Installation notes
For safe installation and commissioning of the dishwasher please read the installation plan, the service documentation, the installation sheet and the operating instructions. This installation plan includes the dimensions of the appliance, the technical data and the requirements to be met on site for the installation of the dishwasher.
Installation requirements
This dishwasher must only be installed and commissioned by the Miele Customer Service Department, a Miele authorised dealer or a suitably qualified specialist. Installation should only be performed in accordance with valid regulations, relevant standards and health and safety codes.
Environmental requirements
Condensate can build up in the area surrounding the dishwasher. Any furniture
and fittings in the room must therefore be suitable for purpose.
Vapour barrier film for built-in appliances
The vapour barrier film supplied protects the worktop from damage caused by steam when the door is opened. Attach the vapour barrier film above the door, underneath the worktop.
Electrical connection
All work on the electrical connection must be carried out by the Miele
Customer Service Department, an authorised Miele dealer or a qualified
electrician.
Plug connection
The dishwasher should be connected to the electricity supply via a socket.
Hard-wired
If the dishwasher is hard-wired to the power supply, a power switch capable
of disconnecting the dishwasher at all poles must be installed on site. This
power switch must have a contact gap of at least 3 mm. The socket and the
power switch must be accessible after the appliance has been installed. An
electrical safety test must be carried out after installation and after any
servicing work. The mains connection cable must be laid protected from the
risk of thermal damage.
Residual current device (RCD)
For increased safety, it is recommended to protect the dishwasher with a
residual current device (RCD) with a trip current of 30 mA.
Equipotential bonding
There is a screw connection point for equipotential bonding at the back of the
dishwasher. Equipotential bonding should be carried out if possible on site.
Water connection
The dishwasher must only be connected to fully vented pipework. A brief
increase in the water pressure can damage components of the dishwasher.
Water inlet
The quality of the incoming water must correspond to the drinking water
specification of the country in which the dishwasher is beingoperated. The
dishwasher must be connected to the water supply in strict accordance with
current local and national water authority regulations. It can be connected to
cold or hot water supplies. Connecting the dishwasher to a hot water supply
will reduce programme running times. For short programme running times, a
water pressure of at least 200 kPa is also required.
If a stopcock is not available, only a qualified installer may connect the dishwasher to the drinking water supply. The stopcock should remain accessible once the dishwasher hasbeen installed so that the water supply can be shut off whenever the appliance is not in use.
Drain
The dishwasher drain hose should be connected to a separate on-site drainage system for the dishwasher only. If a separate connection is not available, we recommend connecting the hose to a dual-chamber siphon. If the hose is to be fitted directly to the drainage system on site, use the hose clip supplied with the dishwasher. The on-site connector for the drain hose can be adapted to different hose diameters. If the connector extends more than 30 mm into the drain hose, it must be shortened. Otherwise, the drain hose can become blocked. Lay the drain hose so that it does not kink and is not being subjected to pressure or tension.
If the on-site drain connection is situated lower than the guide path for the lower basket rollers in the open door, a siphoning effect during a programme can cause the wash cabinet to empty itself of water. In this case, lay the drain hose with a bend in it so that its highest point is at least level with the guide path for the lower basket rollers. For AU, NZ the drain should be connected in accordance with AS/ NZS 3500.2.
External dispensing
An external dispensing module for liquid cleaning agents can be connected to
the back of the dishwasher. The dispensing module is available as an optional
accessory and is supplied with installation instructions.
Appliance dimensions and installation dimensions
Freestanding appliance PFD 100, PFD 101
Built-in appliance/built-under appliance
Front panel dimensions PFD 101 i
Length | [mm] | 500–654 |
---|---|---|
Thickness | [mm] | 16–20 |
Weight | [kg] | 4–11 |
Connections
Connections on the back of the appliance
On-site connections
- Electrical connection
- External dispensing, power supply connection
- Equipotential bonding
- Waste water
- Cold or hot water
- External dispensing, connection for dispensing hose sealed with a blind stopper the dispenser connector is supplied with the dispensing module.
External dispensing
Max. delivery head | [m] | 1.5 |
---|---|---|
Length of dispenser hose, DOS module to suction lance | [m] | 1.8 |
Length of dispenser hose, back of appliance to DOS module | [m] | 2.8 |
Length of power cable, back of appliance to DOS module | [m] | 2.8 |
Place the container on the floor next to the cleaning machine or in an adjacent cabinet. The container must not be placed on top of or above the cleaning machine.
Technical data
Dimensions and weights
Height | [mm] | 845 | 805 | 805 |
---|---|---|---|---|
Height adjustment | [mm] | 35 | 65 | 65 |
Width | [mm] | 600 | 598 | 598 |
Depth | [mm] | 600 | 570 | 570 |
Depth with door open | [mm] | 1195 | 1165 | 1165 |
Max. plinth return | [mm] | – | 115 | 115 |
Weight | [kg] | 60 | 42 | 44 |
Max. floor load | [N] | 1000 | 1000 | 1000 |
Emission levels | ||||
Sound power level | [dB(A) |
re 1 pW]
| 46| 46| 46
Sound pressure level in the workplace| [dB(A)]| 34.1| 34.1| 34.1
Electrical connection
Standard electrical connection PFD 101
|
---|---
Voltage| | AC 230V
Frequency| [Hz]| 50
Fuse rating| [A]| 13
Plug| | +
Power cable length| [m]| 1.7
Power cable cross-section| [mm2]| 3×1.5
Heat output| [kW]| 1.9
Total rated load| [kW]| 2.1
Standard electrical connection PFD 100, Possible voltage variant PFD 101
Voltage *| | AC 230 V
Frequency| [Hz]| 50
Fuse rating| [A]| 32
Plug| | –
Power cable ** length| [m]| 1.7
Power cable cross-section| [mm2]| 3×4
Heat output| [kW]| 6.1
Total rated load| [kW]| 6.3
- Programme running times are longer with this voltage variant.
- Optional accessory.
Water inlet
Max. water temperature | [°C] | 60 |
---|---|---|
Max. water hardness | [mmol/l] | 6.5 |
Max. water hardness | [°dH] | 36 |
Water connection pressure | [kPa] | 100 – 1000 |
On-site threaded union (flat seal) | [inches] | 3/4 |
Connection hose length | [m] | 1.5 |
Connection hose extension * | [m] | 1.5 |
Optional accessory.
Drain
Max. water temperature | [°C] | 82 |
---|---|---|
Drain hose length | [m] | 1.5 |
Max. drain hose length | [m] | 4 |
Max. delivery head | [m] | 1 |
Max. transient flow rate | [l/min] | 10 |
Hose inner diameter | [mm] | 22 |
On-site hose sleeve ( x length) | [mm] | 22 x 30 |
Operating conditions | ||
Ambient temperature | [°C] | +5 – +40 |
Relative humidity:
Up to 31 °C, maximum
| [%]|
80
Linear decreasing to 40 °C| [%]| 50
Max. altitude above sea level up to| [m]| 4000
Storage and transportation conditions
Ambient temperature| [°C]| -20 – +60
Relative humidity| [%]| 10–85
Air pressure| [hPa]| 500–1060
Min. site access dimensions including transport pallet
Height| [mm]| 970
Width| [mm]| 670
Depth| [mm]| 670
United Kingdom
Miele Co. Ltd., Fairacres, Marcham Road
Abingdon, Oxon, OX14 1TW
Professional Sales, Tel: 0845 365 6608
E-mail:professional@miele.co.uk
Internet:www.miele.co.uk/professional
Australia
Miele Australia Pty. Ltd.
ACN 005 635 398, ABN 96 005 635 398
Level 4, 141 Camberwell Road, Hawthorn East, VIC 3123
Tel: 1300 731 411
Internet:www.miele.com.au/professional
E-mail:professional.sales@miele.com.au
China Mainland
Miele Electrical Appliances Co., Ltd.
1-3 Floor, No. 82 Shi Men Yi Road
Jing’ an District, 200040 Shanghai, PRC
Tel: +86 21 6157 3500,
Fax: +86 21 6157 3511
E-mail:info@miele.cn
Internet: www.miele.cn
Hong Kong, China
Miele (Hong Kong) Ltd.
41/F – 4101, Manhattan Place
23 Wang Tai Road, Kowloon Bay, Hong Kong
Tel: (852) 2610 1025, Fax: (852) 3579 1404
Email:customerservices@miele.com.hk
Website:www.miele.hk
India
Miele India Pvt. Ltd.
1st Floor, Copia Corporate Suites,
Commercial Plot 9, Mathura Road, Jasola,
New Delhi – 110025
E-mail:customercare@miele.in
Website: www.miele.in
Ireland
Miele Ireland Ltd.
2024 Bianconi Ave., Citywest Business Campus, Dublin 24
Tel: (01) 461 07 10, Fax: (01) 461 07 97
E-Mail: info@miele.ie,
Internet: www.miele.ie
Manufacturer: Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>