QLT DIMCUBE 24 and Dimmable Interfaces Installation Guide

June 1, 2024
QLT

QLT DIMCUBE 24 and Dimmable Interfaces

QLT-DIMCUBE-24-and-Dimmable-Interfaces-PRODUCT

DIMCUBE 24 and DIMCUBE48 Interfaces

  • Rated values at 24V refer to item DICUBE24N
  • Rated values at 48V refer to item DICUBE48N

Technical Data

  • Rated supply voltage

    • 24 or 48V DC
  • Max. main current

    • 11A@24V 7A@48V
  • Efficiency

    • 96%

  • Standby power

    • <0,5W
  • Digital input

    • Push Button input ON/OFF Dimmer
  • Analog Input

    • 0_10
  • Push line Max cable length

    • 20 m con 0.5 – 2.5mmq
  • Input selector

    • DIP Switch
  • Operating frequencies

    • 250Hz PWM
  • Max output current

    • 11A@24V 7A@48V
  • Max output power

    • 264W@24V 336W@48V
  • Protections

    • Open load Short circuit, overload
  • Connections

    • Screw connectors 0.5..2.5mmq
  • Operating temperature

    • -10°C … +45°C
  • TC point

    • 60° tested on the label surface
  • Storage temperature

    • -15°C … +50°C
  • Dimensions LxPxA

    • 41x47x20 mm
  • Weight

    • 30g
  • Protection degree

    • IP 20

Synchro procedure
In the case of systems with more devices controlled by push-button, synchronization is achieved by holding the control for a long time until maximum light is reached on all devices.

State memory
Push button operation The dimmer memory is kept with a continuous power supply only

Safety note
Installation of this device may only be carried out by specialist staff. Switch off the mains supply before device connection Keep this document in a safe place Respect the safety and accident prevention regulations Dispose of it according to instructions.

Standard and Directives
2014/35/EU (LVD); 2014/30/EU (EMC); RoHs 2011/65/EU + 2015/863/EU (RoHs)EN 61347-2-13:2014 + A1:2017; EN 61347-1:2015 EN 55015:2019 + A11:2020 EN IEC 63000:2018

Areas of application
The device may only:

  • be used for the applications specified.
  • be used for safe installation in a dry and clean environment.
  • be installed in such a way that access is only possible using a tool.

Dimensions (mm)

QLT-DIMCUBE-24-and-Dimmable-Interfaces-FIG-2 QLT-DIMCUBE-24-and-Dimmable-Interfaces-FIG-3

Frequently Asked Questions (FAQ)

Q: What should I do if the device does not power on?
A: Check the power supply connection and voltage compatibility. Ensure the current drawn is within the specified limits.

Q: How can I determine the model of my device?
A: The model can be found on the device label or in the user manual. Look for DICUBE24N for 24V and DICUBE48N for 48V.

Q: Is it safe to operate the device at different voltage levels?
A: No, always use the specified voltage (24V or 48V DC) to prevent damage to the device.