Sunco WR_PR7_DU-WH-4060K 7 Inch LED Prismatic Lens Wraparound Selectable Light User Manual

June 1, 2024
SUNCO

Sunco WR_PR7_DU-WH-4060K 7 Inch LED Prismatic Lens Wraparound Selectable

Light

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-product

Whats in the Box?

Wraparound

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-fig-1

Components

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-fig-2

Before You Start

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

  • Turn off power before changing fixture.
  • Suitable for use in damp environments at temperatures ranging from -4°F to 104°F. Not for use where directly exposed to water.
  • Not intended for use with emergency fixtures.
  • Not compatible with photo-electric sensors.
  • Not compatible with motion sensors.
  • Not compatible with third party sensors.
  • Not compatible with dimmers. For more dimming information, please visit www.sunco.com.
  • Not compatible with timing devices.
  • All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards.
  • Please review installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
    WARNING: Cancer & Reproductive Harm- www.P65Warnings.ca.gov

  2. This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

Quickstart Guide

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-fig-3

Installation Guide (Junction Box Installation)

STEP 1

  • Turn off circuit breaker before installation.
  • For fixture replacement, sketch or label wires for reference.

STEP 2

  • Remove the diffuser from the lamp base.
  • Select desired color temperature and brightness.

STEP 3

  • Screw (AA) into the junction box, leaving 1/4” exposed for the lamp.
  • In the junction box, connect wires: Live (black) to Live; Neutral (white) to Neutral; Ground (yellow/green) to Ground. Secure with wire nuts and tuck into the box.

STEP 4

  • Align Lamp Base holes with junction box screws.
  • Rotate Lamp Base clockwise to secure it, and tighten screws for fixture stability.

STEP 5

  • Punch an end cap hole, remove cables from the lamp base, and connect wires: Live (black) to Live, Neutral (white) to Neutral, Ground (yellow/green) to Ground.
  • The wiring between the fixtures is clamped with wire connectors to ensure that the clamping is not loose, and then put on the heat shrink tube to tighten.
  • Size of conduit ≤1 inch ( 1/2” 3/4” 1” )

STEP 6

  • Reattach the diffuser (cover): Align one end and gently press down. Push the diffuser to the corner of the lamp base. Secure the diffuser with the aluminium base.
  • Restore power by turning on the circuit breaker and test the light.

Installation Guide (Keyhole Installation)

STEP 1

  • Turn off circuit breaker before installation.
  • For fixture replacement, sketch or label wires for reference.
  • The mounting surface must support the fixture’s weight. Detach the diffuser from the lamp base.

STEP 2

  • Choose your preferred color temperature and brightness.
  • Align the Lamp Base with the mounting location using the knockout holes. Mark the 4 keyhole slots at each end of the housing.

STEP 3

DRYWALL MOUNTING (No Stud):
Drill 4 small pilot holes with a 7/32” bit (not included). Insert wall anchors with a hammer. Partially tighten 4 wood screws, leaving a 3/8” gap between the screw head and the mounting surface.

STEP 4

WALL STOP MOUNTING OPTION
Drill 4x small pilot holes with a 9/64” drill bit (not included). Install 4x wood screws into the mounting surface, but not fully. Leave about a 3/8” gap between the screw head and mount surface.

STEP 5

  • Take out the cables from the lamp base. Remove shrink wrap, and connect wires: Live (black) to Live, Neutral (white) to Neutral, Ground (yellow/green).
  • Insert screws into keyhole slots, slide lamp base (a) to align screw heads, and secure fixture to the mounting surface. Use the provided washer for added vibration protection.

STEP 6

  • Reattach the diffuser, align and secure it with the metal base. Restore power and test the light.
  • Turn on the circuit breaker and the test light.

Recommended Dimmers

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-fig-12


Specifications


Voltage

| ** 120V-277V|  | Average Lifetime| ** 50000 hrs
---|---|---|---|---
Wattage| 12.5W/25W/50W|  | Lumens| 1625/2600/6500LM
Power Factor| 0.7|  | Temperature| -4°F to 104°F
Amps| 0.495Am|  | CRI| 80+
CCT| 4000K/5000K/6000K|  | Efficacy| 130lm/w
Housing Material| PC+Steel|  | Usage| Indoor
Dimmable| Non-dimmable|  | Warranty| 7 Years

Common Troubleshooting

Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy- to-follow solutions for any problem.  If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.Sunco-WR-PR7-DU-WH-4060K-7-Inch-
LED-Prismatic-Lens-Wraparound-Selectable-Light-fig-15

Light Distribution Angle

Sunco-WR-PR7-DU-WH-4060K-7-Inch-LED-Prismatic-Lens-Wraparound-Selectable-
Light-fig-13

Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles: A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.

An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums, and much more. It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.

Customer Support

Warranty Policy
This product is covered by our industry-leading 7-year warranty. It gets even better – scan the QR code for 2 extra years of protection!

30 Day Return Policy

  • At Sunco, we value our customers and stand by the quality and performance of our products.
  • If you are not completely satisfied with your purchase, we accept returns within 30 days of your purchase date.

Customer Service
Our Los Angeles team of lighting experts is here to assist you with all your needs! Contact us at:

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals