DRAGON GT015 Height Adjustable Desk Instruction Manual
- June 1, 2024
- DRAGON
Table of Contents
DRAGON GT015 Height Adjustable Desk
HEIGHT ADJUSTABLE DESK
L SHAPE- LEFT
Tools Included
Assembly Instructions
STEP 1
STEP 2
STEP 3
STEP 4
HEIGHT ADJUSTABLE DESK
(L SHAPE – RIGHT)
Tools Included
Assembly Instructions
STEP 1
STEP 2
STEP 3
STEP 4
OPERATION MANUAL
Monitor
- : UP
- : DOWN
- 1: Height I
- 2: Height Il
- 3: Height Ill
- : Reset
Up and down key operation
- When the “up” key is pressed, the desktop runs upward until the highest point of the desktop is reached.
- When the “down” key is pressed, the desktop runs downward until the lowest point of the desktop is reached.
- When you press the “up” or “down” button for a short time, the desktop will run for a small distance to realize inching.
Position storage / memory operation
- Position storage: three memory points can be stored. The storage method is as follows. When running to a specific point, long press the “1/2/3” key until the digital number flashes, and the current height is successfully stored to the corresponding label.
- Memory position operation: press the “1 / 2 / 3” key for a short time, the nixie tube flashes the memory position height of 25, and the desktop automatically runs to the height of the memory position. Any key can stop the operation during operation
Lock and unlock
- Lock: Press and hold “1” + “2” for 5 seconds at the same time, when the digital tube displays “L”, it means that the system is locked, and the system cannot be lifted or lowered.
Standing and sitting time reminder (countdown mode)
- Countdown time: provide three gears of time, T30 = 30 minutes, T45 = 45 minutes, T60 = 60 minutes.
- Start Countdown: short press “RST” to display T30 / T45 / T60 in sequence, and the countdown starts.
- Exit Countdown:
- Press “RST” for a short time, and the display will display the number.
- When the countdown time is up, the display will flash for 1 minute. Press any key to stop counting and exit.
- If there is no operation, the timer will automatically exit after 3 reminders every 5 minutes.
Restore factory set parameters
- Method: press and hold “1” + “3” for 5 seconds at the same time, and the digital tube displays “C L R”, which means that the parameter recovery is successful
ERROR CODE TABLE
ERROR CODE | EXPLAIN | SOLUTION |
---|---|---|
EOl | Motor not connected | Press the up key orthe down key again. If it still |
exists, please check the connecting wire of the motor
E02| Motor over-current| Press the up or down key again. If the problem still
exists, replace the motor or reduce the load
E03| Motor Hall fault| Press the up or down key again. If the problem still
exists, please check the connection or replace the motor
E04| Abnormal main power supply| If it cannot be eliminated after power
failure, replace the power supply
EDS| Abnormal current of motor| It cannot be eliminated after power failure
and needs to be eturned to the factory
E06| MOS(Components of drive motor) damage| It cannot be eliminated after
power failure and needs to be returned to the factory
E08| Over temperature protection| Wait for the temperature to drop
E09| Motor stall| Press the up or down key again. If the problem still exists,
replace the motor or reduce the load
RST| Abnormal power failure| Reduce the load or check whether the power
connecting wire is loose