WM SYSTEMS WM-E3S 4G Modem Configuration
WM-E3S 4G CI® modem WM-E3S 4G CI R® modem
Installation Guide and Modem Configuration
Document specifications
This documentation was made for the installation and configuration of the WM- E3S 4G CI® (Customer Interface version) modem and the WM-E3S 4G CI R® (Customer Interface and relay output version) modem.
Document Version: | REV 1.5.1 |
---|---|
Hardware Type/Version: | WM-E3S 4G CI ® , |
WM-E3S 4G CI R ®
modem for electricity metering
Hardware Version:| V 4.41 + CI board
Firmware Version:| V 2.3.10
WM-E Term ® config. software version:| V 1.3.78
Pages:| 24
Status:| Final
Created:| 15-11-2016
Last Modified:| 20-01-2022
Introduction
The WM-E3S 4G CI® is an integrated modem, which is suitable for remote reading
of electricity meters remotely, on the 4G LTE-based cellular network. The
communication module is a part of the Smart Metering concept.
This modem was especially developed for Elster® AS220, AS230, AS300, AS1440,
AS3000, AS3500 electricity meters, and can be connected to the meter by
sliding into the meters’ communication module slot and can be sealed.
Thus, the modem presents a compact solution, the dimensions of the meter will
not change if a modem if fitted or not. This solution offers the possibility
of future upgrade of the electricity meter with a communication module and is
ideal for installations where there is restricted assembling space. The modem
is powered internally by 230V AC power through the meter’s integrated mains
connector.
The WM-E3S 4G® is modem is suitable for reading the meter’s actual and stored
consumption values, access the recorded event log, read the load profile data,
and read or modify the parameter set of the meter – remotely.
The modem can be accessed remotely through the cellular network (by the Telit®
module) and it is able to send data on the Internet by using an APN.
It has 2G fallback features, therefore in case of outage/inaccessibility of
the 4G network it is communicating further on the 2G network.
You can save money by using our modem, because there is no further need of
manual readout of the meter systems.
The Customer Interface (CI) version receives data from the meter in the
scheduled intervals, therefore can readout the meter registers over the
parameters.
All over these, the „R” version (WM-E3S 4G CI R® modem) has relay output,
therefore the it can switch the meter to change the tarrif mode through its
output – due to the 1-4 configures Tariff-mode settings.
The modem can be used with push data transmission method, thus the modem can initiate the communication with the AMR centre periodically at a pre- programmed time interval or triggered by an alarm (power outage, cover removal, reverse run, etc.)
The device can be configured through the serial port, but can be performed through TCP connection remotely.
Connections
Interface connectors, internal connections (mainboard)
- Mains connector
- Push button
- Data connector (to the meter)
- SIM card socket (push-insert)
- Status LEDs
- SMA antenna connector
- U.FL antenna connector
- Telit LTE module
- Rechargeable battery (for spare purposes)
- Power adapter unit
- RJ12 interface connector (6P6C)
- Internal data connector (for relay board „R” version)
- Relay output (on expansion board) – optional
Interface connectors, internal connection (expansion board)
Assembled modem (mainboard + expansion board)
We deliver assembled product as it is show in the picture.
Inserting a SIM card
Insert an activated SIM card into the push-push SIM card slot (4). The SIM
card is replaceable by pushing the inserted SIM card – if it is necessary.
Connecting the modem the AS3000, A3500 meter
Remove the Elster® AS3000, AS3500 meter’s communication module plastic case by
releasing the screw from the top middle part of the housing.
Inside the communication unit’s case mount the SMA-M antenna interface connector (6) on the housing (fix it with the SMA connector’s screw).
Snap the modem unit (mainboard + expansion board) into the communication module terminal’s plastic enclosure by sliding into, through the guiding rails of the case. Insert the modem into the right orientation into the slot. Check the 12-pin data connector (3) position – according the next picture.
Push the modem into the terminal enclosure, until you’ll hear a click sound.
The interface connector (3) is close to the SMA antenna connector (6) (right
top side on the picture).
At the center of the modem you will found two plastic hooks, which helps you
at the fixation into the enclosure.
(If you want to remove the modem board, push these hooks carefully, and you
can free to remove the communication module from the terminal case.)
Now we can connect the communication module to the meter by sliding the modem
into the meter enclosure.
The communication interface (3) and the mains connectors (1) must be connected
to the connector pairs from the meter housing.
(Check the 12-pins data connector and the power connector (2-pins) position in
the picture. You will find the same connectors’ opposite part at the bottom
meter side, which you have to connect.
The meter’s terminal module housing upper right edge is a rounded as a sign of
the perfect slide fit the adaptation to the meter.
After assembling, attaching the modem terminal unit and turning on the meter, the modem will be immediately powered on, and its operation is confirmed by the LED signals.
Connecting the modem to the AS220, AS230, AS300 meter
Disassemble the Elster® AS220, AS230, AS300 meter’s communication module
plastic case. Release the top screw at the middle and take off the upper modem
unit case.
The modem can be inserted into the transparent plastic enclosure of the
communication unit.
Inside the communication module’s transparent plastic case, mount the SMA-M antenna to the antenna connector (6) on the housing (fix it with the SMA connector screw).
The communication unit now is ready to be attached to the meter by fixing it on the meter housing.
The 12 pins communication interface (3) and the mains connector (1) now plugs
into the meter.
After assembly and turning the meter on the communication module is ready for
operation. The LED signals will sign the operation status of the communication
module.
Antenna connection
For proper operation of the communication module it is necessary to have
appropriate signal strength.
In places where the signal strength is strong it is possible to use internal
antenna, for areas with poor reception mount an external antenna (50 Ohm SMA-M
connected) to the antenna connector (6) of the device, which you can place
inside even inside the meter enclusre (under the plastic housing).
using the RJ12 connection
Connect the proper cable to the modem’s RJ12 communication interface (11). The
listed registers can be readout on the cable (see Chapter 4).
The data is always active on the P1 interface, furthermore, you can readout
other registers from the meters.
The RJ12 connection pinout can be seen in the following table.
The Pin nr. 2 inactvice in case of the relay output version modem!
Relay connection
You can found the relay output (13)on the modem’s optional expansion. Then, by
using the Customer Interface, the client can receive data in cyclic intervals
from the meter, which is switching the operation by the current tarrif
settings – due to the modem’s relay output switching.
Modem Installation Guide
The WM-E3S 4G CI® communication module unit can be configured by the a WM-E Term® v1.3.19T or newer version or the DM Set® / AlphaSet® software which is also suitable for setup the electricity meter through a serial connection. The WM-E Term® tool is suitable over the communication settings to readout the P1 Customer interface registers and to perform Tariff mode settings. You can found a document about the application tool’s settings on our website. Here we show the DM-Set® software settings, which is used by the utility companies. Follow the next steps for configuring the CM to the meter.
Connection
- The DM Set® software must be installed to a Microsoft Windows® capable installed PC computer.
- Connect properly the optical head to the meter and to the USB port of the computer.
- Configure the modem through the optical head.
- Start the DM Set® application for the configuration (version 2.14 or newer is necessary).
- After launching the application, choose the Extras menu and Set modem series option.
- Then choose AMXXX option then click on the OK.
- Choose Extras menu and Options, then choose the proper serial port which is used for the connectivity of the optical head. Let’s choose the 8N1 data format and 115 200 baud speed rate for the data transfer.
- When you are configuring the modem first time, you can read out the version information only. Load the sample config file provided (go to step 9.), or request it from your supplier. IF YOU HAVE ALREADY LOADED A VALID CONFIGURATION FILE TO THE MODEM, You can use the Read Settings for readout the parameters of the meter (then edit and save the parameter settings with the Modify / Modem settings).
- Or it’s also possible to open a pre-defined configuration file with the Open File menu (after opening the file you can edit the configuration)
- Choose the Modify / Modem Settings option from the menu and give the APN server name to configure the access point name for the secure logon. (Then the modem will be communicating on the transparent data port number 9000, by default.)
- GPRS Always ON must be checked on.
- You have to fill the password regarding the SIM Card settings (get information from Your Mobile Operator)
- In case of parameter modification after the changes. You have to save the changed parameter values into the configuration file by selecting the File / Save menu.
- After the configuration the modem able to connect to the GPRS network.
- The modem will be assessable through the meter.
Testing the readout of the meter
The readout and connection can be tested with AlphaSet® application. Let’s
AlphaSet Reading and Configuration Tool Instruction Manual documentation.
“alphaset_user_manual_GBR.doc”)
Status LED signals
LED 1 flashing faster if registered on the 3G wireless network
Presence of LED 4, 5 is optional.
Push operation method
The complete readout and data sending mechanism to the centre and the other
direction for the configuration and maintenance tasks can be realized on the
defined paths.
The modem is not operate continously on the GPRS network. Therefore, there is an another option and meter data sending mode to initiate a remote readout automatically in the pre-defined intervals. Anyway, it is also possible to start the data sending in case of different events (e.g. removal of meter cover, incoming SMS message from the centre). In this situation the modem is connected to the mobile data network only during the time of the data transmission. The devices needs to be connected to GSM network and ready to connect to GPRS, but without active IP connection.
Features:
- Data Push – starting at predefined times
- The Data Push method triggers FTP file upload, plain text or encrypted.
- The unique filename and the file is generated automatically.
- The file is always has two parts, first the standard register reading, then the event log from last 31 days. (the period may extended automatically if the date of the event is earlier)
- The readings shown as standard IEC format, including some ASCII control characters like STX ETX, etc. also.
- The ftp is set to passive mode.
- Alarm Push – starting when new event can be read from meter
- Alarm Push method triggers TCP sending of a DLMS WPDU contains the IP address, listening port number for transparent service, and the meter ID.
- Triggering with SMS
- GPRS connection can be activated remotely with a defined SMS from any call number.
- The SMS text must be left empty.
- After the SMS received, the modem will connect to IP network, and will be accessible as a IP server for a time period defined in the config file.
- Example config file will be provided with a 30 minute setting.
Configuration of the push operation mode Configuration can be loaded with DM- Set, but there is no dedicated menu item for these settings. The configuration file must be edited manually. The following DM-Set configuration file items are necessary to configure this mode.
Data Push setting (using DMSet):
- GPRS always ON: unchecked
- ping IP-address host: host, user, password: ftp://username:password@host/path using IRA(ITU T.50) character set
Some parameters cannot be set ont he DMSet GUI, these must be defined by direct editing the config file in a text editor.
Config file keywords:
-
smp.always_on = 0
-
smp.connect_on_timer = 1
-
conn.ping_host = ftp://username:password@host/path
Example: ftp://device001:pwd001@server.com/upload
There can be defined a port number in the ftp upload URL. If the ftp port other than 21, eg. 1021 the port number must be defined.
Example: ftp://username:password@host:1021/path ftp://device001:pwd001@server.com:1021/upload -
smp.connect_interval = 28800
Connect interval counted in seconds. -
smp.connect_start = YYYYMMDDWWHHmmSS
Y = Years, M = Months, D = Days, W = Day of week, where 01 is Monday and 07
Sunday.
H = Hours, m = Minutes, S = Seconds, wildcards FF are allowed.
At the datetime (connet_start) the wildcard=FF, upcase only!
For example: smp.connect_start = FFFFFFFFFFFF0000 which means send once in every hour.
When the time is between 01:00:00 AM to 02:00:00 AM UTC, the scheduling maybe skipped on the start of the daylight savings, and run twice at the end.
-
csd.password = <max. 16 characters>
-
conn.apn_name = wm2m
Where apn name must be maximal 50 char long. -
conn.apn_user =
-
conn.apn_pass =
Where apn password must be maximal 30 char long. -
smp.connect_interval in seconds, max 0xFFFFFFFF Meter date format setting must be set in config file for proper operation: emeter.date_format = YYMMDD or emeter.date_format = DD-MM-YY
for example.
Encryption:
- The file can be encripted with AES-128 CBC method.
- The 128-bit key must be added to the config file.
- If the parameter is empty or the length is wrong, no encryption will be used.
- dlms.lls_secret = 00112233445566778899AABBCCDDEEFF
Triggering with SMS:
- trigger: SMS triggered (Empty SMS)
The SMS length must be 0. The encoding can be 7-bit or 8-bit.
The device will be registered to IP network for a predefined time, if the GPRS always on setting is unchecked (smp.always_on = 0) Setting of time period:
Config file keywords:
- smp.disconnect_delay = 1800
Above an example can be found, where the 1800 seconds value means that in 30 minutes online time.
Event Push settings:
The smp.disconnect_delay setting also applies to Event trigger.
The device will remain online for this time after sending the event
notification.
Config file keywords:
-
ei_client.addr =
-
ei_client.port =
example: -
ei_client.addr = 192.168.0.1
-
ei_client.port = 4000
In these examples, the IP address is 192.168.0.1 and the port number is 4000.
You can change these values with the required values.
The APN name, user and password parameters are also required for push mode operation.
The device will connect to the defined TCP port.
Event Push data format: DLMS WPDU contains the IP address, listening port number for transparent service, and the meter ID.
TCP data, binary, 29-byte:
0001000100010015FF0203060ACAB60F12232809083035323035383431
Structure:
DLMS WPDU HEADER, 8-byte
- Version = 1
- srcPort = 1
- dstPort = 1
- Payload Length = 21
AXDR encoded data packet:
-
-
-
IP address -
port number, that the device listening on -
meter ID
-
When You’ll save the DM-Set configuration file, please consider that the
filename must be used the following naming convention:
IMEINumber_MeterCode_SN
Example: 123456789012345_ELS5_SN12345678_20140101_010000_1234.TXT
All strings in parameters must be fit to the IRA character set.
Reference:
http://en.wikipedia.org/wiki/ITU_T.50
If You’re using a 3G capable version of modem hardware it is highly
recommended to set the modem to 2G communication mode for reliable CSD
connection.
When further information is necessary related on the implementation, this can
be requested from our technical support.
P1 registers
Always active data and registers on the P1 interface
Choosable/selectable registers on the P1 interface
Support
If you have a technical question regarding the usage You can find us on the
following contact possibilities:
Email: support@m2mserver.com
Phone: +36 20 333-1111
Support
The product has a identification void which has important product-related
information for the support line.
Warning! Damaging or removing the void sticker means the loss of product
guarantee.
Online product support available here: https://www.m2mserver.com/en/support/
Product Support
The documents and information related on the product are available here.
https://www.m2mserver.com/en/product/wm-e3s/
Legal notice
©2022. WM Systems LLC.
The text of and illustrations presented in this document are under copyright.
Copying, usage, replication or publication of the original document or its’
parts are possible with the agreement and permission of the WM Systems LLC.
only.
The figures in this document are illustrations, those can be different from
the real appearance.
The WM Systems LLC doesn’t take any responsibility for text inaccuracy in this
document.
The presented information can be changed without any notice.
The printed information in this document are informative only. For further
details contact us.
Warning
Any fault or upcoming error during the software upload/refresh can lead to the
device breakdown. When this situation happens call our specialists.
References