SyberSense XPT01E1433 Wireless Sensor Translator User Guide

June 12, 2024
SyberSense

SyberSense XPT01E1433 Wireless Sensor Translator

SyberSense XPT01E1433 Wireless Sensor Translator-
product

Introduction

The Wireless Translator by Sybersense IoT allows you to reuse existing Honeywell & 2GIG wired or wireless sensors with the Sybersense Panel. It is compatible with XP02/XP06 Security Panels and can convert the 345MHz signal to a 433MHz signal for wireless sensors. The Translator supports 2 wired sensors and has a unique Wireless ID for each zone. It also supports all sensor alarm, supervisory, and trouble signals, as well as Sybersense DHM system and Cover Tamper. The Translator has dual antennas to increase transmit and receive range and operates on a backup battery.

Included Material

  • Translator*1
  • Wall screw*2
  • Expansive rubber sleeve*2

Product Appearance

SyberSense XPT01E1433 Wireless Sensor Translator-
fig-1

Product Features

  • Listens to 2G1G and Honeywell 345MHz radio frequency protocol wireless sensors.
  • Converts to 433MHz radio frequency protocol via the Translator (does not support repeater).
  • Compatible with XP02/XP06 Security Panels.
  • Unique Wireless ID for each Zone.
  • Supports 2 wired sensors.
  • Supports all sensor alarm, supervisory, and trouble signals.
  • Supports Sybersense DHM system.
  • Supports Cover Tamper.
  • Dual Antennas to increase Transmit and Receive range.
  • Backup Battery Operation.

Product Specification

  • Wireless Signal Range: RX 150 Meters, TX 200 Meters (To be Verified, Open area)
  • Transmitter Frequency: Rx 345MHz, Tx 433MHz
  • Modulation: OOK
  • Encrypted: 345Mhz unencrypted signal to 433MHz encrypted signal
  • 2-way support: Yes
  • Frequency Hoping: No
  • Supervisions: Yes
  • Heartbeat Interval: 60 minutes
  • Tamper: Yes
  • Wired Support: Yes
  • Battery: Built-in 2000mAh 3.7V Li battery
  • Battery Life Adaptor: 24 hours minimum for Non-Powered Zones, 4 hours minimum for Powered Zones
  • DC Jack: 12VDC 1A, 100-240VAC 50/60Hz, UL certificated
  • Current Draw: Output 12VDC Max. 80mA for wired sensors (TBC)
  • Water Resistance: No
  • Operating Temperature: 0 ~ 49°C
  • Relative Humidity (Storage): 80% Max. non-condensing
  • Sensor Dimensions: 116mm 115mm 26mm
  • Certification: FCC, IC

*Note:

  1. The XPT01 is facing the panel LCD.
  2. The panel is installed at the height of 1.5 meters. The XPT01 is placed at the height of 1.2 meters.
  3. R X Wireless Signal Range: Related to sensor RF Performance 3) Open Area, the location of the sensor can have a significant effect on range.

In open/unobstructed situation, the transmitter range may be greater. In adverse wireless condition, you may encounter a decrease in range.

Product Usage Instructions – Pairing with the Security Panel

  1. Enter Settings in the Panel.
  2. Select Devices and click + at the top right corner.
  3. Select the Translator device to add.
  4. Open the case and trigger the Tamper.
  5. Select a location for the sensor.
  6. Review the installation guide and confirm Done. The new Translator is added.

LED Indicator

LED Power Mode Meaning
LED Power Green On/Flash/Off
Configure Blue On/Off
Translator Mode
Flash Ready to add a sensor to panel via the translator.
Adding Mode Green Flash/Off
Flash Received a signal for adding a sensor.
Duplicated Mode Red Flash/Off
Flash The Panel tells the Translator that it is sending an already

added sensor signal to Panel. And Panel shows the duplicated SN on
the screen (tbd).

FCC Warning

Labeling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Information to user.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Information to the user.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

RF Exposure warning.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.

IC Warning:
RSS-Gen 8.4 User manual notice

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).

Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

RF Exposure warning.
This equipment complies with RSS-102 radiation exposure limits set forth for an uncontrolled environment.