Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off power before changing fixture.
- Suitable for use in damp environments at temperatures ranging from -4°F to 104°F. Not for use where directly exposed to water.
- Not intended for use with emergency fixtures.
- Not compatible with photo-electric sensors.
- Not compatible with motion sensors.
- Not compatible with third party sensors.
- Not compatible with dimmers. For more dimming information, please visit www.sunco.com.
- Not compatible with timing devices.
- All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards.
- Please review installation manual carefully before proceeding. Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.
WARNING:
Cancer & Reproductive Harm-
www.P65Warnings.ca.gov
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
Step 1
Label wires when replacing fixtures.
Step 2
Screw (AA) into junction box, leaving 1/4” exposed.
Step 3
Press for secure, audible “click.”
Step 4
Reattach diffuser & secure with aluminum base.
Installation Guide
(Junction Box Installation)
STEP 1
a. Turn off circuit breaker before installation.
b. For fixture replacement, sketch or label wires for reference.
STEP 2
a. Remove the diffuser from the lamp base.
b. Select desired color temperature and brightness.
STEP 3
a. Screw (AA) into junction box, leaving 1/4” exposed for lamp.
b. In the junction box, connect wires:
Live (black) to Live ; Neutral (white) to Neutral ; Ground (yellow/ green) to
Ground. Secure with wire nuts and tuck into the box.
STEP 4
a. Align Lamp Base holes with junction box screws.
b. Rotate Lamp Base clockwise to secure it, and tighten screws for
fixture stability.
STEP 5
a. Punch an end cap hole, remove cables from the lamp base, and connect
wires: Live (black) to Live, Neutral (white) to Neutral, Ground (yellow/green)
to Ground.
b. The wiring between the fixtures is clamped with a wire connectors to
ensure that the clamping is not loose, and then put on the heat shrink tube to
tighten.
c. Size of conduit ≤1 inch ( 1/2” 3/4” 1” )
STEP 6
a. Reattach the diffuser (cover): Align one end and gently press down.
Push the diffuser to the corner of the lamp base. Secure the diffuser with the
aluminum base.
b. Restore power by turning on the circuit breaker and test the light.
(Keyhole Installation)
STEP 1
a. Turn off circuit breaker before installation.
b. For fixture replacement, sketch or label wires for reference.
c. The mounting surface must support the fixture’s weight. Detach the
diffuser from the lamp base.
STEP 2
a. Choose your preferred color temperature and brightness.
b. Align the Lamp Base with the mounting location using the knockout
holes. Mark the 4 keyhole slots at each end of the housing.
STEP 3
DRYWALL MOUNTING (No Stud):
Drill 4 small pilot holes with a 7/32” bit (not included). Insert wall anchors
with a hammer. Partially tighten 4 wood screws, leaving a 3/8” gap between the
screw head and the mounting surface.
STEP 4
a. WALL STUP MOUNTING OPTION
Drill 4x small pilot holes with a 9/64” drill bit (not included). Install 4x
wood screws into the mounting surface, but not fully. Leave about a 3/8” gap
between the screw head and mount surface.
STEP 5
a. Take out the cables from the lamp base. Remove shrink wrap, connect
wires: Live (black) to Live, Neutral (white) to Neutral, Ground
(yellow/green).
b. Insert screws into keyhole slots, slide lamp base (a) to align screw
heads, and secure fixture to mounting surface. Use provided washer for added
vibration protection.
STEP 6
a. Reattach the diffuser, align and secure with metal base. Restore power and
test the light.
b. Turn on circuit breaker and the test light.
Product Details
Recommended Dimmers
Specifications
Voltage | 120V-277V |
---|---|
Wattage | 60W |
Power Factor | 0.7 |
Amps | 0.583Am |
CCT | 4000K/5000K/6000K |
Housing Material | PC + Steel |
Dimmable | Non-dimmable |
Average Lifetime | 50000 hrs |
Lumens | 7200LM |
Temperature | -4°F to 104°F |
CRI | 80+ |
Efficacy | 120lm/w |
Usage | Indoor |
Warranty | 7 Years |
Common Troubleshooting
Installation
Light isn’t turning on.| Double check if fixture is properly connected and
circuit breaker hasn’t been tripped.
Light unexpectedly fails.| For further assistance, reach out to customer
support.
Dimming
Light not dimming to lowest setting.| Light not dimmer compatible.
Light not dimming smoothly.| Light not dimmer compatible.
Light not compatible with dimmer switch.| Light not dimmer compatible.
Flickering
Light is flickering when turning on.| Check that fixture wiring connections
are secure
Light flickering with other lights on the same circuit.| Check that the lights
on the same circuit are not overloading the circuit.
Light flickering when turned on| Verify fixture compatibility and that it is
grounded.
Light flickering when dimmed.| Light not dimmer compatible.
Buzzing
Fixture buzzing with power outages.| Verify light is connected to surge
protector securely.
Fixture buzzing with appliances or electronic devices.| Look for nearby
interferences that can cause buzzing. Such as televisions, radios, computers,
etc.
Fixture buzzing when dimmed.| Light not dimmer compatible.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light
source. It is an important factor to consider when selecting a fixture or
bulb, as it affects the way it will illuminate an area. There are two main
types of lighting distribution angles:
A symmetric lighting distribution emits light evenly in all directions,
creating a cone-shaped pattern that provides a pool of light. This type of
lighting is ideal for general lighting and illuminating large areas. Common
applications for symmetric lighting include general area illumination,
security lighting, and perimeter lighting. Symmetric lighting is also used to
a certain degree in up-lighting.
An asymmetric lighting distribution angle, also known as beam angle, creates a
pattern that focuses light in a specific direction. This type of lighting is
ideal for task lighting as it reduces glare and light spill in other areas.
Common applications include task lighting in spaces such as landscape
settings, retail stores, museums, and much more.
It is important to note that the lighting distribution angle can also be
affected by other factors such as the reflector design of the light source,
the type of lens used, and the distance between the light source and the
surface being illuminated.
Customer Support
Warranty Policy
This product is covered by our industry leading 7 year warranty.
It gets even better – scan the QR code for 2 extra years of protection!
30 Day Return Policy
At Sunco, we value our customers and stand by the quality and performance of
our products.
If you are not completely satisfied with your purchase, we accept returns
within 30 days of your purchase date.
Customer Service
Our Los Angeles team of lighting experts is here to assist you with all
your needs! Contact us at:
Email: support@sunco.com
Call or Text: 844-334-9938
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>