FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type Instruction Manual

June 1, 2024
FUJITSU

OPERATING MANUALFUJITSU ASYG14KETA Air Conditioner Wall Mounted
Type Manual Fujitsu ASYG14KETA

ASYG14KETA Air Conditioner Wall Mounted Type

MODEL:
*please write down the model name.

(Refer to the rating label.)
AIR CONDITIONER (Wall Mounted type)

Before using this product, read these instructions thoroughly and keep this manual for future refere

SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section carefully before you use this product, and be sure to comply with the following safety precautions.

Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows
WARNING

This mark warns of death or serious injury.
CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING
This symbol shows that this product uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
CAUTION
This symbol shows that the operating manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
CAUTION
This symbol shows that information is available such as the operating manual or installation manual
WARNING

  • The appliance shall be installed, operated and stored in a room with a floor area larger than X m².
    Amount of refrigerant chargeM (kg| Minimum room areaX (m2)
    ---|---
    M ≤ 1.22| –
    1.22 < M ≤ 1.23| 1.45
    1.23 < M ≤ 1.50| 2.15
    1.50 < M ≤ 1.75| 2.92
    1.75 < M ≤ 2.0| 3.82
    2.0 < M ≤ 2.5| 5.96
    2.5 < M ≤ 3.0| 8.59
    3.0 < M ≤ 3.5| 11.68
    3.5 < M ≤ 4.0| 15.26

  • This product contains no user-serviceable parts.

  • Always consult authorized service personnel for repairing, installation, and relocation of this product. Improper installation or handling will cause leakage, electric shock, or fire.

  • In the event of a malfunction such as burning smell, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult authorized service personnel.

  • Take care not to damage the power supply cable. If it is damaged, it should be replaced only by authorized service personnel in order to avoid a hazard.

  • In the event of refrigerant leakage, be sure to keep away from fire or any flammables, and consult authorized service personnel.

  • In the event of a thunder storm or any prior sign of a lightning strike, turn off the air conditioner via the remote controller, and refrain from touching the .product or the power source to prevent any electrical hazards.

  • This product shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).

  • This product shall be stored in a well-ventilated area.

  • Be aware that refrigerants may not contain an odour.

  • This product shall be stored so as to prevent mechanical damage from occurring.

  • Disposing of the product shall be done properly, in compliance with national or regional regulations.

  • During transportation or relocation of the indoor unit, pipes shall be covered with the wall hook bracket for protection.
    Do not move this product by holding the indoor unit pipes.

(The stress applied to the pipe joints may cause the flammable gas to leak during operation)

WARNING

  • This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of this product by a person responsible for their safety. Children should be supervised to ensure that they do not play with this product.

  • Dispose of the packing materials safely. Tear and dispose of the plastic packing bags so that children cannot play with them. There is danger of suffocation if children play with the original plastic bags.

  • Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen.

  • Do not start or stop the operation of this product by inserting or pulling out the power plug, or by turning on or off the circuit breaker.

  • Do not use flammable gases near this product.

  • Do not expose your self directly to the cooling airflow for many hours.

  • Do not insert your fingers or any other objects into outlet port or inlet port.

  • Do not operate with wet hands.

  • Do not use means to accelerate the defrosting process or to clean this product, other than those recommended by the manufacturer.

  • Do not pierce or burn.

CAUTION

  • Provide occasional ventilation during use.
  • Always operate this product with air filters installed.
  • Ensure that any electronic equipment is at least 1 m (40 in) away from this product.
  • Disconnect all the power supply when not using this product for extended periods.
  • After a long period of use, ensure to get the mounting of the indoor unit checked to prevent this product from falling down.
  • The airflow direction and the room temperature should be carefully considered when you use this product in a room with infants, children, elderly or sick persons.
  • Keep the surroundings of the outdoor unit clean and tidy, and do not place items around it. Any objects blocking or entering from the outlet ports may cause product malfunction.
  • Do not direct the airflow at fireplaces or heating apparatus.
  • Do not block or cover the intake grille and the outlet port.
  • Do not apply any heavy pressure to radiator fins.
  • Do not climb on, place objects on, or hang objects from this product.
  • Do not place any other electrical products or household belongings under this product. Dripping condensation from this product might get them wet, and may cause damage or malfunction of your property.
  • Do not expose this product directly to water.
  • Do not use this product for preservation of food, plants, animals, precision equipment, art work, or other objects. This may cause quality deterioration of those items.
  • Do not expose animals or plants to the direct airflow.
  • Do not drink the drainage from the air conditioner.
  • Do not pull the power supply cable.

CAUTION

  • Do not touch the aluminum fins of heat exchanger built-in this product to avoid personal injury when you maintain the unit.
  • Do not stand on unstable steps when operating or cleaning this product. It may overturn and can cause injury.

This product contains fluorinated greenhouse gases

PREPARATION

WARNING

  • Take care to prevent infants and young children from accidentally swallowing the batteries.

CAUTION

  • If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and consult your physician.

  • Exhausted batteries must be removed immediately, and be disposed according to the local laws and regulations of your region.

  • Do not attempt to recharge dry batteries.

  • Do not use dry batteries that has been recharged.

Indoor unit accessories

Please check that the following accessories are included.FUJITSU ASYG14KETA
Air Conditioner Wall Mounted Type - Remote controller Remote controller holder installationFUJITSU
ASYG14KETA Air Conditioner Wall Mounted Type - Remote controller holder
installation

Battery loading and remote controller preparation(R03/LR03/AAA x 2FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Battery
loading

1 ~ 3 Put batteries as shown in the figure above.
4 Press to start clock setting.
5 Press to set day of the week (Monday to Sunday).

  • By pressing the time indicator can be chanaed from a 24-hour to a 12-hour clock.
    6 Press to continue.
    7 Press to set the clock.
    Press the buttons to change the clock by a minute.
    Press down the buttons to change the clock by 10 minutes.
    8 Press to complete the setting.
    Be close fo the indoor unit. If you press the button from a distance, settings may not be properly sent.

NOTES:

  • Use specified type of batteries only.
  • Do not mix different types or new and used batteries together.
  • Batteries can be used about 1 year in ordinary use.
  • If the remote control range noticeably shortens, replace the batteries, and press as shown in page 4.

NAME OF PARTS

CAUTION
For appropriate signal transmission between the remote controller and the indoor unit, keep the signal receiver away from the following items:

  • Direct sunlight or other strong lights
  • Flat-panel television screen In rooms with instantaneous fluorescent lights, such as inverter type ones, the signal may not be transmitted properly. In such a case, consult the store of purchase.

3.1. Indoor unit

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Indoor
unit

*1) Before starting operation, make sure that the intake grille is closed completely. Incomplete closing may affect the proper function or performance of the product.

*2) Indicator lamps light in the following conditions. It cannot see when the indicator lamp is off.

| Name| Color| Operation or condition
---|---|---|---
| Operation| Green| Normal operation
| Timer| Orange| Timer operation
| Economy| Green|

Economy operation 10 °C Heat operation

|

W-LAN

(optional)

| Orange| W-LAN control is active.

3.2. Remote controller

When you use the optional remote controller, the appearance and the operation procedure may differ.
For details, please refer to the operating manual of each remote controller.
: The setting must be done while the setting screen is displayed for each function.
: The button is controllable only when the air conditioner is operating.
: The instruction is relating to the W-LAN control (optional).

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Signal
transmitter

BASIC OPERATIONS

◼ 3 steps to start operation

  1. Press to start or stop the operation.

  2. Press to select the operation mode.
    The operation mode changes as follows.FUJITSU ASYG14KETA Air Conditioner
Wall Mounted Type - changes

  3. Press to set the desired temperature.

The temperature changes by 0.5 °C increments

Temperature setting range

Auto/Cooling/Dry|  18.0 to 30.0 °C
Heating| 16.0 to 30.0 °C

NOTES:

  • In the Cooling or Dry mode, set the temperature lower than the current room temperature.

  • In the Cooling mode, the indoor unit fan may stop from time to time to perform Fan control for energy saving that enables power-saving operation by stopping the rotation of the indoor unit fan when the outdoor unit is stopped. In initial setting, this function is activated.
    To deactivate the function, consult the installer or authorized service personnel.

  • In the Heating mode,
    -set the temperature higher than the current room temperature.
    – at the beginning of the operation, the indoor unit fan rotates at very low speed for 3-5 minutes.
    -the Automatic defrosting operation overrides the Heating operation when necessary.

  • In the Fan mode, temperature control is not available.

◼ Temperature unit switching

  1. Press until only the clock is displayed.

  2. Press down for more than 5 seconds.
    The current temperature unit will be displayed. (Factory setting: °C)

  3. Press to switch the temperature unit. (°C ⇔ °F)

  4. Press to finish the setting.
    If you do not press the button for 30 seconds, the displayed temperature unit will be set

AIRFLOW SETTINGS

5.1. Fan speed setting

Press to control the fan speed.
The fan speed changes as follows.FUJITSU ASYG14KETA Air Conditioner Wall
Mounted Type - changes 1

When AUTO is selected, the fan speed depends on the operating condition
To increase the air cleaning effect, set the fan speed to High.
5.2. Air flow direction setting
For details of the airflow ranges, refer to “Airflow direction range”.

◼ Vertical air flow direction setting
Press to adjust the vertical airflow direction.
Horizontal air flow direction setting

CAUTION
Before you adjust the horizontal airflow direction, make sure that the vertical airflow direction louver has been stopped completely.
** Adjust two knobs by hand.
◼** Swing operation setting
Press to start/stop the Swing operation.

NOTES: The Swing operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped.

Air flow direction range

Vertical air flow direction

Change by

|
---|---

Swing operation by

Cooling, Dry 1

|
Heating|

Fan *

|

* The Swing operation range depends on the airfl ow direction set before the Swing operation.

NOTES:

  • Do not adjust the airfl ow direction louvers by hand.
  • In the Auto or Heating mode, the airflow direction stay position 1 for a while from the start of the operation.
  • In the Cooling or Dry mode, position 1-3 is recommended to prevent condensation drips damaging your property. If position 4-6 keeps for  30 minutes or more in these modes, the airflow direction changes toposition 3 automatically.
  • When using the mobile app (optional W-LAN control is necessary), the vertical airflow can be selected from 4 positions

TIMER OPERATIONS

NOTES: When [] indicator on the indoor unit blinks, set the clock and timer again. This blinking shows that the internal clock go wrong due to an interruption of the power supply. (Refer to page 9.)
Timer setting procedure

Before setting the timer, please adjust the clock. (Refer to “remote controller preparation”)

  1. Press .
    on the remote controller display will blink.

  2. Press to choose timer operation.

The timer operation will change as follows:

Weekly timer

|

Enables you to set operation schedules up to 4 setting for each day of the week.

---|---

On timer

|

Starts the operation at your desired time.

Off timer

|

Stops the operation at your desired time.

Program timer

|

Operates as the combination of the On timer and Off timer.

Sleep timer

|

Supports your comfortable sleep by moderating the air conditioner operation gradually.

  1. Press .

  2. Set each timer operation.
    For details, refer to the following instructions of each timer setting .

  3. Press .to complete the timer setting.

Be close to the indoor unit.
• To cancel the timer setting during the procedure, press again.

6.1. Weekly timer

◼ Setting details

  1. Select Weekly timer in step 2 of “Timer setting procedure”.

  2. Press to select the program number and the day of the week.
    Selected program number (1~4) and the day of the week will blink.

MO Monday
TU Tuesday
WE Wednesday
TH Thursday
FR Friday
SA Saturday
SU Sunday

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Program
number

  1. Press .

  2. Press to choose the timer operation.FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - timer operation

  3. Press .

  • When you chose “Without a timer” in step 4, the setting display will return to step1.

    1. Press to set on time or off time.

    2. Press .

  • When you chose “Off timer” in step 4, the setting display will return to step 1.

    1. Press to set the temperature.
      Temperature setting range

Auto, Cooling, or Dry mode:

|

18.0 to 30.0 °C

*Even if you set to 10.0, 16.0-17.5 °C, the air conditioner will run at 18.0 °C.

---|---
Heating mode:|

10.0 or 16.0 to 30.0 °C

  1. Press .

The setting display will return to step 1.

  1. Press to complete the setting.

Be close to the indoor unit.
NOTES: [ ] indicator on the indoor unit will not turn on even if the setting is complete.

  • If you want to return the previous step, press  .

  • To check the schedule, use to browse the Weekly timer settings in step 1.
    To finish checking, press .

  •  To deactivate the Weekly timer, press while is shown on the remote controller display.
    The indicator will disappear.

NOTES:

  • The operation modes will be the same as the mode at the last time operation was stopped, so Cooling → Heating → Cooling → Heating type of operations cannot be set automatically.

  • If you set the On timer and Off timer on the same time, the On timer will work.

  • If two On timers are set on the same time, the air conditioner will run in the order of the program number.

  • You cannot the Weekly timer and the other timers simultaneously. If you use the On/Off timer, the Program timer, or the Sleep timer while the Weekly timer is activated, the Weekly timer will be deactivated. In such a case, activate the Weekly timer after the other timer finishes.

  • If the wired remote controller (optional) is connected, this function is restricted

◼ Examples of Weekly timer

Example 1

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Example
1

Example 2: You can specify temperature settings using the On timer in the Weekly timer.

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Example
2 6.2. On timer or Off timer

  1. Select On timer or Off timer in step 2 of “Timer setting procedure”.
  2. Press  to set on time or off time.
    Pressing the button: The time will change by +5/-5 minutes.
    Pressing down the button: The time will change by +10/-10 minutes.
    • To deactivate the On/Off timer, press while is shown on the remote controller display.
    The indicator will disappear.

6.3. Program timer

  1. Set On timer and Off timer. (Refer to “6.2. On timer or Off timer”).
  2. Select Program timer in step 2 of “Timer setting procedure”.
    The timer whose setting time is closer to the current time works first.
    The order of the timer operation is displayed as follows:

Timer|

Indicator on the remote controller display

---|---

On→Off timer

|

Off→On timer

|

NOTES: You can set the Program timer only within a span of 24 hours.
6.4. Sleep timer

  1. Select Sleep timer in step 2 of “Timer setting procedure”.

  2. Press to set the time until the operation stops.

Each time you press the button, the time changes as follows: FUJITSU
ASYG14KETA Air Conditioner Wall Mounted Type - Sleep
timer

  • To deactivate the Sleep timer, press while is shown on the remote controller display.
    The indicator will disappear.

During the Sleep timer operation, the setting temperature changes as the following figure.

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - In Heating
mode

After the set time has elapsed, the air conditioner operation turns off.

ENERGY SAVING OPERATION

7.1. Economy operation

It saves more electricity than other operation modes by changing the set temperature to a moderate setting.
**** Press to activate/deactivate the Economy operation.

[ ] indicator on the indoor unit will turn on.

Operation mode|

Room temperature

---|---
Cooling/Dry|

 Few degrees higher than the set temperature

Heating|

Few degrees lower than the set temperature

NOTES :

  • In the Cooling, Heating, or Dry mode, the maximum output of this operation is approximately 70 % of usual operation.
  • This operation cannot be performed during the temperature monitoring by the Auto mode.

OTHER OPERATIONS

8.1. Powerful operation

In the Powerful operation, the air conditioner will operate at maximum power and strong airflow to cool down or warm up the room quickly.

NOTES: In multiconnection, this function cannot be used.
**** Press to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned off automatically in the following situations:

  • The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling, Dry, or Heating mode.
  • 20 minutes after the Powerful operation has started.

NOTES:

  • The airflow direction and the fan speed are controlled automatically.

  • The Powerful operation cannot be performed simultaneously with Economy operation.
    The Powerful operation overrides the following operations. If the following operations are set, they will start after the Powerful operation finishes.
    -Outdoor Unit Low Noise operation
    -Energy Saving program

  • If the wired remote controller (optional) is connected, this function is restricted.

8.2. Outdoor Unit Low Noise operation

The Outdoor Unit Low Noise operation lowers noise from the outdoor unit. During this operation, the rotation number of the compressor decreases and the outdoor unit fan rotates slowly.

NOTES: In multi connection, this function cannot be used.
**** Press to activate/deactivate the Outdoor Unit Low Noise operation.
While the Outdoor Unit Low Noise operation is activated, on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned off.

NOTES:

  • This operation cannot be performed simultaneously with the Fan mode, Dry mode, and Powerful operation.
  • If the wired remote controller (optional) is connected, this function is restricted.

8.3. 10 °C Heat operation

10 °C Heat operation maintains the room temperature at 10 °C so as to prevent the room temperature to drop too low
**** Press to activate the 10 °C Heat operation.

The indoor unit will emit 1 short beep and [ ] indicator on the indoor unit will turn on.
**** Press to turn off the air conditioner.

[ ] indicator will turn off.

NOTES:

  • During the 10 °C Heat operation, only is valid.
  • When the room temperature is warm enough, this operation will not perform.
  • If the wired remote controller (optional) is connected, this function is restricted.

SETTINGS ON INSTALLATION

9.1. Remote controller custom code setting

By setting custom code of indoor unit and remote controller, you can specify the air conditioner which the remote controller controls.

When two or more air conditioners are in the room and you wish to operate them separately, set the custom code (4 selections possible).

NOTES: If custom codes is different between the indoor unit and the remote controller, the indoor unit cannot receive a signal from the remote controller.

How to set the remote controller custom code

  1. Press until only the clock is displayed on the remote controller display.

  2. Press and hold for more than 5 seconds.
    The current custom code will be displayed (initially set to A).

  3.  Press to change the custom code between A↔B↔C↔D

  • Match the custom code on the display to the air conditioner custom code. 4. Press again.
    The custom code will be set.
    The display will return to the clock display.

    • To change the air conditioner custom code, contact an authorized service personnel (initially set to A).
    • If you do not press any buttons for 30 seconds after the custom code is displayed, the display returns to the clock display. In this case, repeat the setting from step 2.
    • Depending on the remote controller, the custom code may return to A when replacing the batteries. In this case, reset the custom code as necessary. If you do not know the air conditioner custom code, try each code until you find the code which operates the air conditioner.

CLEANING AND CARE

CAUTION

  • Before cleaning this product, be sure to turn it off and disconnect all the power supply.
  • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
  • If the filter cleaning involves high-place work, please consult the authorized service personnel.
  • Do not touch the aluminum fins of heat exchanger built-in the indoor unit to avoid personal injury when you maintain the unit.
  • Do not expose the indoor unit to liquid insecticides or hair sprays.
  • Do not stand on slippery, uneven or unstable surfaces when you maintain the unit.

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type -
filter

The frequency of the cleaning is as shown in the following table.

What to do Frequency|
---|---
Cleaning indoor unit body|  When you notice
Cleaning air filter| Every 2 weeks
Cleaning Ion deodorization filter| Every 3 months
Replacing Apple-catechin filter (Model name: UTR-FA16)
Replacing Ion deodorization filter (Model name: UTR-FA16-2)| Every 3 years

  • The air cleaning filters are sold separately. When you replace them, please contact the store of purchase.

Cleaning indoor unit body
NOTES:

  • Do not use water hotter than 40 °C.
  • Do not use scouring cleanser, volatile solvents such as benzene or thinner.
  1. Wipe the indoor unit body gently with a soft cloth moisten with warm water.
  2. Wipe the indoor unit body gently with a dry and soft cloth.

Cleaning air filter

  1. Open the intake grille until it snaps.FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - grille

  2. Remove the air filters.
    Lift up the air filters’ handle, disconnect the two lower tabs, and pull out.FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type -
disconnect

  3. Remove the dust in either of the following ways.

• Cleaning with vacuum cleaner.

• Washing with mild detergent and warm water. After washing, dry the air filters thoroughly in shade.

  1. Replace the air filters.
    Align the sides of the air filter with the panel, and push in fully.

Make sure to the two lower tabs are returned to their holes in the indoor unit properly.

  1. Close the intake grille.
    Press 6 places on the intake grille to close it completely.

NOTES: If dirt accumulates on the air filter, airflow will be reduced, operating efficiency will lower, and the noise will increase

Cleaning Ion deodorization filter and Replacing Apple-catechin filter

  1. Remove the air filters. Refer to steps 1 ~ 2 of “Cleaning air filter”.

  2. Remove the air cleaning filters from the air cleaning filter holder.

  3. Flush the Ion deodorization filter (light blue) with high- pressure hot water until the surface of the filters are covered with water.

  4. Wash the Ion deodorization filter with diluent neutral detergent.
    Do not ream or rub, otherwise the deodorizing effect may decrease.

  5. Rinse the Ion deodorization filter with water flow.

  6. Dry the Ion deodorization filter in shade.

  7. Remove the Apple-catechin filter (light green) from the air cleaning filter holder.

  8. Set the new or washed air cleaning filters into the air cleaning filter frames.
    NOTES: Use the Apple-catechin filter as soon as possible after opening the package. The air cleaning effect decreases when the filters are left in the opened package.

  9. Install the air cleaning filter holders to the air filters.
    Engage the 4 hooks at the rear of the air cleaning filter frame with the latch at both ends of the air filter.

  • Take care that the air cleaning filter does not project beyond the frame. NOTES: Take care that the air cleaning filter does not project beyond the frame.

    1. Replace the air filters and close the intake grille. Refer to steps 4 ~ 5 of “Cleaning air filter”.

Replacing Ion deodorization filter

  1. Remove the air filters. Refer to steps 1 ~ 2 of “Cleaning air filter”.
  2. Remove the Ion deodorization filter (light blue) from the air cleaning filter holder.
  3. Install the new Ion deodorizing filter.

Removing and installing intake grille

◼ Removing intake grille

  1. Open the intake grille until it snaps.

  2. Pull the mounting shafts while keeping the intake grille in a horizontal position.

◼ Installing intake grille

  1. While holding the intake grille horizontal, set the left and right mounting shafts into the pillow blocks at the top of the front panel.
    Insert the shaft until it snaps to latch each shaft properly.

  2. Close the intake grille.

  3. Press 6 places on the intake grille to close it completely.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the Fan mode operation for half a day to dry the internal parts thoroughly before the normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may reduce the performance even if you have maintained the unit properly.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
Filter indicator reset (Special setting)
This function can be used if set correctly during installation. Please consult authorized service personnel in order to use this function.
**** Clean the air filter when the indicator lamp show the following:

Indicator lamp|

Blinking pattern

---|---
|

Blinks 3 times, at intervals of 21 seconds

After cleaning, reset the filter indicator by pushing FUJITSU ASYG14KETA Air
Conditioner Wall Mounted Type - Symbol 63on the indoor unit for 2 seconds or less.

GENERAL INFORMATION

◼ Heating performance

This air conditioner operates on the heat-pump principle, absorbing heat from air outdoors and transferring that heat to the indoor unit. As a result, the operating performance is reduced as outdoor air temperature drops.

If you feel that the heating performance is insufficient, we recommend you to use this air conditioner in conjunction with other kinds of heating appliance.

◼ Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost may form on the outdoor unit during the heating operation, and it could reduce the operating performance of the product.
For frost protection, a microcomputer-controlled automatic defrost function is equipped in this air conditioner.

If frost forms, the air conditioner will temporarily stop, and defrost circuit will operate briefl y (maximum of 15 minutes.)

[I] indicator on the indoor unit blinks during this operation. If frost forms on the outdoor unit after the Heating operation, the outdoor unit will stop automatically after it operates for a few minutes. Then the Automatic defrosting operation starts.

◼ Auto-restart function

In event of power interruption such as a blackout, the air conditioner stops once. But it restarts automatically and performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting down of the timer will be reset.

After the power supply is resumed, [ ] indicator on the indoor unit blinks to notify you that there has been a timer fault. In such a case, reset the clock and timer settings.

◼ Malfunctions caused by other electrical devices

Use of other electrical appliances such as an electric shaver or nearby use of a wireless radio transmitter may cause the malfunction of the air conditioner.

If you encounter such a malfunction, turn off the circuit breaker once.
Then turn it on again, and resume operation by using the remote controller.

Indoor unit temperature and humidity range

Permissible ranges of temperature and humidity are as follows:

Indoor temperature Cooling/Dry [°C] 18.0 to 30.0
Heating [°C] 16.0 to 30.0
Indoor humidity [%] 80 or less *1)

*1) If the air conditioner is used continuously for many hours, water may condense on the surface and drip.

  • If the unit is operated under the conditions except the permissible temperature range, the air conditioner operation may stop because of the automatic protection circuit working.
  • Depending on the operating conditions, the heat exchanger may freeze, causing water leakage or other malfunction (in the Cooling or Dry mode).

◼ Other information

  • Do not use the air conditioner for any purpose other than room cooling/dry, room heating or fan.
  • For the permissible ranges of temperature and humidity for the outdoor unit, refer to the outdoor unit installation manual.

OPTIONAL PARTS

12.1. Wired remote controller
The optional wired remote controller can be used.
You can use wired and wireless remote controller together.
However, some functions of the wireless remote controller are restricted.
If you set the restricted functions, beeping sound will be heard, [l], [ ] and [ ] indicator on the indoor unit will blink.

When using together with wired remote controller (2-wired type)
  • Weekly timer operation
  • Powerful operation
  • Outdoor Unit Low Noise operation
  • 10 °C Heat operation

You can use wired remote controller and W-LAN control (optional).

However, some operations from the mobile app are restricted.
Multiple remote controller
You can connect two wired remote controllers to one air conditioner.
Either remote controller can control the air conditioner.
However, the timer functions cannot be used by the secondary unit.
12.2. Group control
One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings.
You cannot use group control and W-LAN control together.
12.3. W-LAN control
NOTES: If you use the external input/output (optional) , W-LAN control cannot be used.
For how to operate the mobile app, refer to the operating manual of the mobile app.
Write down the SSID and the PIN code to the following table.

FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Connection
port

Information on W-LAN adapter****

SSID|
---|---
PIN|

Google Play is a registered trademark of Google Inc.

App store is a service mark of Apple Inc., registered in the U.S. and other countries.

Setting to use W-LAN control

Step 1. Application software installation

  1. Open “Google Play” or “App Store” depending on the type of your smartphone or tablet PC.
  2. Search for “FGLair”. 
  3. Install the application software (mobile app) following the instructions on your screen.

Step 2. User registration

  1. Open the installed mobile app.

  2. Register the user (with either a smartphone or tablet PC) by following the instructions in the create an account section of the mobile app.

Step 3. Installing W-LAN adapter

CAUTION

  • Be sure to turn off the power supply of the air conditioner when installing or removing this product to avoid the risk of electric shock.
  • Do not put fingers, sticks etc. in the connection part of this product and the connection slot of the indoor unit. Otherwise, electric shock or damage to the product may occur.
  • Do not standing on an unstable platform when installing or removing this product to avoid injury.
  1. Be sure to turn air conditioner off and to disconnect all the power supply.
  2. Open the intake grilleFUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - conditioner off
  3. Open the W-LAN adapter cover until it snaps.FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - W-LAN adapter
  4. Plug the W-LAN adapter into the connection slot of the indoor unit in the direction as shown in the figure.
  5. Close the W-LAN adapter cover and the intake grille.

Step 4. Air conditioner registration (pairing of W-LAN adapter)
NOTES:

  • Before starting this setting, reconnect the power supply of the air conditioner and wait for 60 seconds or more.
  • Check that the smartphone or tablet PC is linked to the wireless router you are connecting the air conditioner. The setting will not work if it is not connected to the same wireless router.
  • To control 2 or more air conditioners with the same smartphone or tablet PC, repeat the setup of the chosen mode.

****Register the air conditioner by following the instructions in the online manual on FUJITSU GENERAL web site.
www.fujitsu-general.com/global/support/
This operating manual describes only the setting procedure of the remote controller.

  1. Sign in to the mobile app.
  2. Open the side menu of the mobile app then tap [Help].
  3. Tap [W-LAN Support].

When the registration is completed, [ ] indicator on the indoor unit will turn on.

For reference
Setting procedure of the remote controller
NOTES: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display.

  1. Press until only the clock is displayed on the remote controller display.
  2. Press down on the remote controller for more than 5 seconds. will be displayed on the remote controller display,
  3. Press .
  4. Select using emote controller.
  5. Press .The indoor unit enters Manual mode and [ ] indicator on the indoor unit will blink.
    NOTES: If the registration is not be finished in several minutes, Manual mode is canceled and [ ] indicator turns off.
    In this case, please repeat the remote controller setting.

< Button mode>
Setting procedure of the remote controller:
NOTES: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display.

  1. Press until only the clock is displayed on the remote controller display.

  2. Press down on the remote controller for more than 5 seconds.
    will be displayed on the remote controller display.

  3. Press .

  4. Select using mote controller.

  5. Press .
    The indoor unit enters Button mode and [ ] indicator on the indoor unit will blink (on/off = 1sec/isec).
    When the W-LAN adapter find a connectable W-LAN access point, the blinking will become slowly (on/off = 2sec/0.5sec).
    NOTES: If the connection to W-LAN access point is not be finished in several minutes, Button mode is canceled and turns off.
    In this case, please repeat the remote controller setting.

Temporary deactivation of W-LAN

NOTES: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display.

  1. Press until only the clock is displayed on the remote controller display.

  2. Press down on the remote controller for more than 5 seconds.
    will be displayed on the remote controller display.FUJITSU ASYG14KETA Air
Conditioner Wall Mounted Type - Symbol 54

  3. Select OFF using emote controller. *FUJITSU ASYG14KETA Air Conditioner Wall Mounted Type - Symbol 55

  4. Press .
    [ ] indicator on the indoor unit will turn off.

  • If you want to activate W-LAN again, select QN in step 2.

Initialization (reset)

Initialize (reset) this product in the following situations:

  • Changing the wireless router
  • Disposing this product
  • Transferring this product to a third party

Unregister the air conditioner
Unregister the air conditioner by using the mobile app. (Refer to the operating manual of the mobile app for details.)
Initialization of the W-LAN adapter
NOTES: If you do not press any buttons of the remote controller for 60 seconds, the remote controller display will return to the original display.

  1. Press until only the clock is displayed on the remote controller display.

  2. Press down on the remote controller for more than 5 seconds.
    will be displayed on the remote controller display.

  3. Select using emote controller.

  4. Press .
    on the remote controller display will blink.

  5. Press .
    [ ] indicator on the indoor unit will turn off after blinking fast.

To continue use
If you or third party wishes to continue use of the product, follow the procedures in “Air conditioner registration (pairing of W-LAN adapter)’ to reconnect to a different wireless router.
NOTES: W-LAN setup is not possible if the previous owner did not unregister or initialize this product. In this case, please contact your authorized service personnel.

12.4. Multi-type air conditioner
This indoor unit can be connected to a multi-type outdoor unit.
The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.
Simultaneous Use of Multiple Units

  • When using a multi-type air conditioner, the multiple indoor units can be operated simultaneously, but when 2 or more indoor units of the same group are operated simultaneously, the heating and cooling efficiency will be less than when a single indoor unit is used alone.
    Accordingly, when you wish to use more than 1 indoor unit for cooling at the same time, the use should be concentrated at night and other times when less output Is required. In the same way, when multiple units are used simultaneously for heating, it is recommended that they be used in conjunction with other auxiliary space heaters, as required.

  • Seasonal and outdoor temperature conditions, the structure of the rooms and the number of persons present may also result in differences of operating efficiency. We recommend that you try various operating patterns in order to confirm the level of heating and cooling output provided by your units, and use the units in the way that best matches your family’s lifestyle.

  • lf you discover that 1 or more units delivers a low level of cooling or heating during simultaneous operation, we recommend that you stop simultaneous operation of the multiple units.

  • Operation cannot be done in the following different operating modes.
    If the indoor unit is instructed to do an operating mode that it cannot perform, [|] indicator on the indoor unit will flash (1 second on, 1 sec- ond off) and the unit will go into the standby mode.
    Heating mode and Cooling mode (or Dry mode)
    Heating mode and Fan mode

  • Operation can be done in the following different operating modes.
    Cooling mode and Dry mode
    Cooling mode and Fan mode
    Dry mode and Fan mode

  • The operating mode (Heating mode or Cooling (Dry) mode) of the out-door unit will be determined by the operating mode of the indoor unit that was operated first. If the indoor unit was started in the Fan mode, the operating mode of the outdoor unit will not be determined.
    For example, if indoor unit (A) was started in the Fan mode and then indoor unit (B) was then operated in the Heating mode, indoor unit (A) would temporarily start operation in the Fan mode but when indoor unit (B) started operating in the Heating mode, [|] indicator for indoor unit (A) would begin to flash (1 second on, 1 second off) and it would go into standby mode. Indoor unit (B) would continue to operate in Heating mode.

TROUBLESHOOTING

WARNING

In the following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel.
As long as the unit is connected to the power supply. it is not insulated from the power supply even if the unit is turned off.

  • Unit smells of something burning or emits smoke
  • Water leaks from the unit

Does not operate at all.

  • Has there been a power outage?
    In this case, the unit restarts automatically after the power supply is resumed. (Refer to page 9.)

  • Has the circuit breaker been turned off?
    Turn on the circuit breaker.

  • Has a fuse blown out or the circuit breaker been tripped?
    Replace the fuse or reset the circuit breaker.

  • Is the timer operating?
    To check or deactivate the timer setting, refer to page 5.

Poor cooling or heating performance.

  • Is the unit operating under the conditions except the permissible temperature range?
    In this case, the air conditioner may stop because of the automatic protection circuit working.

  • Is the air filter dirty?
    Clean the air filter. (Refer to page 8.)

  • Is the intake grille or outlet port of indoor unit blocked?
    Remove the obstructions.

  • Is the room temperature adjusted appropriately?
    To change the temperature setting, refer to page 5.

  • Is a window or door left opened?
    Close the window or the door.

  • Is the fan speed set to Quiet?
    To change the fan speed, refer to page 5.

  • Has the Outdoor Unit Low Noise operation been set?
    To stop the Outdoor Unit Low Noise operation, refer to page 7.

  • In the Cooling mode> Is direct or strong sunlight shining into the room?
    Close the curtains.

  • In the Cooling mode> Are there other heating apparatus or com-puters operating, or too many people in the room?
    Turn the heating apparatus or computers off, or set the tem-perature lower. (Refer to page 5.)

Airflow is weak or stops.

  • Is the fan speed set to Quiet?
    = To change the fan speed, refer to page 5.

  • Has the Fan Control for Energy Saving set? In this case, the indoor unit fan may stop temporarily while the Cooling operation.
    = To cancel the Fan control for energy saving, refer to page 7.

  • Have you just started the operation? In this case, the fan rotates at very low speed temporarily to warm up the internal parts of the unit.
  • Is the room temperature higher than the set temperature? In this case, the outdoor unit stops and the indoor unit fan rotates at very low speed.
  • In the Heating mode> Is [I] indicator blinking?
    In this case, the Automatic defrosting operation is working. The in- door unit stops for maximum of 15 minutes. (Refer to page 9.)

  • In the Dry mode> The indoor unit operates at low fan speed to adjust the room humidity, and may stop from time to time.

  • While the monitoring operation, the fan rotates at very low speed.

Noise is heard.

  • Is the unit operating, or immediate after stopping operation?
    In this case, refrigerant flowing sound may be heard. It may be particularly noticeable for 2-3 minutes after starting operation.

  • Do you hear a slight squeaking sound during the operation?
    This sound is produced by the minute expansion and contraction of the front panel caused by temperature change.

  • Do you hear a sizzling sound? This sound is produced by the Automatic defrosting operation. (Refer to page 9.)

Smell coming from the unit.

  • The air conditioner may absorb various smells generated from interior textile, furniture, or cigarette smoke. These smells may be emitted during the operation.

Mist or steam is emitted from the unit.

  • In the Cooling or Dry mode> A thin mist may be generated by condensation formed with sudden cooling process.
  • Is [|] indicator on the indoor unit blinking? In this case, steam may rise from the outdoor unit because of the Automatic defrosting operation. (Refer to page 9.)

Outdoor unit emits water.

  • The outdoor unit may emit water gener- ated by the Automatic defrosting operation. (Refer to page 9.)

The unit operates differently from the remote controller setting.

  • Are the batteries in the remote controller exhausted?
    Replace the batteries.

Operation is delayed after restart.

  • Has the power supply turned from Off to On suddenly?
    In this case, the compressor will not operate for about 3 minutes to prevent a blowout of the fuse.

Imediately stop operation and turn off the electrical breaker in following cases. Then consult authorized service personnel.

  • The problem persists even if you perform these checks or diagnostics.
  • On the indoor unit, [|] and [ ] blink while [ ] is blinking fast.
    NOTES: For any troubleshooting related to the W-LAN control, refer to the setting manual for W-LAN adapter or the mobile app installed in your smartphone or tablet PC.

State of indicator lamps
: The instruction is relating to the W-LAN control (optional).
Lighting pattern: Blinking, Any state

State Causes and solutions See page
Automatic defrosting operation
Please wait until finishing the defrosting (maximum of 15 minutes). 9
Filter indicator
Clean the air filter and reset the filter sign. 9
Demand response operation 7
Error code display
Consult authorized service personnel.
Timer setting error because of Auto restart
Reset the clock and timer settings. 9
Test run operation (for authorized personnel only)
Press to quit the test run. 3
The power to the wireless router is not on.
Check that the power to the wireless router is on. _

There is a possibility that the W-LAN adapter is not properly connected to the wireless router.
Disconnect the power supply to the air conditioner (via breaker or plug), and then re-connect.| 10
| The software of the W-LAN adapter is being updated.| –
During the air conditioner registration (pairing of W-LAN adapter)| 11
| Restricted function| 10

**Manual Auto operation and Filter indicator reset**
You can operate the air conditioner with FUJITSU ASYG14KETA Air Conditioner
Wall Mounted Type - Symbol 63 on the indoor unit.

Status Time to keep pressing Mode or operation
In operation More than 3 seconds Stop
Stopping 2 seconds or less Filter indicator reset
More than 3 seconds and less than 10 seconds Auto *1)
More than 10 seconds (Only for servicing.*2)) Forced cooling
  1. In multi connection, the operation mode follows the other indoor units.
  2. To stop the forced cooling, press this button or  on the remote controller.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FUJITSU User Manuals

Related Manuals