lnstallation Precautions

  1. When you open the product packing, please check the product and accessories at first. If there is any discrepancy, please contact the company or our distributor immediately.

  2. The hot and cold water supply pipe of the faucet must be properly connected.
    When facing the front of the faucet, the hot water supply is on the left and cold water supply is on the right. Incorrect connection will cause permanent damage to the cartridge.

  3. lf the accessories to be changed without affecting the use, we will not make a prior notice.

  4. The impurities in the water supply pipe must be cleared before installation to avoid blockage.

  5. The water pressure of the faucet is 20 PSI -100 PSl(including cold water and hot water pressure) Applicable water temperature range: 40°F-170°F.

Preparation before installation

  1. Please read the installation manual carefully before installation.
  2. Installation work must be performed by a professional installer.
  3. lnstallation tool.

Tools you may need.

Alt-Aqua-93108-Bathroom-Shower-System- \(2\)

Product reparation

If the cartridge is worn out which cause leakage, please turn off the water source. Remove the handle, panel, and decorative cover in sequence, remove the gland with a wrench, then take out the cartridge and copper sleeve.
Repair or replace the new cartridge,then install it again in sequence.

Clearance and Maintenance

In order to keep the faucet appearance smooth and good performance, please follow the below steps to clean and maintain the faucet.

  1. Clean with water and dry with a soft cotton cloth.
  2. Use a mild liquid and a colorless glass cleaner to remove surface dirt and scale, also you can use the cleaner without grinding function.
  3. Do not use detergents, polishing tools, abrasive cloth, paper towels or scrapers to clean the faucet.
  4. Do not use acid cleaners, insoluble granular detergents, soaps, etc to clean the faucet.

Model:93108
Installation Instruction 1/5 Alt-Aqua-93108-Bathroom-Shower-System-
\(3\)

No

1

2

| Description

Screws Rough-in Valve

| QTY

4

1

---|---|---
3

4

| Decorative Cover

Water outlet rod

| 1

2

5

6

| Support rod

Shower Head

| 1

1

7| Spacer| 4
8

9

10

| Expansion Screw Sleeve

Plug Rough-in Valve

| 8

3

1

11

12

| Screws

Panel

| 8

1

13

14

| Diverter Knob Hexagonal Screws| 1

4

15| Decorative Hats| 2
16

17

| On/off Handle

Hexagon Wrench

| 1

1

18

19

| Connector Fixing bracket| 1

2

20

21

22

| Hexagonal Screws

Sliding Bar

Handle Shower

| 2

1

1

23| Shower Hose| 1

Installation Instruction

Alt-Aqua-93108-Bathroom-Shower-System- \(4\)

Installation Instruction 2/5

Installation of valve

  1. The size of the embedded box that needs to be drilled is 4.72″ *6.69″Alt-Aqua-93108-Bathroom-Shower-System- \(5\)
  2. The depth of the embedded box is 2.56″ – 3.15″ It’s better to drill the depth of 2.75″for blank wall Max.80mm Installation of Rough-in Valve
    • Stick the valve to the wall, mark the position of four wall mounting holes with a pencil, then install the valve in the hole.
    • Wrap the sealing tape around the thread of the water inlet pipe and screw it on. Alt-Aqua-93108-Bathroom-Shower-System- \(7\)

Installation Instruction 3/5

Water Testing And Sealing Testing

  1. After the pipeline connection is completed, tighten the plug, open the switch to make the pipeline is under pressure. Check the pressure resistance and sealing performance of the valve and pipeline to ensure that there is no leakage in the pipeline.
  2. Close the switch, unscrew the plug to flush the impurities and sludge to avoid blockage and affect the water flow function;Make sure there is no problem with the pipeline. It can be connected to the head shower, hand-hold.Alt-Aqua-93108-Bathroom-Shower-System- \(8\)
  3. Cut away the part of the embedded box sticking out so that it is parallel with the wall.
  4. Remove the screws and take out the protective cover.
  5. The panel and the handle are connected to the control valve .

Installation of the Head Shower

  1. 0n the basis of plastic box, drill a hole on the wall according to the following photo, and pay attention to the connection between rain inlet and waterfall inlet. Alt-Aqua-93108-Bathroom-Shower-System- \(12\)
  2. The fixed plastic box shall be level with reference to the level gauge, and the water pipe shall be connected for 24 hours to ensure sealing. Do not take off the protective cover when sealing the wall with cement to avoid cement splashing on the threads of copper parts. Installation Instruction 4/5
  3. The tile surface is level with the plastic box surface, and the transparent protective cover protrudes from the tile surface.
  4. lnstall the main body of the shower head, take off the protective cover, twist off the baffle, and then lock the water inlet part. The middle rod is a support rod (no water would pass). Drain the garbage and dirt in the pipeline through water.
  5. lnstall the decorative panel. Reminder: Before sealing the plastic box inside the wall, install the shower according to steps 4-5-6 to test the levelness, verticality,depth and sealing, so as to avoid the trouble of breaking the wall after finding problems after sealing the wall.
  6. Alt-Aqua-93108-Bathroom-Shower-System- \(14\)lnsert the main body of the shower head according to the corresponding water inlet part.Lock the screws with Allen key, and the installation is completed. Final finished product
    Reminder: When installing this product,it is not necessary to loosen the hexagon screws on the back cover of the main body of the shower.Do not disassemble it. Alt-Aqua-93108-Bathroom-Shower-System-
\(16\)

Installation Instruction 5/5

Sliding bar and shower seat installation

  1. Mark 4 holes on the mounting wall, drill with an electric drill, and drive in 4 expansion screw sets with a hammer.
  2. Place the fixed piece, tighten the 4 wall screws, then press the sliding bar horizontally against the wall, and tighten it with the small hexagon socket screws of the fixed seat.Alt-Aqua-93108-Bathroom-Shower-System- \(17\)
  3. Screw on the water outlet connector into the reserved pipe section
  4. Connect the handheld shower and hose to the water outlet Alt-Aqua-93108-Bathroom-Shower-System- \(18\)