Product Information

Model: E62-M3 –
Power: Mid
Power – Radio Type: 2T2R
Digital Radio – Output Power: Up to 40dBm
Frequency Band: C-Band
Compliance: FCC Part 15, FCC radiation exposure limits
Manufacturer: Corning Optical Communications

Product Usage Instructions

Installation:

  • Ensure that the socket-outlet is easily accessible for power connection.
  • Install the equipment with a minimum distance of 72cm between the radiator and your body to comply with FCC radiation exposure limits.

Overview:

  • The Everon E62-M3 is a digital transport platform designed for C-band operation in cellular technologies using fiber optic cable and the CPRI protocol.
  • The power amplifier technology utilizes Digital Pre-Distortion, resulting in improved power consumption compared to analog technology.
  • This platform is suitable for multi-operator multiband deployments of cellular services.

Key Features :

  • 2T2R Digital Radio: Supports Full C-band operation with a Single Fiber Link.
  • Output Power: Can reach up to 40dBm.
  • External Alarm Support: Supports external alarm systems.
  • 5GNR Compliant: Complies with 5G New Radio standards.

System Elements:

  • A3 Access Unit: Primary access unit for the system.
  • E3-O Optical Expansion Unit: Optical expansion unit.
  • M3 Mid Power Remote Unit: Mid power remote unit.

Technical Specifications:

  • Maximum RF Bands per Access Unit: 4
  • Maximum RF Bands per Remote Unit: 2 –
  • Maximum Access Units per System: 3 (1 x Primary A3 / 2 x Secondary A3)
  • Maximum E3s per Primary A3: 8
  • Maximum M3RUs per E3: 14
  • Maximum Cascaded Level: 6
  • Maximum IBW Band Selective Mode: 200MHz (can be increased to 280M via firmware upgrade)
  • Channel Selective Mode: 100MHz, with 1MHz step
  • Fiber Transmission Capacity: Supports LTE: 5/10/15/20 MHz and NR: 5/10/15/20/30/40/50/60/70/80/90/100 MHz
  • Filter Bandwidth: 25M
  • Basic Units Occupied: 48
  • M3RU DSP Capacity: 25
  • Filter Bandwidth DSP Units occupied: 25
  • Maximum Carriers Supported per Band: 25
  • System Delay Adjustment: Available
  • System Delay (A3+E3+M3): Varies based on configuration
  • VSWR (Voltage Standing Wave Ratio): Supported

Supported Configurations:

  • Configuration: CH1
  • Maximum RF Bands per Access Unit: 4
  • Maximum RF Bands per Remote Unit: 2
  • Maximum Access Units per System: 3 (1 x Primary A3 / 2 x Secondary A3)
  • Maximum E3s per Primary A3: 8
  • Maximum M3RUs per E3: 14
  • Maximum Cascaded Level: 6 Please refer to the complete user manual for further details and instructions on configuring and operating the E62-M3 digital transport platform.

Revision History

Revision Number Revision Date Summary of Changes Author
1.0.0    
     
     
     
     
     

Copyright © 2023 Sunwave All rights reserved.
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Sunwave. All copyright, confidential information, patents, design rights and all other intellectual property rights of whatsoever nature contained herein are and shall remain the sole and exclusive property of Sunwave. The information furnished herein is believed to be accurate and reliable.However, no responsibility is assumed by Sunwave for its use, or for any infringements of patents or other rights of third parties resulting from its use. The Sunwave and CrossFire names and logos are trademarks or registered trademarks of Sunwave. All other trademarks are the property of their respective owners.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  • (1) This device may not cause harmful interference, and
  • (2) This device must accept any interference received, including interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 72cm between the radiator & your body.
The socket-outlet shall be easily accessible.

Overview

Everon E62-M3 is a digital transport platform dedicated for C-band operation supporting cellular technologies on fiber optic cable using the CPRI protocol. The power amplifier technology adopts Digital Pre-Distortion, allowing for a significant improvement in power consumption compared with analogue technology. This platform is ideal for multi-operator multi-band deployments of cellular services.

Key Features

  • 2T2R Digital Radio
  • Support Full C-band SISO
  • Single Fiber Link
  • Up to 40dBm Output
  • Power Supports External Alarm
  • 5GNR Complian

System Elements

E62-M3-MiDi-Power-2T2R-Digital-Radio-FIG-1

Block Diagram

E62-M3-MiDi-Power-2T2R-Digital-Radio-
FIG-2

Technical Specifications

System|  |  |  |
---|---|---|---|---
Maximum RF Bands per Access Unit| 4|  |  |
Maximum RF Bands per Remote Unit| 2|  |  |
Maximum Access Units per System| 3 (1 x Primary A3 / 2 x Secondary A3)|  |
Maximum E3s per Primary A3| 8|  |  |
Maximum M3RUs per E3| 14|  |  |
Maximum Cascaded Level| 6|  |  |
Maximum IBW| 200MHz, (280M by firmware upgrade)|  |
Band Selective Mode| ≤100MHz, @1MHz step|  |
Channel Selective Mode| LTE: 5/10/15/20 MHz

NR: 5/10/15/20/30/40/50/60/70/80/90/100 MHz

|
Fiber transmission Capacity| 48 Basic Units|  |  |
Filter Bandwidth| ≤25M| 25<BW≤50M| 50<BW≤75M| 75<BW≤100M
Basic Units Occupied| 1| 2| 3| 4
M3RU DSP Capacity| 12 DSP Units per Band|  |
Filter Bandwidth| ≤25M| 25<BW≤50M| 50<BW≤75M| 75<BW≤100M
DSP Units occupied| 1| 2| 4| 4
Maximum Carriers Supported per Band| 4

8 (Full C-band Mode)

|  |  |
System Delay Adjustment| Up to 80.00µs|  |  |
System Delay (A3+E3+M3)| 12µS|  |  |
VSWR| <1.6|  |  |
Supported Configurations

Configuration| CH1| CH2
Full C-Band1| 3450-3800M| 3700-3980M
---|---|---
Reverse Path (Uplink)|
---|---
Output Power per Band| -10 ± 2dBm for C-Band (-13dBm for each sub-band)
Maximum Gain| 37 ± 3dB for C-Band
Maximum Input Power| -35dBm
Manual Gain Control| 35dB @ 1dB/step (AU: 20dB, M3: 15dB)
Noise Figure| 6dB@max Gain
IIP3| -22dBm
Interfaces|
---|---
M3 Antenna Interface| 4.3-10 Female
M3 RF coupling port| QMA Female
A3 RF Interface| QMA Female
Optical Connector Type| SFP28, Standard LC
Optical Transmission Rate| 24.33024 Gb/s
Optical Fibre Length| 10km
Physical Alarms| RJ45 (2x in, 2x out)
Maintenance Interface| Ethernet RJ45
Electrical|
---|---
Complies with| 3GPP TS36.106 | 3GPP TS25.106
EMC| EN 301489-1 / -50, FCC 47 CFR 1.1307(b), FCC 47 CFR 1.310
Safety| EN 62368-1
Maximum Power Consumption (A3/E3/M3)| 60W / 40W / 200W
Power Supply| 100-240V AC, 50/60Hz | 48VDC ± 20%
Environmental|
---|---
Mean Time Between Failure (MTBF)| >220,000 hours
Operating Temperature (A3/E3)| -10°C to +50°C / 14°F to +122°F
Operating Temperature (M3)| -40°C to +55°C / -40°F to +131°F
Humidity| 0% to 90% (Non-Condensing)
Cooling| Convection
Installation| A3/E3: Wall or 19” Rack | M3: Wall, Pole, 19” Rack
Mechanical|
---|---
A3 (Width / Height / Depth / Weight) With package| 440mm / 88mm / 329mm / 6.5kg, 17.32in / 3.46in / 12.95in / 14.33lb 555mm / 140mm / 535mm / 8.0kg, 21.85in / 7.09in / 21.06in / 17.64lb
E3 (Width / Height / Depth / Weight)

With package

| 440mm / 44mm / 220mm / 5.0kg, 17.32in / 1.73in / 8.66in / 11.02lb

555mm / 140mm / 370mm / 7.0kg, 21.85in / 7.09in / 14.57in / 15.43lb

M3 (Width / Height / Depth / Weight) With package| 330mm / 126mm / 250mm / 14.0kg, 13.00in / 4.96in / 9.84in / 30.86lb