QLT DIMCUBE 24 and Dimmable Interfaces
DIMCUBE 24 and DIMCUBE48 Interfaces
- Rated values at 24V refer to item DICUBE24N
- Rated values at 48V refer to item DICUBE48N
Technical Data
-
Rated supply voltage
- 24 or 48V DC
-
Max. main current
- 11A@24V 7A@48V
-
Efficiency
-
96%
-
-
Standby power
- <0,5W
-
Digital input
- Push Button input ON/OFF Dimmer
-
Analog Input
- 0_10
-
Push line Max cable length
- 20 m con 0.5 – 2.5mmq
-
Input selector
- DIP Switch
-
Operating frequencies
- 250Hz PWM
-
Max output current
- 11A@24V 7A@48V
-
Max output power
- 264W@24V 336W@48V
-
Protections
- Open load Short circuit, overload
-
Connections
- Screw connectors 0.5..2.5mmq
-
Operating temperature
- -10°C … +45°C
-
TC point
- 60° tested on the label surface
-
Storage temperature
- -15°C … +50°C
-
Dimensions LxPxA
- 41x47x20 mm
-
Weight
- 30g
-
Protection degree
- IP 20
Synchro procedure
In the case of systems with more devices controlled by push-button,
synchronization is achieved by holding the control for a long time until
maximum light is reached on all devices.
State memory
Push button operation The dimmer memory is kept with a continuous power supply
only
Safety note
Installation of this device may only be carried out by specialist staff.
Switch off the mains supply before device connection Keep this document in a
safe place Respect the safety and accident prevention regulations Dispose of
it according to instructions.
Standard and Directives
2014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU + 2015/863/EU (RoHs)EN
61347-2-13:2014 + A1:2017; EN 61347-1:2015 EN 55015:2019 + A11:2020 EN IEC
63000:2018
Areas of application
The device may only:
- be used for the applications specified.
- be used for safe installation in a dry and clean environment.
- be installed in such a way that access is only possible using a tool.
Dimensions (mm)
Frequently Asked Questions (FAQ)
Q: What should I do if the device does not power on?
A: Check the power supply connection and voltage compatibility. Ensure the
current drawn is within the specified limits.
Q: How can I determine the model of my device?
A: The model can be found on the device label or in the user manual. Look
for DICUBE24N for 24V and DICUBE48N for 48V.
Q: Is it safe to operate the device at different voltage levels?
A: No, always use the specified voltage (24V or 48V DC) to prevent damage
to the device.
- Qualitron s.r.l. Via Dolomiti 15 20027 Rescaldina ( Milano ) Italy WWW.QLT.IT qlt@qlt.it
- Specifications subject to change without notice
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>