FLEXTAILGEAR HT-767 SUP Electric Air Pump Instruction Manual

June 4, 2024
FLEXTAILGEAR

FLEXTAILGEAR HT-767 SUP Electric Air Pump

Product Introduction

Thank you for purchasing this product,HT-767 is an intelligent DC electric pump with the preset pressure LCD screen, which can be used for inflatable tent, SUP, etc.Thanks to the intelligent pressure system, for example, if a pressure value is preset, when the pressure reaches the preset pressure value, the pump will automatically stop inflating.

List of Accessories

Please make sure that the following accessories are in the box before using it, if any missing, please contact with the local service agents.

FLEXTAILGEAR HT-767 SUP Electric Air Pump-fig2

Details of Accessories

  1. Inflation inlet
  2. Deflation outlet
  3. DC plug
  4. Pressure value LCD screen
  5. On/off button
  6. Pressure unit toggle button
  7. Pressurizing button
  8. Decompressing button
  9. Hose
  10. Air tap
  11. Flexible conduit adaptor

Safety Instructions

  • Warning: ln order to reduce the risk of injury, please keep children away from it. Always supervise children and incapacitated person contacting or using this air pump.
  • Warning: To reduce the risk of electric shock, do not expose to rain or immersed in water.
  • Warning: This product is not applicable for the person with declining physical strength, sensory ability or mental capacity, the person lack of skill and the mentally retarded person, unless they are under the protection of their guardians, supervised and directed at the same time.
  • Warning: Before moving, maintaining, repairing or adjusting this product,please first pull out the DC plug from the socket.
  • Warning: Please do not bury the wire in the soil, and it shall be place in the safe zone where it won’t be damaged by mower or other equipment.
  • Warning: lf the power wire is damaged,the power wire must be changed by the manufacturer or its service agent or the similar authorized personnel, in case of any risk.
  • Warning: lf you are standing in a place with water or your hands are wet, please don’t plug or pull the DC plug.
  • Warning: Before inflating, please pay attention to check the maximum bearable pressure of the inflatable product, because the air bag may be damaged upon exceeding the maximum bearable pressure.
  • Warning: Before using, please check the cigarette lighter socket to make sure that there is no rust or residue inside.The cigarette lighter socket with poor electric conduction may cause overh neating of the product or power source, which will damage the product.
  • Warning: The purpose of using this product is limited to the description in the instructions.

Inflation Operation

  • Connect the end with flexible conduit adaptor (11) of the hose with the air pump inflation inlet (1), and twist clockwise to tighten it, as Figure 1

  • Install the other end of the hose into the supporting air tap of the air bag (step①in Figure 2), and twist clockwise to tighten it, and then insert the inflation valve of the air bag and twist clockwise to fix it (step②in Figure 2).

  • Plug the DC plug into the 12V DC socket.

  • Press the pressure unit toggle button to select the unit you need.

  • Press the pressurizing button or decompressing button to set the pressure value you need, with the range of the pressure value from
    0 to 20PSl, (1PSI=0.0689BAR)

  • After finishing the above steps, press the power switch button to start to inflate.

  • During the inflating process, you can press the pressurizing button or decompressing button to increase or reduce the pressure value, press the pressure unit toggle button to switch the unit, and press the On/Off button to stop.

  • Press and hold the On/Off button for 3 seconds to directly start the high pressure pump.

  • When the pressure reaches the set value, the air pump will stop working automatically.

  • After completing the inflation, pull out the DC plug from the 12V DC socket.

  • After pulling out the DC plug, please take down the hose from the air pump and air bag and store it.

  • Notice: The factory set pressure value of the air pump is 10PSI (10PSI=0.689BAR), and at the time of the secondary use, the set pressure value for the last time use will be displayed by default.

  • Notice: After powered on, if there is no operation within 2 minutes, the air pump will enter standby mode, and the machine can be initiated by pressing the power switch button.

Deflation operation

  • Remove the hose from the inflation inlet, Connect the end with flexible conduit adaptor (11) of the hose with the air pump deflation outlet (2), and twist clockwise to tighten it, as Figure 3,and the other end shall still be to the airbag.
  • Press the button of the power switch of air pump, and start the deflation until all the gas is discharged, then the power can be turned off to stop the deflation.

Precautions

  • The applied powersource must be the 12V DC power source (as Figure 4).
  • Do not block the inflation inlet (1)and Deflation outlet (2), and ensure that the inflation inlet (1) and Deflation outlet(2) shall remain smooth at all times
  • Observe the local waste treatment provisions, and it is not alowed to throw the air pump away randomly.
  • Don’t use this product when the hose is damaged, and please change the hose immediately.
  • Don’t pull out the hose when inflating, because that the high pressure may hurt the physical body.
  • Don’t pull out the hose when inflating, because that the high pressure may hurt the physical body.
  •  Don’t make the air pump work for more than 20 minutes, because that motor overheating may cause intemal damage; and the air pump shall be fully cooled for 30 minutes after continuously working up to 20 minutes.
  • Please don’t use this air pump if any part is damaged, ande apsle contact with the professional personnel to repair it.
  • In order to prevent risk, the inflation inlet shall not be forward to face or body. Please don’t leave while inflating.
  • Please start the car when using the product, in case of unnecessary damage. Disposal: Do not dispose of this product as unsorted municipal waste. The waste must be collected separately for special disposal.

Fault Handling

Fault Inspection Solutions

The air pump cannot be started normally.

| 1. The power source is

not plugged properly.

2. The fuse in DC plug(3)

is burnt out.

3. Overheatingoroverload

causes motorstop.

| 1. Make sure that the power wire is plugged in the 12VDC socket.

2. Change the fuse.

3. Cool the motor and restart it.

4. If the problem cannot be solved, please contact local service agents or a similar

authorized personnel to change the product.

The machine displays HOT| Check ifthe air pump is working too long and its

inside overheated.

| 30-minute cooling

Sloworabnormal inflationor deflation.

| 1. Check whether the hose is blocked or cracked.

2. The joint between the hose and air pump or airbag is not installed properly.

| 1. Change the hose or make it unblocked, and check whether the hose is cracked.

2. Reinstall the hose.

3. If the problem cannot be solved, please contact local service agents or similar authorized personnel to change the product.

7 series air pump fault code description

Display code Explanation Solutions

U-L/ U-LO/ RRRO

| 1. The LCD screen will prompt when the voltage is less than or equal to 8V,

2. The voltage protection is automatically removed when voltage is restored to

10.5V.

| 1. The power supply voltage is low.

2. The power supply is in sufficient and

the circuit has limited current

3. Power adapter overcurrent protection. Special adapter required (150W unlimited current)

| 1.The LCD screen will|
U-H/ U-HI/ RRRO| prompt when the voltage is above 15V.

2. The voltage protection is automatically removed

whenthe voltage is

|

Over high voltage input

| restored to 14.5V.|
Display code| Explanation| Solutions
---|---|---

T(7) / RRRO

| When the product detects 85 ℃, it is forced to stop, and when it drops to 60 ℃, the fault will be removed

automatically.

|

Need to heat dissipation

E2| When the product detects 100℃, forced shutdown| Need to heat dissipation
E3| When air pressure does not rise, shutdown protection| Check for air leaks

PPPP

| Shutdown protection of air pressure ,the LCD screen displays PPPP and blinks, press any key to exit this

state.

|

Check for air leaks

Maintenance And Storage

  • After using, or if you want to move, maintain or adjust the product, please first pull out the DC plug from the socket.
  • When it is idle, it shall be properly stored after being fully cooled.
  • It shall not be exposed to the rain or immersed in water.
  • Please store it in the dry and ventilated place.

Warranty Policy

Flextailgear has a 1 year warranty on all its pumps from the date of purchase. Flextaigear’s 1 year warranty covers any product proved to be defective because of faulty material or product found broken when the customer received it.This limited warranty does not cover any problem that is caused by: conditions, malfunctions or damage not resulting from defects in material or workmanship. Contact Flextailgear by sending an email to the email address below or by visiting our website. Customer Service Email: service@flextailgear.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FLEXTAILGEAR User Manuals

Related Manuals