EUROPLAST EE100 Bathroom Extractor Suction Fan Instruction Manual

June 2, 2024
EUROPLAST

EUROPLAST EE100 Bathroom Extractor Suction Fan

EUROPLAST-EE100-Bathroom-Extractor-Suction-Fan

Specifications

Model EE100 EE120 EE125 EE150
Voltage (V) 220 – 240
Frequency (Hz) 50
Power (W) 15 16 16 20
Productivity (m³/h) 100 145 150 200
Sound Level at 3m, Lp dB(A) 32 34 36 40
Environmental Impact Protection IPX4
Rotations/min 2550 2400 2360 2100
Ambient Temperature +5°C – +40°C
Weight (kg) 0.37 0.44 0.44 0.56

Product Information

The Model eextra series EE ventilator is designed for residential and commercial use. It comes in various sizes including EE100, EE120, EE125, and EE150 with different dimensions and specifications.

Dimensions (mm):

| A| B| C| D| E
---|---|---|---|---|---
EE100| 140| 140| 80| 99| 16
EE120| 165| 165| 80| 119| 16
EE125| 165| 165| 80| 124| 16
EE150| 190| 190| 80| 149| 16

Product Usage Instructions

Installation and Maintenance:

  1. Before installing the ventilator, disconnect the power supply from the electrical network to which you plan to connect the ventilator.
  2. If the ventilator is directly connected to the electrical network, ensure that it is equipped with a switch that safely interrupts the power supply wires.

Maintenance Tips
Regularly clean the ventilator blades to ensure optimal performance.

Installation Diagrams

Zm. 1a:

 Front view of the ventilator with an arrow indicating the direction of air flow.

Zm. 1b:

 Cross-sectional view of the ventilator installed in a window, with arrows showing the opening mechanism.

Zm. 2:

 Exploded view of the ventilator showcasing the removable front cover and the main body.

Zm. 3:

 Wiring diagram for a standard switch connection with phase (L), neutral (N), and switch (S) labeled.

Zm. 4:

 Wiring diagram indicating the connection with a timer function.

Zm. 5:

 Wiring diagram showing the connection with a humidity sensor switch.

Zm. 6:

 Control panel of the ventilator with timer settings ranging from 1 minute to 30 minutes.

Zm. 7:

 Control panel with humidity settings, indicating adjustable levels from ~60% RH to ~90% RH.

Warnings

  • Before using or installing the ventilator, carefully read the instructions!
  • During unboxing, ensure the ventilator has no visible damage.
  • Before installation, check that the electrical grid’s voltage (V) and frequency (Hz) match the nominal indices inscribed on a plate inside the ventilator.
  • When connecting the ventilator, it’s important to respect the polarity (see Installation and service).
  • This device should not be used by children under 8 years old, as well as by individuals with physical or mental disabilities, unless they have read the instructions and understand the safety rules for using this product. It is prohibited for children to perform maintenance or cleaning of the device without adult supervision.

Installation and Maintenance

  • Before installing the ventilator, disconnect the power supply to which you plan to connect the ventilator.
  • If the ventilator is connected directly to the electrical grid, the latter must be equipped with a switch that ensures a safe interruption of the power supply wires.
Additional Features

Switch and Cable WP

 The ventilator with a switch and cable is connected to the electrical outlet. The ventilator is turned on using the power button on the base or the lower part of the ventilator.

Timer T

 The ventilator is equipped with a timer that continues to operate for a predetermined period after being turned off.

Timer, Cable, and Switch TWP

 The ventilator with a timer, cable, and switch is connected to a changeover switch. It disconnects after a set time interval. For setting the timer, refer to Timer T.

Humidity Sensor HT

 The ventilator is equipped with a humidity sensor that can regulate the level of humidity within a room. The ventilator automatically turns on when the humidity in the room reaches a certain level.

12V Motor – 12

 The 12V motor ventilator is intended to be installed with a 12V power supply. Caution is advised if the control unit is not connected to the electrical grid.

Warranty

The manufacturer’s warranty is valid for 24 months. In the event of damage, contact the seller.

The warranty service will not be carried out in the following cases:

  1. If mechanical or other types of damage to the product are detected;
  2. In case of mechanical defects or other types caused by the product owner’s fault or due to misuse;
  3. If defects are caused by incorrect installation or connection;
  4. If defects are due to non-compliance with the instructions in the manual.

The warranty does not cover natural wear and tear.

Frequently Asked Questions (FAQ)

What should I do if the ventilator does not start?

Check the power supply and ensure that the voltage and frequency match the specifications indicated on the ventilator.

What should be checked before the ventilator's installation?

Ensure that the electrical grid's voltage and frequency match the ventilator's specifications and that the device has no visible damage.

Can the ventilator be installed by the user?

Installation should be performed by a qualified electrician, and the power supply must be disconnected before installation.

Are there any special considerations for using the ventilator with children?

The device should not be used by children under 8 or by individuals with disabilities without proper supervision and understanding of the instructions.

How can the humidity sensor be regulated?

What is covered under the warranty?

The warranty covers defects not caused by improper use or installation, and it lasts for 24 months from the date of purchase.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals