Fehom JD025L-80 80 Pints Dehumidifier Most Efficient Energy Star User Manual

June 2, 2024
Fehom

Fehom-LOGO

Fehom JD025L-80 80 Pints Dehumidifier Most Efficient Energy Star

BEFORE FIRST USE

To protect the product from any internal damages, please keep the product in an upright position throughout its journey.
Please take out the product and leave it standing in the upright position for 24 HOURS before plugging it in.

FEATURES

Powerful Moisture Removal

With cutting-edge technology, the dehumidifier powerfully removes moisture from the air to reduce the room humidity level and keep the indoor air dry and comfortable.

Lightweight Portable Design

The dehumidifier is compact and lightweight. The casters at the bottom make it easy to move the machine from one room to another.

Low Temperature Operation with Automatic Defrost Function

After the compressor runs continuously for 10 minutes, start to detect the temperature of the coil. When the temperature of the coil is ≤-2°C(28.4°F) for more than 10 seconds, the compressor will stop immediately, and the fan will be forced to run with high wind. After 3 minutes, when it is detected that the coil temperature is ≥5°C(41°F) for more than 10 seconds, then exit the anti- frost, and the compressor and fan will return to normal; (if the anti-frost time is longer than 10 minutes, it will automatically exit)

During the anti-frost period, if the water is full, the fan will be turned off. After the water level is restored, the fan will resume forced high-wind operation; (if the anti-frost time is longer than 10 minutes, it will automatically exit)

Adjustable Humidistat
Allows you to set different humidity levels for different rooms.

Timer On / Off
Program the machine to turn on and off automatically.

Quiet Operation
The dehumidifier operates with a low noise level.

Energy Efficient
The power consumption of the machine is low.

SAFETY PRECAUTIONS

IMPORTANT NOTICE FOR FIRST USE:

For your safety, please read the manual carefully and keep it for future reference.

Please install and use this product according to the instructions in the manual.

  • Please unplug the power cord before cleaning or storing the machine .

  • The machine can be used indoor except for laundry rooms.

  • Do not place the machine close to heat-generating devices or flammable and
    dangerous materials.

  • Never put your fingers or other objects into the intake or discharge ducts.

  • Do not sit or stand on the machine.

  • Pour out the collected water in the tank as required.

  • Do not operate the dehumidifier in a closed area such as a closet, as it may cause a fire.

  • Do not place the machine near edible items, artwork, or scientific materials. Install the drain hose at a downhill grade to make sure that condensed water can bedrained continuously.

  • If the power cord is damaged, please contact the manufacturer or qualified person to replace it to avoid hazards.

  • The machine must be positioned so that the plug is accessible.

  • Please keep a distance of 20 cm away from the wall or other objects to ensure great air circulation.

  • The machine shall be installed in accordance with local national wire regulations.

  • The machine can not be used in public transportation.

  • This machine can be used by children aging from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack experience and knowledge if they have been given supervision or instructions of the machine in a safe way and understand the hazards involved. Children shall not play with the machine. Cleaning and user maintenance shall not be made by children without supervision.

  • Children should be supervised to ensure that they do not play with the machine.

  • Please do not operate the machine if it is obviously damaged.

Important Safety Instructions

General Safety Instructions

  • The dehumidifier is only suitable for indoor use, and is not suitable for other applications.
  • Place the machine in a flat and dry place and keep a distance of above 50cm between the machine and the surrounding objects or walls.
  • Please ensure that the power plug is intact and firmly plugged into the power outlet, and place the power cord orderly to prevent someone from being tripped or pulling out the plug.
  • Do not put any object into the air inlet and outlet of the dehumidifier. Keep the air inlet and outlet free from obstructions.
  • When drainage pipes are installed, ensure that the drainage pipes are properly connected, and are not distorted or bended. While adjusting the upper and lower wind-guide strips of the air outlet, pluck it with hands gently to avoid damaging wind-guide strips.
  • When moving the machine, make sure that it is in an upright position.
  • The machine should stay away from gasoline, flammable gas, stoves and other heat sources.
  • Don’t disassemble, overhaul and modify the machine arbitrarily, otherwise it will cause a machine malfunction or even bring harm to persons and properties. lo avoid danger, if a machine failure occurs, ask the manufacturer or professionals to repair it.
  • Do not pull the plug to turn off the machine.
  • Do not place cups or other objects on the body to prevent water or other liquids from spilling into the dehumidifier.
  • Do not use insecticide sprays or other flammable substances near the dehumidifier
  • Do not wipe or wash the dehumidifier with chemical solvents such as gasoline and alcohol. When you need to clean the dehumidifier, you must disconnect the power supply, and clean it with a half-wet soft cloth. If the machine is really dirty, scrub with a mild detergent.
  • The appliance can be used by children aged from 8 years and above and personswith reduced physical, sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and maintenance shall not be made by children without supervision.
  • If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • If the supply cord 1s damaged,it must be replaced by the manufacturer,its service agent or similarly qualified persons in order to avoid a hazard
  • The appliance shall be stored so as to prevent mechanical damage from occurring.
  • The appliance shall be installed in accordance with national wiring regulations.

Special Safety Instructions for using flammable refrigerant

  1. Transport of equipment containing flammable refrigerants

    • Compliance with the transport regulations
  2. Marking of equipment using signs

    • Compliance with local regulations
  3. Disposal of equipment using flammable refrigerants

    • Compliance with national regulations
  4. Storage of equipment/appliances

    • The storage of equipment should be in accordance with the manufacturer’s instructions.
  5. Storage of packed (unsold) equipment

    • Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
    • The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
  6. Information on servicing

    • 6-1 Checks to the area

    • Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized.

    • For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

    • 6-2 Work procedure

    • Work shall be undertaken under a controlled procedure so as to minimize the risk of flammable gas or vapour being present while the work is being performed.

    • 6-3 General work area

    • All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided.

    • The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

    • 6-4 Checking for the presence of refrigerant

    • The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician is aware of potentially flammable atmospheres.

    • Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.

    • 6-5 Presence of fire extinguisher

    • If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand.

    • Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

    • 6-6 No ignition sources

    • No person carrying out work in relation to a refrigeration system which involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.

    • All possible ignition sources including cigarette smoking should he kent!

    • sufficiently far away from the site of installation, repairing, removal and disposal, during which flammable refrigerant can possibly be released to the surrounding space.
      Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

    • 6-7 Ventilated area

    • Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.

    • A degree of ventilation shall continue during the period that the work is carried out.

    • The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

    • 6-8 Checks to the refrigeration equipment

    • Where electrical components are being changed, they shall be fit for the purpose and to the correct specification.

    • At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance.

    • The following checks shall be applied to installations using flammable refrigerants

    • The charge size is in accordance with the room size within which the refrigerant-containing parts are installed;

    • The ventilation machinery and outlets are operating adequately and are not obstructed;

    • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;

    • Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;

    • Refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance that may corrode refrigerant-containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.

    • 6-9 Checks to electrical devices

    • Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures.

    • If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.

    • If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.

    • This shall be reported to the owner of the equipment so all parties are advised.

    • Initial safety checks shall include:

    • That capacitors are discharged: this shall be done in a safe manner to avoid the possibility of sparking;

    • That there no live electrical components and wiring are exposed while charging, recovering or purging the system;

    • That there is continuity of earth bonding.

  7. Repairs to sealed components

    • During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc.
    • Ifit is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
    • Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.
    • This shall include damage to cables, an excessive number of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, ete.
    • Ensure that the apparatus is mounted securely.
    • Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres.
    • Replacement parts shall be in accordance with the manufacturer’s specifications.
    • NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
  8. Repair to intrinsically safe components

    • ensuring thy are permanent ex inductiversisit volage and therein permithout for the equipment in use.
    • Intrinsically safe components are the only types that can be worked on while living in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating.
    • Replace components only with parts specified by the manufacturer.
    • Other parts may result in the ignition of refrigerant in the atmosphere from a leak.
  9. Cabling

    • Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects.
    • The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
  10. Detection of flammable refrigerants

    • Ur or detections tiger potential sources of ignition be used in the searching
    • A halide torch (or any other detector using a naked flame) shall not be used.
  11. Leak detection methods

    • The following leak detection methods are deemed acceptable for systems containing flammable refrigerants:
    • Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate or may need re-calibration. (Detection equipment shall be calibrated in a refrigerant-free area.)
    • Ensure that the detector is not a potential source of ignition and is suitable for the refrigerant used.
    • Leak detection equipment shall be set at a percentage of the LFL of the refrigerant and shall be calibrated to the refrigerant employed and the appropriate percentage of gas (25% maximum) is confirmed.
    • If the refrigerant is flammable the dehumidifier equipment shall have red, Pantone® Matching System (PMS) #185 marked service ports, pipes, hoses, and other devices through which the refrigerant is serviced. This colour shall be present at all service ports and where service puncturing or otherwise creating an opening from the refrigerant circuit to the atmosphere might be expected (e.g., process tubes). The color mark shall extend at least 25 mm (1 inch) from the refrigerant servicing point and shall be replaced if removed

WARNING

Caution rick of fire

  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

The appliance shall be stored in a room without continuously operating the ignition electric heater). Do not pierce or burn.

  • Be aware that refrigerants may not contain an odor.

Explanation of symbol displayed on the unit.

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG3

SPECIFICATIONS

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG19

  • The dehumidification capacity is rated at a room temperature of 18.3°C(64.94°F) with a relative humidity of 60%RH.
  • If specifications are changed in the future, the product nameplate will reflect the new specifications.
  • The working temperature range of this machine is between 7°C(44.6°F) and 32°C(89.6°F).
  • If the room temperature is not within this range, the unit will not operate normally.  GWP value of R32

WARNING

This product can expose you to chemicals including Styrene and its compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, please visit www.P65Warning.ca.gov.

PRODUCT DRAWINGS

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG4

  1. Control panel
  2. Handle
  3. Water tank
  4. Power cord
  5. Seal cover
  6. Air outlet
  7. Wind deflector
  8. Air inlet grille
  9. Outfall
  10. Buckle
  11. Caster

OPERATION INSTRUCTIONS

  • Control Panel

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG5

Humidity Level & Timer Display 88
The indicator has 3 functions:

  1. When the machine is powered on, it will indicate the current room humidity.
  2. When you set the humidity, it will indicate the humidity that you have set.
  3. When you program the timer, it will show the timing duration.
  4. When the environment humidity is lower than 25%RH, it will show “25”.
  5. When the environment humidity is higher than 95%RH, it will show “95”

Operating Instructions

When the machine is powered on for the first time, it will buzz the power sound before entering into the standby status.

Turn On/Off:
Press ” ” to start the machine when it is powered off. Press” ” to turn off it when the machine is operating.

” Humidity Setting: Press the “ ” button to enter set the humidity level, you can press ” + • “or” — ”
to adjust the humidity from 30%RH to 80%RH in 5% increment. The LED display will flash when you adjust the humidity. The default humidity level is 40%RH.

” Fan Speed Setting:
Press ” ” to switch the fan speed between low and high level. The corresponding fan speed light will turn on.

Swing Setting:

When the machine is operating, press ” blade. ” to start or stop the swing of the air outlet

‘Timer Setting:

In the standby state, press “ ” button to set a timer to automatically start the machine. The LED display will show the time. You can press ” + “or” — ” button to adjust the timer from 01 to 24 hours.
When the machine is operating, press “
“to set a timer to automatically shut down the machine. The LED display will show the time, You can press ” + – “or” —
button to adjust the timer from 01 to 24 hours.
When the dehumidifier is turned on/ off by the user’s operations or full tank alarm, the timing function may become invalid.

DRAINAGE

MANUAL DRAINAGE

Emptying the Water Tank
When the water tank is full, the tank full indicator light “ ****  ” will turn on, and the dehumidifier will stop automatically. The buzzer will beep 15 times to remind you to empty the water tank.

  1. Gently press the sides of the tank with both your hands and pull the tank out.
  2. Pour out the collected water.
  3. Install the water tank steadily into the machine.

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG13,...,...,.,..,

NOTE

  1. Do not remove the float from the water •Ara tank. The full tank sensor will no longer be able to detect the water level correctly without the float and water may leak from the tank.
  2. If the tank is dirty, please wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated dust cloths, gasoline, benzene, thinner, or other solvents, as these may scratch and damage the tank and cause water leakage.
  3. When replacing the tank, please press the tank firmly into place with your both hands. If the tank is not positioned properly, the “ TANK FULL ” sensor will be activated, and the dehumidifier will not operate.

CONTINUOUS DRAINAGE

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG14

  1. Unscrew the outlet cover on the back of the machine.
  2. Insert the drain hose (included) and make sure the hose is secure so there are no leaks. Then the dehumidifier will continuously drain water.

Warnings:

Condensed water will dow into the water those. IF the blockage occurs, the Please do not bend the drain hose. Make sure that the height of the drain hose is lower than the drain port.
The drain hose must be firmly connected to the drain port.

Cleaning the Dehumidifier

Cleaning the Body

Wipe it with a soft damp cloth.

Cleaning the Air Filter

  1. Open the inlet grill and wash it with water.
  2. Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is exceptionally dirty, please wash it with warm water and a mild cleanser and dry thoroughly.
  3. Insert the filter into the grill smoothly.

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG15 Fehom-JD025L-80-80
-Pints-Dehumidifier-Most-Efficient-Energy-Star-FIG16

Storing the Dehumidifier

When the unit is not used for a long period of time or you want to store it. please notice the following steps:

  1. Empty any water left in the tank.
  2. Put the power supply cord away and wrap it around the hook on the back of the unit.
  3. Clean the air filter.
  4. Place it in a cool and dry place.

Clearance

Keep the minimum clearance at 18 inches around the dehumidifier when it is operating as shown in the following drawing.

Clearance

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG17

Keep the minimum clearance at 18 inches around the dehumidifier when it is operating as shown in the following drawing.

TROUBLESHOOTING

The following list contains some abnormal conditions that are not faults caused by manufacturing processes or material defects.

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG20

WARRANTY & CONTACT US

Warranty

Fehom offers a 12-month warranty to all of our products together with the original proof of purchase when a defect occured, including those newly purchased and unused, from Fehom or through an authorized reseller, wholly or substantially, or as a result of faulty manufacturing parts, or workmanship during the Warranty Period.

The warranty does not apply if the damage is caused by other factors, including but without limited of:

  • (a) Normal wear and tear;
  • (b) Abuse, mishandling, accident or failure to follow operating instructions;
  • (c) Exposure to liquid or infiltration of foreign particles;
  • (d) Servicing or modification of the product other than by Fehom.

There are our general terms for the warranty service, but we always encourage our customers to contact us if any issues, regardless of warranty terms.
If you are experiencing an issue with Fehom products, you can reach out to us at support@fehom.com, we will dedicate our efforts to resolve it for you.

Extend Your Warranty by 1 Year

Register your product at www.fehom.com to extend your 1-year warranty by an additional year.

Please fill out all required fields and include your Order ID, Date of Purchase if applicable.

Customer Support

If you have any questions or concerns about our product, please feel free to contact our expert support team. Fehom customer service is ready to help.

Fehom Office

Support Hours

24 Hours available

  • lease have vour Order Number ready before contacting customer support.

For FAQs and more information please visit:

Fehom-JD025L-80-80-Pints-Dehumidifier-Most-Efficient-Energy-Star-
FIG18

(Scan the QR Code for Live Chat)

We are expecting to see our products fulfill your life and hear your voice.

Your satisfaction means a lot to us.

Please tag us if you share a snap on your social media.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals