SGM P-10 Series Extremely Powerful All In One LED Fixture User Manual
- June 2, 2024
- SGM
Table of Contents
- SGM P-10 Series Extremely Powerful All In One LED Fixture
- Product Information
- Product Usage Instructions
- P-10 Series dimensions
- Safety information
- Overview
- Parts identification and terminology
- Preparing for installation
- Transportation
- Connecting AC power
- P-10 Connection diagram
- Using standalone operation
- Fixture properties
- Control menu
- Troubleshooting
- POI Permanent Outdoor Installation
- SGM Addressing Tool
- Accessories
- Maintenance
- Cleaning
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SGM P-10 Series Extremely Powerful All In One LED Fixture
Product Information
Specifications
- Model: P-10 Series
- Dimensions: All dimensions in millimeters and inches
- LEDs: 48 x 24W RGBW LEDs
- Output: High output design
- Applications: Suitable for multiple applications including wireless operation
Product Usage Instructions
-
Unpacking and Inspection
Unpack the device and inspect it for any damages that may have occurred during transportation. -
Transportation and Storage
Always use the supplied packaging or a suitable flight case for transportation and storage. Do not carry the fixture by connected cables or wires; use the provided handle. -
Installation and Rigging
All SGM fixtures, including the P-10 Series, have locking points at the base for installation and rigging. The distance between these points from center to center is always 106 mm.
FAQ
-
Q: Where can I find the latest version of the user manual?
A: You can visit the SGM official website at www.sgmlight.com for the latest version of the user manual. -
Q: What precautions should I take before operating the device?
A: Read and follow all safety instructions provided in the manual to prevent electric shock, burns, fire, and personal injury.
USER MANUAL
P-SERIES P-10 P-10 POI
P-10 Series dimensions
P-10
P-10 POI
All dimensions in millimeters and inches. Drawing not to scale.
- This manual covers installation, use, and maintenance of the SGM P-10 Series.
- A digital version is available at www.sgmlight.com, or upon request via support@sgmlight.com.
P-10 SERIES
USER MANUAL REV. E
- © 2021 SGM Light A/S®. The information in this document is subject to change without notice.
- SGM and all affiliated companies disclaim liability for any injury, damage, direct or indirect loss, consequential or economic loss, or any other loss occasioned by the use of, inability to use, or reliance on the information contained in this manual. The SGM logo, the SGM name, and all other trademarks in this document pertaining to SGM services or SGM products are trademarks owned or licensed by SGM, its affiliates, and subsidiaries.
- This edition applies to firmware version 0.22 or later.
- English edition.
Safety information
- WARNING!
- Read the following safety precautions carefully before unpacking, installing, powering, or operating the device.
- SGM fixtures are intended for professional use only. They are not suitable for household use.
- This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
DANGER! Risk of electric shock. Do not open the device.
- Do not open the device; there are no user-serviceable parts inside.
- Ensure that power is cut off when wiring the device to the AC mains supply.
- Ensure that the device is electrically connected to earth (ground).
- Do not apply power if the device or mains cable is in any way damaged.
- Do not immerse the fixture in water or liquid.
WARNING! Take measures to prevent burns and fire.
- Do not open the device; there are no user-serviceable parts inside.
- Ensure that power is cut off when wiring the device to the AC mains supply.
- Ensure that the device is electrically connected to earth (ground).
- Do not apply power if the device or mains cable is in any way damaged.
- Do not immerse the fixture in water or liquid.
WARNING! Take measures to prevent burns and fire.
- Install in a location that prevents accidental contact with the device.
- Install only in a well-ventilated space.
- Install at least 0.3 m (12 in.) away from objects to be illuminated.
- Install only in accordance with applicable building codes.
- Ensure a minimum clearance of 0.3 m (12 in.) around the cooling fans.
- Do not paint, cover, or modify the device, and do not filter or mask the light.
- Keep all flammable materials well away from the device.
- Allow the device to cool for 15 minutes after operation before touching it.
CAUTION: Exterior surface temperature after 5 min. operation = 49° C (120° F). Steady state = 59° C (138° F)..
WARNING! Take measures to prevent personal injury.
- Do not look directly at the light source from close range.
- Take precautions when working at height to prevent injury due to falls.
- For Permanent Outdoor Installations (POI), ensure that the fixture is securely fastened to a load-bearing surface with suitable corrosion-resistant hardware.
- For a temporary installation with clamps, ensure that the quarter-turn fasteners are turned fully and secured with a suitable safety cable.
- For elevated installations, secure the fixture with suitable safety cables and always comply with relevant load dimensioning, safety standards and requirements.
- The standard safety wire cable must be approved for a safe working load (SWL) of 10 times the weight of the fixture, and it must have a minimum gauge of 5 mm.
Before installing this product
Please visit the SGM official website at
www.sgmlight.com for the latest version of this
user manual/ safety information leaflet. Due to continuous improvements, the
instructions may change without notice. SGM always recommends the latest
available firmware
version from www.sgmlight.com.
-
External cleaning and visual inspection of the fixture
- All users of SGM fixtures should regularly clean those parts of the fixture directly exposed to the elements, such as the external housing and front lenses. Additionally, all owners of SGM fixtures must periodically check the external housing of the fixture for structural breaks, components in bad shape, cracked lenses, or loose screws. To ensure proper operation, but also to prevent the risk of potential accidents, do not use the fixture if the lens, housing, or power cables are damaged. If parts of the fixture appear to be missing, cease use immediately and contact SGM support.
-
Wiring and conduit/ containment
- SGM fixtures supplied with power and data cable leads are not intended for installation in permanently installed conduit or containment. When installing fixtures in a permanent installation, ensure cable leads are installed as a service loop to an appropriately rated junction box using suitable cable strain reliefs/ glands. All installed fixtures must be securely mounted and
service loop appropriately protected for installation location. All electrical wiring and connections should be completed by a
qualified electrician.
- SGM fixtures supplied with power and data cable leads are not intended for installation in permanently installed conduit or containment. When installing fixtures in a permanent installation, ensure cable leads are installed as a service loop to an appropriately rated junction box using suitable cable strain reliefs/ glands. All installed fixtures must be securely mounted and
-
Safety Precautions
When using electrical equipment, basic safety precautions should always be followed including the following:
1. Do not mount near gas or electric heaters.
2. Permanently installed equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
3. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
4. Do not use this equipment for other than intended use.
5. Refer service to qualified personnel or authorized service centers.
6. Do not look directly into the beam for long periods of time, when the fixture is on.
7. The fixture shall, under no circumstance, be covered with insulating material of any kind.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
Overview
The P-10/ P-10 POI is an RGBW LED fixture with high output, designed for multiple applications, including applications where wireless operation is essential.
P- 10 features:
- Powerful all-in-one 1250 W LED with 8 individually controllable segments, weighing around 20 kg.
- A wash light, a strobe light, a flood light, a pixel light, and a blinder with a non-fading continuous output.
- IP65-rated (standard) and IP66-rated (POI), enabling operation in all kinds of environmental settings and in temperatures from -40° C to 50° C.
- Fully adjustable CTC from 2,000K to 10,000K.
- Built-in wireless DMX and programmable standalone programs.
- Fully RDM implemented.
- Integrated handle eases the transport, rigging, and positioning of the fixture.
- Rubber feet meant for delicate surfaces, while at the same time prevent fixture from sliding.
- Optional accessories, such as barndoors and filter frames.
- Native 35° and 10° (POI only) front lenses with controlled field angle.
- Corrosion classified C5-M (marine) for coastal and offshore areas with high salinity (POI only).
Parts identification and terminology
- A: 48 x 24W LEDs
- B: P-10 Tilt lock
- C: Cooling fans
- D: Control panel (POI n/a)
- E: OLED Display (POI n/a)
- F: Dehumidifier and GORE-TEX membrane
- G: DMX in and out
- H: Power in and out
- I: Handle
- J: Barndoors attachment points
- K: Safety wire attachment point
- L: Holes for Omega bracket / M-10 screws (x6)
- M: P-10 POI Tilt lock (POI only)
- N: LED indicator (POI only)
Figure 1: Parts identification and terminology
Preparing for installation
Unpacking
Unpack the device and inspect it to ensure that it has not been damaged during
transport.
The P-10/ P-10 POI is shipped with:
- 1 x Power cable with IP connector, 2 m/ 78in. (standard only). In POI versions, a power cable with bare ends is supplied.
- Two Omega brackets with 1/4-turn fasteners (standard only).
- 1 x Spanner with magnet (POI only).
- 6 x M-10 screws (POI Only).
- Safety information leaflet.
Location/ application
The standard fixture is IP65-rated and is designed for both indoor and outdoor
events. This means that it is protected from:
- Dust, to the degree that dust cannot enter the fixture in sufficient quantities as to interfere with its operation.
- Lower pressure water jets from any direction.
The POI fixture is IP66-rated and designed for use in outdoor installations. This means that it is protected from:
- Dust, to the degree that dust cannot enter the device in sufficient quantities as to interfere with its operation.
- High pressure water jets from any direction.
When selecting a location for the device, ensure that:
- It is situated away from public thoroughfares and protected from contact with people.
- It has adequate ventilation.
- It is not immersed in water.
When using standard fixtures outdoors or in wet locations, ensure that:
- For wireless DMX or standalone operation, the protective cover is securely mounted in any unused DMX connectors in order to ensure the IP rating.
- For cabled DMX operation, the DMX out of the last fixture is terminated with a 120 ohm resistor between pin 2 and 3 (according to the RS485 standard), and the DMX out is properly sealed, in accordance with the ingress protection (IP) requirements. Note that a maximum of 32 fixtures can be connected to the same DMX link.
Transportation
-
Always use the supplied packaging or suitable flight case for transportation and storage. Never carry the fixture by connected cables or wires; use the handle.
-
Installing/ rigging the P-10 Series
-
All SGM fixtures have locking points at the base for installation and rigging. In both standard and POI fixtures, the distance between the points from center to center is
always 106 mm. -
While the base of the standard fixtures includes 1/4-turn fastener camlocks to mount the omega brackets, the POI products come with M-10 nuts for M-10 screws.
-
The standard P-10 may be installed in any orientation and it might take up to three omega brackets per fixture. Always use a minimum of two omega brackets to rig the fixture and lock the bracket with the 1/4-turn fasteners.
PLEASE NOTE!!
The 1/4-turn fasteners are only locked when turned fully clockwise.
NOTE: In POI fixtures, a customized bracket may have to be used to install the fixtures. See more about “Installation and rigging the P-10 POI” on page 17.
Rigging process
Start the standard rigging process by blocking the lower working area, and
make sure the work is performed from a stable platform.
- Check that the clamp is undamaged and can bear at least 10 times the weight of the fixture. Check that the structure can bear at least 10 times the weight of all installed fixtures, lamps, cables etc.
- Bolt the clamp securely to the omega bracket with a M12/ ½ bolt (min. grade 8.8) and a lock nut.
- Align the omega bracket with the two 1/4-turns in the base. Insert the fasteners into the base bracket, and turn both levers a full 1/4-turn clockwise to lock.
- Working from a stable platform, hang the fixture on a truss or other structure. Tighten the clamp.
- Install a safety wire that can bear at least 10 times the weight of the fixture. The safety wire attachment point is designed to fit a carabiner.
- Verify that there are no combustible materials, cables, or surfaces to be illuminated within 0.3 m (12 in.) of the fixture.
- Check that there is no risk of colliding between the head/ yoke and other fixtures or structures.
Figure 3 : Base with omega bracket
WARNING! Always secure an elevated fixture with a safety wire
Fasten a safety wire (not shown) between the load-bearing support structure and the safety wire attachment point on the device.
- The safety cable (not included in the package) must
- Bear at least 10 times the weight of the device (SWL).
- Have a minimum gauge of 5 mm.
- Have a maximum length (free fall) = 30 cm (12 in.).
CAUTION!
- Always use a safety wire of a grade AISI 316 steel.
- Make sure the slack of the safety wire is at a minimum.
- Never use the handle for secondary attachment.
Tilt Lock
The P-10 can be tilted from 0° – 120°.
In standard versions, there is no need for any special tools to adjust the
tilt angle. Take the following steps for adjusting the tilt in standard P-10:
- Loosen the two tilt knobs (one on each side) by turning them counter-clockwise.
- Adjust the tilt to the desired angle and hold it.
- Lock the position by re-tightening both tilt lock knobs clockwise.
If you feel resistance when tilting the fixture, you might not have loosened
the tilt lock knobs enough.
CAUTION!!
If the fixture has been operating, always allow it to cool for 15 minutes
before handling. Exterior surface temperature after 5 min. operation = 49° C
(120° F). Steady state = 59° C (138° F).
Angle indicator
- The P-10 comes with a scale function which eases the adjustment to the tilt desired.
- The angle indicator in the wheel shows the current angle of inclination.
- NOTE: In POI versions, SGM provides a POI Spanner with a pig-nose key for tilt adjustment. Either use the large or the small pig-nose key, depending on the type of fixture. See “POI Tilt lock” on page 17 to know more about the tilt lock in P-10 POI.
Connecting AC power
The P-10 Series can operate on any 100–277 V, 50/ 60 Hz AC mains power supply.
Connect a P-10 standard to AC power using the supplied power cable or similar
with a maximum of 20
A to ensure the correct ingress protection (IP rating).
The fixture must be grounded/ earthed and able to be isolated from AC power.
The AC power supply must incorporate a fuse or circuit breaker for fault
protection.
The power cable color coding is given in figure 7:
- Connect the black wire to live.
- Connect the white wire to neutral.
- Connect the green/ yellow wire to ground (earth).
For a temporary outdoor installation, the mains cable must be fitted with a
grounded connector intended for exterior use. For permanent installations,
have a qualified electrician to wire the mains cable directly to a suitable
branch circuit. The junction’s ingress protection (IP) rating must be suitable
for the location. Always use a junction box with a proper IP class suitable
for the environment. When installing standard type C circuit breakers, there
will be no limitations due to the fixture’s inrush current.
For assistance with alternative configurations, contact your SGM
representative.
NOTE: In POI versions, SGM supplies a power cable with bare ends. Connect
the fixture to power by mounting a power connector to the bare-ended mains
cable. Please refer to “Connecting DMX and AC power in POI” on page 18 for
connecting AC power in POI fixtures.
After connecting the P-10 to power, run the on-board test by selecting TEST →
AUTOMATED TEST in the menu, to ensure that the fixture and each LED are
functioning correctly. POI versions have to be tested through RDM.
-
PLEASE NOTE!
The protective caps must be securely mounted on any unused DMX connectors in order to maintain the ingress protection (IP-rating). -
CAUTION!!
Do not connect the fixture to an electrical dimmer system, as doing so may cause damage.
Configuring the device
- The P-10 can be set up by using the control panel and OLED multi-line display on the fixture’s head or through RDM.
- Please note: In POI versions, there is no display mounted in the fixture. The adjustments are made through RDM.
- See “RDM” on page 15 for more information.
- The OLED display is the human interface of the fixture as it displays the current status and menu of the fixture. The display panel can be used to configure individual fixture settings, check the fixture’s wireless status, confirm the firmware version, and read error messages. The complete list of the menu and all commands available are listed in “Control menu” on page 14.
- Before turning on the P-10, make sure the power in cable is properly connected. To turn off the device, simply disconnect power in cable. When the fixture is powered on, it boots and resets before displaying the currently selected operating mode and the DMX start address. Navigate through the menus and options using the arrow buttons, and select items using the ENTER button.
Using the display panel
- Press the ‘ENTER’ button to access the menu or make a selection.
- Press the arrow buttons to scroll up and down in the menus.
- Press the ‘ESC’ button to take a step back in the menu.
Display
-
A – Operational mode (quick color, standalone, or DMX mode).
-
B – DMX address.
-
C – External data indicator (if DMX control is active).
-
D – External data protocol (CRMX™ or DMX).
-
E – Next available DMX address depending on the fixtures DMX footprint.
-
Note: the fixture is set by default to be controlled in DMX mode.
-
Error Indicator
-
If any errors are detected, the message ‘ERR’ will be flashing in the display for easy detection. To read the error message select ENTER → INFO → ERRORS in the menu.
-
Shortcuts
- ESC + ENTER : Press ENTER to confirm factory defaults.
- ESC + UP: Display OFF.
- ESC + DOWN: Set up new DMX address; keep ESC and press ENTER to confirm.
- UP + DOWN arrows simultaneously = flip the display upside-down.
-
Connecting to a DMX control device
The P-10 Series is controllable using a DMX control device, and it can be connected using either a DMX cable, or via the fixture’s built-in CRMX wireless receiver system. -
When using a cabled DMX system, connect the DMX-In cable to the input connector and the DMX-Out cable to the output, both on the rear of the fixture’s base (chassis mounted male and female 5-pin
-
XLR plugs). For outdoor installations, use only IP-rated XLR connectors suitable for outdoor use.
-
In standard fixtures, if using a wireless DMX system, remember to use the protective caps in any unused DMX connector in order to maintain the fixture’s IP rating. For POI versions, please refer to
-
“Connecting DMX and AC power in POI” on page 18.
-
NOTE: SGM fixtures provide a passive DMX Thru signal as DMX Out, instead of an active output signal.
Connecting a wireless transmitter
- The P-10 is designed to look for wireless transmitters in ‘connect’ state when this option is not yet enabled.
- To connect the P-10 to a wireless transmitter:
- Log off the currently paired wireless transmitter – see below “Disconnecting a wireless transmitter”.
- Press the connect button on the wireless transmitter.
- Confirm that the fixture has paired with the wireless transmitter.
Note: for POI versions, refer to “Connecting a wireless transmitter in
POI” on page 18.
Disconnecting a wireless transmitter
To disconnect the fixture from the currently paired wireless transmitter, go
to SETTINGS → WIRELESS DMX → LOG OFF in the
menu.
- Note: for POI versions, refer to “Disconnecting a wireless transmitter in POI” on page 18.
Signal priority
-
The P-10 can be paired to an active wireless transmitter simultaneously, when connected to a cabled DMX. The fixture will prioritize
cabled DMX over wireless DMX. -
The active input type is displayed under the wireless signal strength indicator. The signal strength can be also checked via RDM data by using an external RDM device (e.g. the SGM A-4).
-
NOTE: In POI version with wireless, the DMX signal strength can only be checked through RDM.
-
Configuring the device for DMX control
About DMX
- The P-10 Series can be controlled using signals sent by a DMX controller on a number of DMX channels.
- DMX is the USITT DMX512-A standard based on the RS-485 standard. The signal is sent as DMX data from a console (or a controller) to the fixtures via a shielded twisted pair cable designed for RS-485 devices.
- The cables can be daisy chained between the fixtures, and up to 32 fixtures can be connected to the same DMX link. Up to 300 me-ters (1000ft.) of cable is achievable with high quality DMX cables. In installations with standard fixtures, remember that all DMX links must be terminated in the last fixture by connecting a DMX termination plug to the last fixture´s 5 pin DMX-Out connector.
- PLEASE NOTE :
- Standard microphone cable is not suitable for transmitting DMX.
- Up to 32 fixtures can be linked to the same DMX chain. Additional fixtures will overload the link.
- The last fixture must always be fitted with a DMX termination plug to the fixture’s DMX out.
DMX Start address
- The P-10 Series can be operated in different DMX modes. For any of the modes, the first channel used to receive data from a DMX control device is known as the DMX start address.
- For independent control, each P-10 must be assigned its own DMX start address. For example, if the first P-10 is set to 6ch CTC DMX mode with a start DMX address of 113, the following P-10 in the
- DMX chain should then be set to a DMX address of 119. As the first fixture uses all the first 6 DMX channels, including channel 113, the next available channel is 119 (113+6=119 >> 119).
- If two or more fixtures of the same type have the same DMX address, they will behave identically. Incorrect settings will result in unpredictable responses from the lighting controller. Address sharing can be useful for diagnostic purposes and symmetrical control.
Set/ edit DMX address
- The DMX address is shown on the OLED display in the control panel. To change the address setting, press the up and down arrows. When the desired address is displayed, press ENTER to save the setting. For your convenience, the next available DMX address is displayed to the right.
- Note that channel spacing is determined by the number of channels of the DMX mode.
- See instructions on how to use the display panel in “Configuring the device” on page 9.
- The P-10 Series also offers the option to set the DMX address through RDM.
- NOTE: POI versions are only addressable via RDM. See “POI Permanent Outdoor Installation” on page 16.
DMX modes
- The P-10 Series operates in different modes.
- All DMX charts are available at www.sgmlight.com under the respective products or upon request via support@sgmlight.com.
P-10 Connection diagram
Using standalone operation
-
Standalone operation is not running when the fixture is connected to a control device, but when it is pre-programmed with a series of up to 24 scenes, playing continuously in a loop. Up to three stand alone programs can be defined and run from the menu, and one of the programs can be set to run by default whenever the fixture is powered on.
-
Each of the three available stand-alone programs contains 24 user-definable scenes with its own RGB and shutter settings.
-
Each scene has a definable fade-in time for the transition from one color to the next, and a wait (static) time of up to 120 minutes and 59 seconds.
- To define a standalone program, press ENTER → MANUAL → EDITOR.
-
The standalone mode of the fixture’s startup is enabled by selecting:
- ENTER → SETTINGS → STARTUP MODE → SELECT STARTUP MODE → STANDALONE.
-
To select the fixture’s startup program, press:
- ENTER → SETTINGS → STARTUP MODE → STARTUP PROGRAM.
-
The chosen program will run its length cyclically whenever the fixture is powered on.
-
To run an internal program, go to:
- ENTER → MANUAL → RUN PROGRAM.
-
To stop an active internal program, go to:
- ENTER → MANUAL → STOP PROGRAM.
Please note: In POI versions, configuring the fixtures can only be done
through RDM.
Setting a static color manually
- The P-10 can be configured to display a predefined and static color.
- To set up a static color select ENTER → MANUAL → QUICK COLOR.
- Note that once the MANUAL → QUICK COLOR settings are changed, the fixture is set, by default, to automatically start in quick color mode whenever it is powered on. This can be reset through the menu SETTINGS → STARTUP MODE → SELECT STARTUP MODE.
- The current quick color program can always be stopped by going to:
- ENTER → MANUAL → STOP PROGRAM.
- See “Control menu” on page 14 for detailed information about the manual menu.
- Please note : In POI versions, configuration of the fixtures can only be done through RDM.
Fixture properties
Factory default
When restoring factory defaults in the P-10 Series, the following settings
will be set:
- Set DMX address to 1.
- Set 6 Channel CTC DMX mode.
- Set screensaver to Dimed.
- Set flip screen to not-flipped.
- Disable Startup Programs.
- Set all Quick Color values to zero.
- Disable DMX Loss.
- Disable High Speed mode.
- Set all values in Manual Programs to zero.
- Set Fan mode to Standard.
Effects
Colors and LED Panels
The P-10 Series features 48 high-power RGBW 24W LEDs, divided into eight
individually controllable segments, which generates wide-ranging color effects
and pixel-mapping combinations for creative lighting designs.
- Color temperature correction
- The P-10 Series offers seamless CTC (color temperature correction) control from 2,000° Kelvin – 10,000° Kelvin.
- Ultra high-speed strobe effect
- The ultra high-speed strobe effect generates random strobe and pulse effects with variable speed.
- Beam angle
- The P-10 Series offers a narrow beam angle that can be modified using different optional magnetic holographic filter frames and barndoors, or native individual front lenses (POI only).
- Individual fixture settings
- Flipping the OLED display (POI n.a.)
- If the fixture is installed hanging upside down, it might be useful to flip the display so that it is easier to read.
- To flip the display, press ENTER and select SETTINGS → FLIP DISPLAY, or press the up and down buttons on the control panel at the same time.
- Setting the OLED display saver (POI n.a.)
- By default the OLED display dims down after a short period when the control panel is not in use. The display can also be set to turn off completely, especially when a pitch-black environment is required. Pressing any key will always turn on the display or restore it to normal brightness.
- To configure the display settings, press ENTER → SETTINGS → DISPLAY SAVER.
- NOTE: To avoid the risk of display deterioration caused by long term usage, it is recommended to select the setting → DISPLAY OFF.
- Setting the fan mode
- For operating environments where low-noise is a requirement or where the fixture will be operating in high temperatures, it is possible to adjust the default fan speed to low or high by going to
- SETTINGS → FAN MODE in the menu.
- NOTE: In POI version, the fan mode adjustment is possible through RDM.
Control menu
Level 1 | Level 2 | Level 3 | Function |
---|---|---|---|
Mode | Select Mode | – | Select DMX mode. |
Test | Automated Test | – | Initiate a self-test sequence. |
Display Test | – | Service use only. | |
Off | – | Stop test sequence execution. | |
Manual | Quick Color | Red | Static quick color – red mix (0-255). Sets fixture |
to quick color startup mode.
Green| Static quick color – green mix (0-255). Sets fixture to quick color
startup mode.
Blue| Static quick color – blue mix (0-255). Sets fixture to quick color
startup mode.
White| Static quick color – white mix (0-255). Sets fixture to quick color
startup mode.
Full color calibration| Enable or disable color calibration.
Macro Color| Macro color| Select macro color.
Macro intensity| Intensity level of the macro.
Run Program| 1, 2 or 3| Run internal sequence 1, 2 or 3.
Stop Program| –| Stop current running internal sequence or Quick Color.
Editor| Program| Currently selected program (1, 2 or 3).
Scene| Currently selected scene (1-24).
Red| Red value in currently selected scene (0-255).
Green| Green value in currently selected scene (0-255).
Blue| Blue value in currently selected scene (0-255).
Shutter| Shutter setting in currently selected scene (0-255). (According to
latest DMX chart).
Fade Time (Min.)| Fade-in (transition) time to current scene in min. (0-511).
Fade Time (Sec.)| Fade-in (transition) time to current scene in sec. (0-59).
Wait Time (Min.)| Wait (static) time in current scene in min. (0-998).
Wait Time (Sec.)| Wait (static) time in current scene in sec. (0-59).
Settings| Wireless DMX| Wireless log off| Send Log off command to the CRMX
System.
Signal strength| Display strength of the wireless connection.
Service PIN| –| –
Service menu| –| –
Factory Default| –| Reset the fixture to factory default settings.
Fan Mode| Standard| Adjust fan speed relative to internal fixture temperature.
Max Power| High fan speed for maximum cooling effect.
Silent| Low fan speed for quiet operation.
Display Saver| Display Dim| Dim the OLED display when the control panel is not
in use.
Display Off| Turn off the OLED display when the control panel is not in use.
Flip Display| Enable| Flip control panel display.
Disable| Select normal control panel display.
DMX Loss| DMX Hold| Select what happens when DMX signal is lost.
Quick color
Blackout
All ON
Startup Mode| Select Startup Mode| Default operating mode when fixture is
powered on:
- DMX (factory default).
- Stand-alone.
- Quick Color.
Startup Program|
- Stand-alone program 1, 2 or 3.
- Only used if the startup mode is set to “standalone”. Program 1 is default.
Info| Product Type| –| Displays product type.
Firmware Version| –| Displays installed firmware version.
Serial Number| –| Displays SGM serial #.
RDM ID| –| Displays RDM ID. (Unique RDM ID for identification )
DMX View| Up to 504 DMX addresses| Displays received DMX levels.
Temperatures| Mainboard| Displays fixture temperatures.
LED Left 1
LED Left 2
LED Left 3
LED Left 4
Level 1| Level 2| Level 3| Function
---|---|---|---
Info| Temperatures| LED Right 1| Displays fixture temperatures.
LED Right 2
LED Right 3
LED Right 4
Humidity head| Displays humidity in the head.
Wireless signal| Displays wireless signal strength.
Wireless paired| Shows if wireless is paired.
Light pwm| Displays light output level.
Voltage| Displays power supply voltage.
Power on time| –| Displays fixture total power on time.
LED On Time| –| Displays LED total power on time (R, G, B, W).
Errors| –| Displays error codes.
RDM
- Supported RDM functions
- The P-10 Series features support for various RDM functions.
- RDM (Remote Device Management) is a protocol enhancement to USITT DMX512 that allows bi-directional communication between the fixtures and the controller over a standard DMX line. This protocol will allow configuration, status monitoring, and management.
- An RDM controller is needed to get control over the supported parameters. See the tables below for supported RDM functions.
RDM functions
PID | Actions allowed | Name |
---|---|---|
0x0082 | – | Device Label |
0x0081 | – | Manufacturer Label |
0x00E0 | – | DMX Personality |
0x00E1 | – | DMX Personality description |
0x0200 | – | Sensor Definition |
0x0201 | – | Sensor Value |
0x0080 | – | Device Model Description |
0x0400 | – | Device Hours |
0x0051 | – | Parameter Description |
0x0501 | – | Display Level |
0x0500 | – | Display Invert |
0x0090 | – | Factory Defaults |
PID | Actions allowed | Name |
---|---|---|
0x1001 | – | Reset Device |
0x0120 | Slot Info | |
0x0121 | Slot Description | |
0x0122 | Default Slot Value | |
0x8626 | SET | CRMX Log Off |
0x8060 | GET | Serial Nr. |
0x8632 | GET/ SET | SMPS Calibration |
0x8625 | GET/ SET | FAN |
2=HIGH 3=FULL
0x8634| GET/ SET|
- 0=HOLD 1=WHITE
- 2=OFF 3=Q COLOR
Please note : The RDM controller communicates with the fixtures to show
only the available options for each RDM function. The table is subject to
change without notice.
Sensors
RDM enables various sensor readouts for remote device monitoring. See the
table below for sensors and sensor types.
Please note: The RDM controller communicates with the fixtures to show
only the available sensors for this fixture. The table is subject to change
without notice.
Name | Sensor Type |
---|---|
Mainboard | Temperature |
LED Left 1 | Temperature |
LED Left 2 | Temperature |
LED Left 3 | Temperature |
LED Left 4 | Temperature |
LED Right 1 | Temperature |
LED Right 2 | Temperature |
Name | Sensor Type |
--- | --- |
LED Right 3 | Temperature |
LED Right 4 | Temperature |
Humidity Head | Other |
Wireless Signal Strength | Other |
Wireless Paired | Other |
Light PWM | Other |
Voltage | Voltage |
Troubleshooting
Problem | Potential cause(s) | Remedies |
---|---|---|
Fixture does not respond or appears to be completely dead. | No power to the | |
fixture. | Confirm that the power is switched on, confirm that the cables are |
plugged in.
Main fuse is blown.| Contact SGM support or certified SGM service partner.
Fixture suddenly turned off.| Power was turned off.| Check the power supply,
switches and breakers.
Fixture suddenly stopped responding.| The wireless transmitter or connections,
was disconnected/
tampered with.
| Inspect the wireless transmitter and connections.
DMX cables was disconnected.| Inspect DMX cables.
Fixture operates irregularly/ abnormally.| DMX cable polarization is inverted
(pin 2 + 3).| Install a phase-inverter or replace cables.
DMX link is not terminated.| Install a XLR 120 ohm DMX termination at the end
of the DMX link (POI n.a.).
Corrupted DMX cable.| Replace or repair defective cables and/ or connectors.
The fixture operates an internal program.| Go to MENU → MANUAL → STOP PROGRAM.
A corrupted fixture generates noise/ disruptions on the DMX link.| Track and
isolate the corrupted fixture.
Color is uneven.| The minimum values is out of calibration.| Contact your
local SGM dealer or support@sgmlight.com.
The SGM Calibration Data set has been lost.| Contact your local SGM dealer or
support@sgmlight.com.
POI Permanent Outdoor Installation
- The SGM POI versions are designed for permanent outdoor installation and are IP66-rated. POI versions are designed for use in maritime and offshore environments, as per the CX/C5-M corrosion resistance class.
- Physical differences
- The POI version differs from the standard version by having fixed-chassis power and DMX cables, and heavy-duty cable glands. The display and control panel have been removed.
Configuration
-
The P-10 POI does not include a display, therefore it has to be configured through RDM (Remote Device Management). See “RDM” on page 15 for more information.
-
In P-10 POI, the DMX address and DMX mode can only be set through RDM. When addressing through USB powered DMX/ RDM devices, ensure DMX link is terminated, and keep a short cable length as much as possible.
-
Regarding the DMX modes for POI, they are the same as the P-10 standard. Visit www.sgmlight.com to see all DMX charts available under the respective product, or upon request via support@sgmlight.com.
-
PLEASE NOTE!!
-
Remote Device Management (RDM) requires a correct DMX cabled installation and termination.
-
When setting addresses through RDM and using USB dongles, disable the USB selective suspend to ensure a proper voltage on the DMX link. If any lag or trouble occurs when addressing, decrease the cable length range to <12 m. and only
address one fixture at a time. -
LED Indicator
-
The LED indicator is located on the fixture’s head (same place where the display is located in
standard P-10), and shows the current status of the fixture.
The LED indicator can have different colors and three possible stages: static, flashing, or off.- Solid Orange : Fixture is starting up.
- Blinking Green : Wireless and/ or wired DMX connected.
- Solid Green : No wireless or wired DMX connection.
- Blinking Red : Wireless and/ or wired DMX connected but Error(s) occurred.
- Solid Red : No wireless or wired DMX connection but Error(s) occurred.
- Off : fixture is off or indicator LED is set to auto dimming (set via RDM).
SGM Addressing Tool
- SGM provides a windows software tool designed to allow the user to address and configure the fixtures through RDM. Changing the settings is done in the exact same way as it is in the display.
- This tool is available for download at www.sgmlight.com, and has to be used with the SGM USB 5-Pin-XLR Uploader cable POI if the luminaire does not use XLR connectors in the DMX cable, or the
- SGM USB uploader cable if the luminaire uses XLR 5-pin DMX connectors (available from your SGM dealer).
POI Spanner
- The P-10 POI includes a spanner with a magnet, which function is to establish connection between the fixture and the wireless transmitter.
- The spanner also has two types of pig-nose keys used for tilt adjustment in
- POI fixtures. Depending on the type of fixture, either use the large or the small pig-nose keys.
- In P-10 POI devices the smallest pig-nose key is used for tilt adjustment.
POI Spanner POI Tilt lock
- The tilt angle in POI fixtures may be adjusted by using the small pig-nose key provided in the spanner.
- To adjust the tilt angle in P-10 POI, take the following steps:
- Make sure the fixture has cooled down before handling.
- Take the spanner and turn both tilt lock knobs (one on each side) counter-clockwise by using the small pig-nose key. Knobs are loosened by turning counter-clockwise.
- Tilt the fixture to the desired angle and hold it.
- Lock the position by tightening the tilt lock knobs clockwise with the same pig-nose key.
Installation and rigging the P-10 POI
- While the base of the standard products includes 1/4-turn fastener camlocks for omega brackets, the base of POI products comes with M-10 nuts for M-10 screws. The M-10 screws are included in the package in the same amount as the number of M-10 nuts at the base.
- The P-10 POI base has six M-10 nuts that can be used for installation and rigging. The SGM Omega bracket (not included) or a customized bracket is needed to install the fixture. Consider the dimensions below of the P-10 POI base for customized mounting bracket purposes.
- The SGM POI Omega bracket suited for M-10 holes can be ordered as an accessory. Contact your local SGM dealer for further information on correct POI-rated mounting.
Connecting DMX and AC power in POI
- DMX in and DMX out are in the same cable. See more in figure 19 about the SGM POI DMX cable.
- Power is wired as in the standard version. See “Connecting AC power” on page 9.
- For permanent installations, have a qualified electrician to wire the mains cable directly to a suitable branch circuit. The junction’s ingress protection (IP) rating must be suitable for the location.
- For a temporary installation, the mains cable may be fitted with a grounded connector intended for exterior use.
- PLEASE NOTE!!
- Standard microphone cable is not suitable for transmitting DMX.
- Up to 32 fixtures can be on the same DMX link. Additional fixtures will overload the link.
- The last fixture must always be fitted with a DMX termination plug to the fixture’s DMX out.
- SGM fixtures provide a passive DMX Thru signal as DMX Out instead of an active output signal.
P-10 POI connection diagram
Connecting a wireless transmitter in POI
In POI versions with wireless, it is necessary to pair the fixture with a new
transmitter (by default, the fixture is linked to the SGM factory
transmitter).
In order to do so, make sure the fixture is powered on before taking the
following steps:
- Take the spanner that comes with the fixture, place the magnet close to the LED indicator, and wait for 3 seconds. The LED indicator will blink orange for 1-2 seconds, before switching to static green again. The fixture can now be paired with a new transmitter.
- Go to the wireless transmitter and press “connect” or “link”. Now the external third-party transmitter and the internal SGM receiver should be linked together.
Repeat the process to link the fixture to another transmitter.
Disconnecting a wireless transmitter in POI
To disconnect the P-10 POI from the currently paired wireless transmitter,
simply hold the magnet for 3 seconds over the LED indicator. The LED indicator
blinks orange for 1-2 seconds, switching later to green again. The fixture is
now logged off.
Accessories
- The P-10 Series can be used with various accessories such as cables, barndoors, filter frames, and anti-glare shields.
- To get to know all the available P-10 accessories, go to www.sgmlight.com or contact your local SGM dealer.
Barndoors
The P-10 Series features 4-way barndoors. The barndoors are designed and
intended to be mounted on the fixture without the use of any tools.
To install the barndoors :
- Attach the lower plug-in pins to the bottom part of the P-10 front.
- Pull the two upper lock pins and fit the upper part of the barndoor in the P-10 head.
- Release the lock pins and check that they are correctly in place.
Filter frames
The P-10 Series features various optional, magnetic holographic filter frames:
- Wide angle (45°).
- Medium angle (19°).
- Elliptical wide angle horizontal (63°x12°).
- Elliptical wide angle vertical (12°x63°).
- Empty frame for optional filters.
- The type of filter is easily identified by the engraving in the corner of the filter.
- The filter frames are easily mounted due to their magnetic properties. To install them, it’s only required to position the filter frame in front of the light, and it quickly snaps into place.
- The frames are fitted with a safety wire to secure the frame to the yoke on the P-10.
- A filter frame can be mounted simultaneously with a barndoor.
PLEASE NOTE!!
The barndoors and the filter frames are not intended for permanent outdoor
installations.
-
Anti-glare shields
The P-10 Series supports two different types of optional anti-glare shields:- Full anti-glare shield – covers the full fixture’s opening.
- Half anti-glare shield – covers half of the fixture’s opening.
Using the anti-glare shields will remove any unwanted glare and reflections.
The anti-glare shields are easily mounted by removing the two tilt lock bolts,
one on each side of the fixture. Refit the anti-glare shield in position and
screw both tilt lock bolts again.
Note: The anti-glare shields are suitable for both permanent outdoor and
indoor installations.
For further information and other possibilities see www.sgmlight.com or contact your local SGM dealer.
Maintenance
SGM Vacuum Test kit
- The Vacuum Test Kit is an accessory suitable for all SGM IP-rated fixtures, made for testing the IP validity after having reassembled the fixture.
- In order to ensure the IP rating of the P-2 Series, it’s highly recommended that the fixture is always vacuum-tested after installing or swapping any part that might compromise the IP rating, e.g. swapping the front lens.
- SGM disclaims liability for any damage occasioned by non-use or inability to use the vacuum test kit after reassembling the fixture.
- SGM Uploader cable
- The SGM USB to DMX cable is an accessory used mainly to update the fixture with the latest SGM firmware. See below how to update the fixture with the latest firmware.
- Both the SGM Uploader cable and the SGM Uploader cable POI are also used for controlling the DMX values channel by channel through the Firmware Uploader Tool software (available for download at www.sgmlight.com).
- SGM Uploader cable, POI
- This cable is an accessory to upload firmware in fixtures not using XLR connectors, such as POI series. See below how to update the fixture with the latest firmware.
- Upgrading the firmware
- The firmware installed in the fixture can be identified in different ways:
- When powering on the fixture, the display shows the current installed firmware version (only standard).
- Go to MENU → INFO → FIRMWARE VERSION (only standard).
- Through RDM.
- We recommend that the fixture’s firmware is kept always up-to-date. The latest firmware version is available for download under the respective product at www.sgmlight.com.
- To update your P-10 with the latest firmware, use an SGM USB 5-Pin-XLR uploader cable, and a Windows-based computer with the
- SGM Firmware Tool software installed (available for download at www.sgmlight.com).
- Figure 26: SGM Firmware tool
Additionally, the Firmware Tool software offers a simple DMX controller, featuring 512 DMX channels for test purposes.
Cleaning
- SGM fixtures with IP65 or IP66 rating do not need any cleaning procedures inside the fixture. However, cleaning the front lens may be needed to achieve the maximum light output after exposure to dust, sand, or dirt. Exterior housing can also be cleaned to get a better look. To maintain adequate cooling, fans must be cleaned periodically.
- Whenever necessary, clean the P-10 Series using a soft cloth dampened in a solution of water and mild detergent. Do not use products that contain solvents, abrasives, or caustic agents for cleaning, as they can cause damage to both hardware, cables, and connectors.
- The level of cleaning required will vary greatly depending on the operating environment and installation. Therefore, it is recommended to do frequent check-ups during the first few weeks of operation to see how often cleaning is necessary.
Fixtures and accessories
- The P-10 Series can be used with a variety of accessories.
- Contact your local SGM dealer to get the latest pricing and news about available accessories.
- Please note : the products listed below are subject to change without notice.
Ordering information
- P-10, Std, BL ……………………………………………………………………………………………………………………………………………… P/N: 80033001
- P-10, Std, WH ………………………………………………………………………………………………………………………………………………P/N: 80033011
- P-10, Std, CU …………………………………………………………………………………………………………………………………………….. P/N: 80033021
- P-10, POI, BL …………………………………………………………………………………………………………………………………………….. P/N: 80270103
- P-10, POI, WH ……………………………………………………………………………………………………………………………………………. P/N: 80270104
- P-10, POI, CU …………………………………………………………………………………………………………………………………………….. P/N: 80270105
- P-10, 35°, POI, BL ………………………………………………………………………………………………………………………………………. P/N: 80270106
- P-10, 35°, POI, WH …………………………………………………………………………………………………………………………………….. P/N: 80270107
- P-10, 35°, POI, CU ……………………………………………………………………………………………………………………………………… P/N: 80270108
- P-10, 25°, POI, BL ………………………………………………………………………………………………………………………………………..P/N: 80270110
- P-10, 25°, POI, WH ………………………………………………………………………………………………………………………………………P/N: 80270111
- P-10, 25°, POI, CU ……………………………………………………………………………………………………………………………………….P/N: 80270112
- The P-10 Series can be ordered in any RAL color. Contact your local SGM dealer for ordering customized color housings.
P-10 Accessories
- Power cable with IP connector …………………………………………………………………………………………………………………….. P/N: 07860040
- SGM USB uploader cable …………………………………………………………………………………………………………………………….P/N: 83062011
- SGM USB uploader cable POI ……………………………………………………………………………………………………………………….P/N: 830620 67
- Omega bracket w/Q-bolt, BL / WH ………………………………………………………………………………………………. P/N: 83060602 / 83061206
- Omega bracket POI with M10 Screws, BL / WH …………………………………………………………………………….. P/N: 83060623 / 83060624
- Barndoor 4-way, P-10, BL………………………………………………………………………………………………………………………………P/N: 83061152
- Half Anti-Glare Shield, Large, BL …………………………………………………………………………………………………………………….P/N: 83061 163
- Full Anti-Glare Shield, Large, BL …………………………………………………………………………………………………………………….P/N: 83061167
- Filter frame – Medium angle, BL – P-10 series ………………………………………………………………………………………………….P/N: 83061 156
- Filter frame – Wide angle, BL – P-10 series ……………………………………………………………………………………………………..P/N: 83061157
- Filter frame – Elliptical horz wide angle, BL – P-10 series …………………………………………………………………………………..P/N: 83061158
- Filter frame – Elliptical vert wide angle, BL – P-10 series ……………………………………………………………………………………P/N: 83061159
- Flightcase for 2 pcs of P-10 incl. accessories ……………………………………………………………………………………………….. P/N: 82051504
- SGM Vacuum test-kit …………………………………………………………………………………………………………………………………… P/N: 83061 136
Support hotline
- SGM offers 24/7 technical support hotline.
- Worldwide : +45 3840 3840
- US : +1 407-242-6217
- support@sgmlight.com
Approvals and certifications
- Conforms to 2014/35/EU : Low Voltage Directive
- Conforms to 2014/30/EU: EMC Directive
- Conforms to 2011/65/EU : RoHS2 Directive
- Conforms to UL Std. 1573: UL
The information in this document is subject to change without notice. For the latest information, visit www.sgmlight.com
User Notes
- SGM Light A/S
- Sommervej 23
- 8210 Aarhus V
- Denmark
- Tel: +45 70 20 74 00
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>