Panasonic U-19PN1H5 Non Inverter Outdoor Unit Instruction Manual

June 1, 2024
Panasonic

Panasonic-logo

Panasonic U-19PN1H5 Non Inverter Outdoor Unit

Product Information

Specifications

  • Model: U-19PN1H5 / U-25PN1H5
  • Phase: 1-phase
  • Refrigerant Tubing (Liquid Tube): Flared connection (6.35)
  • Refrigerant Tubing (Gas Tube): Flared connection (12.70)
  • Mounting Hole: 4-R6.5, anchor bolt: M10
  • Dimensions: 824mm x 540mm x 160mm

Product Usage Instructions

  • Installation
    To install the outdoor unit, ensure a space of at least 100mm on all sides for proper ventilation and maintenance.

  • Mounting
    Use the provided mounting hole (4-R6.5) and anchor bolt (M10) to securely mount the unit in place.

  • Refrigerant Tubing Connection
    Connect the liquid tube with a flared connection of 6.35 size and the gas tube with a flared connection of 12.70 size.

  • Valve Configuration
    The unit features a 2-way valve at the liquid side and a 3-way valve at the gas side for high and low-pressure regulation.

  • Maintenance
    Regularly check and clean the air intake and discharge areas to ensure optimal performance.

FAQ

  • Q: How do I connect the refrigerant tubing?
    A: Use the specified flared connections for the liquid and gas tubes as mentioned in the manual.

  • Q: What is the recommended space for installation?
    A: Allow a minimum of 100mm clearance around the unit for proper installation and maintenance.

Dimensions

Dimensions (U-19PN1H5 /U-25PN1H5) 1-phase

  1. Mounting hole (4-R6.5), anchor bolt: M10
  2. Refrigerant tubing (liquid tube), flared connection ( 6.35)
  3. Refrigerant tubing (gas tube), flared connection ( 12.70 )

Panasonic-U-19PN1H5-Non-Inverter-Outdoor-Unit-fig-
\(1\)

Dimensions (U-30PN1H5) 1-phase (U-30PN1H8/U-36PN1H8) 3-phase

  1. Mounting hole (4-R6.5), anchor bolt: M10
  2. Refrigerant tubing (liquid tube), flared connection ( 9.52)
  3. Refrigerant tubing (gas tube), flared connection ( 15.88 )

Panasonic-U-19PN1H5-Non-Inverter-Outdoor-Unit-fig-
\(2\)

Dimensions (U-42PN1H8/U-50PN1H8) 3-phase

When using a drain pipe, install the drain socket (field supply) onto the drain port. Seal the other drain port with the rubber cap.

  1. Mounting hole (4-R6.5), anchor bolt: M10
  2. Refrigerant tubing (liquid tube), flared connection (Ø9.52)
  3. Refrigerant tubing (gas tube), flared connection (Ø15.88)
  4. Refrigerant tubing port
  5. Electrical wiring port (Ø13)
  6. Electrical wiring port (Ø22)
  7. Electrical wiring port (Ø27)
  8. Electrical wiring port (Ø35)

Panasonic-U-19PN1H5-Non-Inverter-Outdoor-Unit-fig-
\(5\)