Factor: Not specified
- Beam Angle: Not specified
- CCT: 3500K, 4000K, 5000K
- Housing Material: Not specified
- Dimmable: Yes, compatible with recommended dimmers
Product Details
Recommended Dimmers:
Brand | Model |
---|---|
LUTRON | DVSTV |
LUTRON | NTSTV-DV |
Product Usage Instructions
Installation Guide (Recessed Mount)
-
1. **STEP 1:**
-
* Turn off circuit breaker before installation.
- Place Ceiling Panel face down on a flat surface.
- Unscrew 1 driver cover and set aside screws.
-
Installation Guide (Suspension Mount)
-
1. **STEP 1:**
-
* Turn off circuit breaker before installation.
- Place Ceiling Panel face down on a flat surface.
- Unscrew 1 driver cover and set aside screws.
-
Frequently Asked Questions
Q: Is the product suitable for outdoor use?
A: No, this product is designed for indoor use only.
Whats in the Box
Ceiling Panel
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury
- Turn off circuit breaker before installing this fixture.
- Suitable for use in wet environments at temperatures ranging from -4° to 113°.
- Not for use where directly exposed to water.
- Not intended for use with emergency fixtures.
- Not compatible with photo controls.
- Not compatible with occupancy sensors.
- Not compatible with third party sensors.
- Not compatible with all dimmers. For more dimming information, please visit www.sunco.com.
- Not compatible with timing devices.
- All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards.
- Please review installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.
WARNING:
Cancer & Reproductive Harm- www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Wiring Diagram
Installation
Installation Guide (Recessed Mount)
STEP 1
- a. Turn off circuit breaker before installation.
- b. Place Ceiling Panel face down on flat surface. Unscrew 1 driver covers and set aside screws. Pop out knockout (choice of 3).
- c. Optional: if using dimmer, pop out 2nd knockout
STEP 2
-
a. Use switches to choose CCT and brightness settings:
Brightness CCT- 20W -3500K
- 30W -4000K
- 40W -5000K
-
b. Connect conduit to each knockout. Feed wires through.
STEP 3
- a. Connect supply and junction wires using wire nuts. Black to Black
- (Live): White to White (Neutral): Green to Green (Ground). Optional: To use dimming feature, connect pink and purple wires onCeiling Panel to compatible dimmer (not included).
STEP 4
- a. Replace drive covers. Tighten screws.
- b. Bend 2 protective brackets located on back of Ceiling Panel up 90o.
STEP 5
- a. Turn brackets 90o. Hook should face outside edge of Ceiling Panel.
STEP 6
- a. Turn on circuit breaker and test light.
Installation Guide (Suspension Mount)
STEP 1
- a. Turn off circuit breaker before installation.
- b. Place Ceiling Panel face down on flat surface. Unscrew 1 driver covers and set aside screws. Pop out knockout (choice of 3).
- c. Optional: If using dimmer, pop out 2nd knockout.
STEP 2
- a. Use switches to choose CCT and brightness settings:
- Brightness CCT
- 20W -3500K
- 30W -4000K
- 40W -5000K
- b. Connect conduit to each knockout. Feed wires through.
STEP 3
- a. Connect supply and junction wires using wire nuts. Black to Black (Live): White to White (Neutral): Green to Green (Ground).
STEP 4
- Optional: To use dimming feature, connect pink and purple wires on Ceiling Panel to compatible dimmer (not included).
STEP 5
- a. Replace drive covers. Tighten screws. Drill 2 holes into ceiling.
- b. Place anchors into hole, insert wire rope, and screw.
- Refer to suspension kit’s (not included) install manual for complete details.
STEP 6
- a. Adjust support rope/wire to ensure Ceiling Panel is level.
- b. Turn on circuit breaker and test light.
Product Details
Recommended Dimmers
Specifications
Troubleshooting
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem. If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light
source. It is an important factor to consider when selecting a fixture or
bulb, as it affects the way it will illuminate an area. There are two main
types of lighting distribution angles: A symmetric lighting distribution emits
light evenly in all directions, creating a cone-shaped pattern that provides a
pool of light. This type of lighting is ideal for general lighting and
illuminating large areas. Common applications for symmetric lighting include
general area illumination, security lighting, and perimeter lighting.
Symmetric lighting is also used to a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more. It is important to note that
the lighting distribution angle can also be affected by other factors such as
the reflector design of the light source, the type of lens used, and the
distance between the light source and the surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry leading 7 year warranty. ****
It gets even better – scan the QR code for 2 extra years of protection!
30 Day Return Policy
At Sunco, we value our customers and stand by the quality and performance of our products. If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:
- Email:
- Call or Text:
References