Sunco Lighting SH_F LED Shop Light
Specifications
- Voltage: 5 ft. Length
- Wattage: 4500LM
- Wattage Equivalency: N/A
- Beam Angle: 80+
- Color: Indoor
- Housing Material: N/A
- Dimmable: Yes
- Average Lifetime: 50,000 hrs
- Lumens: 4500LM
- Moisture Rating: Damp
- CRI: 80+
- Usage Frequency: 60Hz
- Warranty: 7 Years
Product Usage Instructions
Quickstart Guide
- Attach hanging chains to shop light mounting ends.
- Drill 2 pilot holes into ceiling.
- Zip tie fixture cord to chain.
- Plug in power cord to electrical outlet.
Installation Guide (Suspension Install)
- STEP 1
1. Turn off circuit breaker before installation. Mounting surface must support fixture weight.
2. Insert hanging chains to the shop light mounting ends.
- STEP 2
1. Drill 2 pilot holes into ceiling. Holes should be 46.83″ apart.
2. Dry Wall: Use a 7/32 drill bit. Wall Stud: Use a 9/64 drill bit.
Frequently Asked Questions
Common Troubleshooting
If you are experiencing any issues with your product, refer to the
troubleshooting section in the manual. If problems persist, feel free to
contact our support team for assistance.
support@sunco.com
844-334-9938
What’ s in the B ox?
Shop Light
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off the circuit breaker before installing this fixture.
- Suitable for damp locations at temperatures ranging from 4°F to 113°F. Not for use where directly exposed to water.
- Not intended for use with emergency fixtures.
- This product is not compatible with dimmers.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with 3rd party occupancy sensors.
- This product is not compatible with 3rd party timing devices.
- All electrical connections must be in accordance with local National Electric Code (N.E.C.) standards.
- Please review the installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.
WARNING:
Cancer & Reproductive Harm-
www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
Step 1
Attach hanging chains to shop light mounting ends.
Step 2
Drill 2 pilot holes into ceiling.
Step 3
Zip tie fixture cord to chain.
Step 4
Plug in power cord to electrical outlet.
Installation Guide (Suspension Install)
STEP 1
-
Turn off circuit breaker before installation.
NOTE: Mounting surface must be able to support weight of fixture. -
Insert hanging chains to the shop light mounting ends.”(Remove everything else)
Step 2
- Drill 2 pilot holes into ceiling. Holes should be 46.83” apart.
- Dry Wall: 7/32” drill bit.
- Wall Stud: 9/64” drill bit.
STEP 3
- Secure fixture to ceiling by hanging non-crimped portion of S-hooks onto eye hooks. Adjust chain length as needed.
- Secure fixture power cord to mounting chain using zip tie.
STEP 4
- Insert expansion anchors into pilot holes.
NOTE: Space fixture to suit your lighting plan and power chord length (60”). 4 units maximum.
STEP 5
Plug in power cord to electrical outlet.
STEP 6
- Tighten screw eye hooks into expansion anchors.
- Turn on circuit breaker and test light.
Installation Guide (Direct Mount Install)
STEP 1
- Turn off circuit breaker before installation.
NOTE: Mounting surface must be able to support weight of fixture.
STEP 2
NOTE: Space fixture to suit your lighting plan and power chord length (60”). 4 units maximum.
STEP 3
- Drill 2 pilot holes into ceiling. Holes should be 46.83” apart.
- Dry Wall: 7/32” drill bit.
- Wall Stud: 9/64” drill bit.
STEP 4
- Align fixture to screws.
- When holes are aligned, push fixture up.
Slide to secure.
STEP 5
- Insert expansion anchors into pilot holes.
- Tighten screws into expansion anchors.
- Leave about 0.17” gap between the screw heads & mounting surface.
STEP 6
- Plug in power cord to electrical outlet.
- Turn on circuit breaker and test light.
Product Details
Dimensions
Specifications
Voltage | 120V | Average Lifetime | 50,000 hrs | |
---|---|---|---|---|
Wattage | 40W | Lumens | 4500LM | |
Wattage Equivalency | 150W | Moisture Rating | Damp | |
Beam Angle | 120° | CRI | 80+ | |
Color | Black/White | Usage | Indoor | |
Housing Material | Plastic | Frequency | 60HZ | |
Dimmable | No | Warranty | 7 Years |
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light
source. It is an important factor to consider when selecting a fixture or
bulb, as it affects the way it will illuminate an area. There are two main
types of lighting distribution angles:
Asymmetric lighting distribution emits light evenly in all directions,
creating a cone-shaped pattern that provides a pool of light. This type of
lighting is ideal for general lighting and illuminating large areas. Common
applications for symmetric lighting include general area illumination,
security lighting, and perimeter lighting. Symmetric lighting is also used to
a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be
affected by other factors such as the reflector design of the light source,
the type of lens used,and the distance between the light source and the
surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry-leading 7-year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
30-Day Return Policy
At Sunco, we value our customers and stand by the quality and performance of our products.
If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:
Email: support@sunco.com
Call or Text: 844-334-9938
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>