SyberSense XPD-03 Door Window Sensor Instruction Manual
- June 1, 2024
- SyberSense
Table of Contents
Door/Window Sensor Installation Sheet
Part number:
Door/Window Sensor, White (XPD-03)
Description
The XPD-03 Door/Window Sensor is a magnetic sensor device designed to fit seamlessly alongside a door frame or windowsill. When the door or window are opened, the magnetic contact is disrupted, and the sensor transmits an alarm notification to the control panel.
Important safety instructions
Before you install this sensor, be sure to:
- Read, keep, and follow all instructions.
- Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
- Do not expose the device to water.
- When there is a low battery, replace with a compatible lithium ion battery.
Installation
The door/window sensor can be installed using the provided adhesive or screws.
Mounting orientation
The sensor and magnet should be placed near the top of the door with the
sensor attached to the unmoving part of the closure. For example, attach the
main body of the sensor to the door frame, not the door. We recommend that the
sensor is placed in the top corner of the opening side of the door, see Figure
Figure 1: Sensor orientation
The sensors and magnet each have a slightly engraved line. This line denotes where the sensors align to function properly. If the sensor and magnet, when together/closed, do not line up correctly, the sensor will not report correctly. See Figure 2.
The sensors and magnet each have a slightly engraved line. This line denotes where the sensors align to function properly. If the sensor and magnet, when together/closed, do not line up correctly, the sensor will not report correctly. See Figure 2.
Figure 2: Sensor alignment
To install the door/window sensor:
3. Select the desired position for the sensor and magnet.
Notes
- The sensor and magnet must be within .25 inch of each other on final installation. See Table 1 for different gap ranges for metallic and non-metallic mounting surfaces.
- Verify that the sensor and magnet are aligned correctly. See Figure 2
4. Remove the sensor’s battery pull tab.
5. Adhere the sensor to the wall using the provided screws and/or
adhesive.
Note: We recommend using the provided screws for installation. This
method is more secure than using adhesive.
Screws
a. Locate the bottom of the sensor (the slotted short end).
b. Turn the sensor over, and then gently slide a fingernail/fingertip into the
slot pushing the sensor’s back plate up and away from the sensor body. (You
can see the FCC label on the inside of back plate.)c. Remove the adhesive
film cover. (Optional)
d. Place the back plate against the door frame/windowsill, making sure that
the orientation is correct for the desired position.
Note: Once the adhesive is secure, the sensor cannot be moved.
e. (Optional) Mark the screw hole locations, then using a power drill, drill
holes and install the 2 provided wall anchors.
f. Insert the first screw into the non-breakaway screw hole, and then use a
screwdriver to partially secure the screw in the wall.
Do not fully insert the screw until the second screw has secured the sensor
position.
g. Insert a second screw into the breakaway screw hole, and then partially
secure in the wall.
h. Observe the sensor position. When satisfied with position, user a
screwdriver to fully secure each screw in the wall.
i. Press the front of the sensor against the base, until there is an audible
snap.
Adhesive
a. Select the desired position for the sensor.
b. Peel one side of the adhesive tape, and then press the tape firmly against
the sensor.
Note: Once the adhesive is secure, the sensor cannot be moved.
c. Peel the other side of the adhesive, and then press the sensor against the
wall.
6. Line the magnet up with the sensor, verifying that they align properly,
and then adhere the sensor to the wall using the provided screws or adhesive.
Screws
a. Locate the bottom of the magnet (the slotted short end). b. Turn the magnet over, and then gently slide a fingernail/fingertip into the slot pushing the magnet’s back plate up and away from the magnet body.
c. Remove the adhesive’s film cover (Optional), and then place the back plate
against the door/window, making sure that the orientation and alignment are
correct for the desired position.
Note: Once the adhesive is secure, the magnet cannot be moved.
d. (Optional) Mark the screw hole locations, then using a power drill, drill
holes and install the 2 provided wall anchors.
e. Insert the first screw into a screw hole, and then use a screwdriver to
partially secure the screw in the wall.
Do not fully insert the screw until the second screw has secured the magnet
position.
f. Insert a second screw into the remaining hole, and then partially secure in
the wall.
g. Observe the magnet position. When satisfied with position, user a
screwdriver to fully secure each screw in the wall.
h. Press the front of the magnet against the base, until there is an audible
snap.
Adhesive
a. Select the desired position for the magnet.
b. Peel one side of the adhesive tape, and then press the tape firmly against
the magnet.
Note: Once the adhesive is secure, the magnet cannot be moved.
c. Peel the other side of the adhesive, and then press the magnet against the
wall.
7. Add the sensor to the panel.
8. Once added, test the sensor. Verify that when the door/window is
opened that the panel notes that the sensors is faulted.
Note: Testing all sensors to the alarm monitoring station is strongly
advised.
Table 1: Sensor and magnet gap range
Non-metallic surface | Supports | Metallic Surface |
---|---|---|
Open | Close | Direction |
31 mm | 29 mm | X |
34 mm | 31 mm | Y |
35 mm | 31 mm | Z |
Battery replacement
The XPD-03 Door/Window Sensor requires a CR2032 battery. Once the battery is low, the panel displays a low battery icon next to the sensor in the devices list. The battery must be replaced within 7 days of the first low battery notification. If the battery is not replaced within 7 days, the sensor may not function properly.
WARNING: If an incompatible replacement battery is used, or the battery
is installed incorrectly explosion or damages may occur.
To replace the battery:
10. Locate the bottom of the sensor (the slotted short end).
11. Gently slide a fingernail/fingertip into the slot and pull the sensor
cover out and away from the sensor’s base.
12. The sensor containing the battery and circuit board is no longer
attached to the door/window.
Locate the tab holding the circuit board in the sensor.
13. Press and hold the tab away from the circuit board, and then turn the
sensor over.
The circuit board comes free from the sensor shell.
14. Use a fingernail/fingertip to push the battery out of the casing,
noting the polarity of the battery.
15. Slide a new CR2032 battery into the battery casing, making sure that
the polarity is correct.
16. Press the circuit board back into the sensor casing until secure.
There will be an audible snap.
17. Press the sensor back onto the base.
18. Test the sensor.
Specifications
Wireless signal range | 820.21 ft. (250 m) |
---|---|
Transmitter frequency | 433MHz TX |
Encrypted | Yes |
Transmitted indications | Tamper Low battery |
Battery type | CR2032 (220mAh) |
Battery life | 5 years |
Screw size | M3 x 16mm |
Adhesive | 3M 4930 |
Sensor dimensions (w x H x D) | 1.69 x 2.52 x .51 in. (43 x 64.05 x 13 mm) |
Operating environment
Temperature
Relative humidity| 32 to 122.6°F (0 to 50°C)
85% max
Water resistant| No
Regulatory information
Manufacturer | Syber Sense |
---|---|
North American standards | ETL listed to: UL 634, ULC ORD634 |
FCC ID: 2AVDC-XPD-201
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be colocated or operating in conjunction with any other antenna or transmitter.
Environmental class| UL: Indoor dry
IEC: 3K5
---|---
EU compliance| ****
EN 54| EN 54-00:0000
European Union directives| 1999/5/EC (R&TTE directive): Hereby, Syber Sense
declares that this device is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
2004/108/EC (EMC directive): Hereby, Syber Sense declares that this device is
in compliance with the essential requirements and other relevant provisions of
Directive 2004/108/EC.
2002/96/EC (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info.
Contact information
Homeowners should contact their installation dealer for assistance.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>