EUROPLAST EE100 eextra Series EE Exhaust Fan Instruction Manual

June 10, 2024
EUROPLAST

EUROPLAST EE100 eextra Series EE Exhaust Fan

Product Information

The product is a ventilator with the model name eextra and series name EE. It is manufactured by Europlast.lv and has technical specifications for three different models – EE100, EE120, and EE150. The product operates on a voltage range of 220-240V~ and a frequency of 50Hz. It has a power output ranging between 32W to 40W, depending on the model. The product has a noise level of 34-36 dB(A) and has protection against environmental impact with an IPX4 rating. The product comes with a timer function and a moisture level regulator that can be set between ~60%RH to ~90%RH for automatic operation.

Product Usage Instructions

Before using the ventilator, make sure to read the user manual carefully. Check for any damage to the product before unpacking it. Keep the purchase receipt and warranty card safely as it will be required for any claims. Before installation, check if the electrical supply voltage and frequency match the specifications of the product. Ensure correct polarity while connecting the product to the electrical supply. The product can be used by children above 8 years of age and people with physical or mental disabilities who have been briefed on safety instructions. However, children should not operate or maintain the product without adult supervision. To install the ventilator, turn off the power supply to the intended installation location and seek professional assistance from an electrician. The product comes with two motor bearings for additional support. The ventilator is connected to the electrical supply through a removable cord and is operated by pulling down on the cord located at the bottom of the product. The timer function of the product can be set using the regulator located on the control panel (Zm.6). The timer can be set between 1 to 30 minutes. The moisture level regulator can also be set between ~60%RH to ~90%RH using the regulator located on the control panel (Zm.7). The product operates automatically when the moisture level reaches the set value or can be turned on using the switch (S1) or light switch (Zm.5). Do not connect the product’s power supply switch (S1) to an LED light indicator.

WARNINGS

  • Caution! Read the manual carefully before installing and using of the fan.
  • Caution! Make sure that there are no visual defects when unpacking the fan.
  • Caution! We do recommend you to save the bill of purchase with stamped guarantee coupon, for the purpose of possible reclamation. Otherwise guarantee will be not in legal force.
  • Caution! Before connecting to the mains supply ensure that mains voltage (V) and frequency (Hz) corresponds to the parameters on the rating plate.
  • Caution! When connecting the fan, it is important to follow the polarity (see Installation and Maintenance)
  • Caution! This device may be used by children starting from age of 8 as well as people with physical or mental disorders, given that they are familiar with the manual and safety provisions in respect to this device. It is prohibited for children to play with the device. Children may not carry out maintenance or cleaning of this device without supervision of adults.
Technical information EE100 EE120 EE125 EE150
Voltage (V) 220 – 240
Phase (Hz) 50
Power (W) 15 16 16 20
Suction power (m3/h) 100 145 150 200
Noise level: 3m distance, Lp A dB(A) 32 34 36 40
Protection against environmental factor IPX4
RPM 2550 2400 2360 2100
Ambient temperature +5°C … +40°C
Weight (kg) 0,37 0,44 0,44 0,56

Sizes,

mm

| EE100| EE120| EE125| EE150
---|---|---|---|---
A| 140| 165| 165| 190
B| 140| 165| 165| 190
C| 80| 80| 80| 80
D| 99| 119| 124| 149
E| 16| 16| 16| 16

Installation and Maintenance

Caution! Before installation, disconnect the power network where you are planning on installing the fan.

Caution! Installation may be carried out only by a qualified electrician.

EUROPLAST-EE100-eextra-Series-EE-Exhaust-Fan-FIG-5 EUROPLAST-EE100-eextra-Series-EE-Exhaust-Fan-
FIG-7

Before mounting, the cover part of the ventilator must be removed by pressing with a screwdriver on two locks under the case (Image 1). The ventilator must be mounted in a ventilation duct by attaching the ventilator on the wall by the use of screws (Image 2). The base model ventilators, ventilators with a switch (W), ventilators with a timer (T), ventilators with a humidity sensor and timer (HT) must be connected to the electrical network. Under the cover, there are N-L or N-L-S clamps to which the electrical network must be properly connected (Images 3-5). When connecting the ventilator with the voltage, it is important to observe polarity and connect the line wire with L-clamp and neutral wire with N-clamp. When connecting the fan to electricity, it is important to take into account polarity and connect the live wire to the Terminal L and the neutral wire to the Terminal N. In case if the fan is directly connected to the electric power network, the power network must be equipped with a switch that ensures safe disconnection of the power supply.

Bearing B
In addition, the fan is equipped with two ball bearings inside of the electric motor.

Switch and Cable WP
A fan that is equipped with a pull-down switch and cable shall be connoted to a power outlet. The fan is turned on and off by pulling down the string that is located on the bottom of the fan.

Timer T
The fan is turned on by the S1 power switch (Drawing 4) or by turning on the light (Drawing 5). After turning off the light or the switch, the fan continues its operation for a specific time interval that is set up by a controller. This interval may be 1 to 30 minutes long.

Caution! The fan power switch S1 (fig.4, fig.5) must not be equipped with an LED light indicator.

Humidity Sensor HT

The fan is equipped with a humidity level control that may be used to set the level of humidity from ~60%RH – ~90%RH and a delay control that may be used to set the delay from 1 to 30 min. The fan is turned on automatically when a certain humidity level is reached in the room or it may be turned on manually by a switch. Connection diagram is shown in Drawing 4-5. The fan is turned off after a pre-set time interval. Humidity “H” and delay “T” controllers are located on the control unit (Drawing 7). To set the maximum humidity level (~ 90% RH) for moisture regulator “H” need turned fully clockwise.

Caution! The fan power switch S1 (fig.4, fig.5) must not be equipped with an LED light indicator.

Timer, Cable, and Switch TWP
A fan that is equipped with a timer, cable, and switch is turned on by a pull- down switch. It will turn off after the pre-set time interval. To adjust the timer, see section “Timer T”.

Humidity Sensor, Timer, Cable, and Switch HTWP
A fan that is equipped with a humidity sensor, cable, and switch is turned on by a pull-down switch or after a certain humidity level is reached in the room. It turns on after the pre-set time interval or if humidity in the room drops to a certain level. To adjust the humidity sensor, see section “Humidity Sensor HT”.

12V motor – 12
The fan is equipped with a 12V motor. A fan intended to be installed together with 12V power supply.

  • Caution! Fans with electronic control unit must be adjusted before they are connected to the power network.
  • Caution! If the potentiometer is set to “1 min”, the fan will turn on for a couple of seconds after connected it to the power network.

Guarantee

Producer guarantee is 24 months. In the case of damages contact the place of trade.

The guarantee does not cover:

  1. noted mechanical or other damages
  2. mechanical or other damages caused by incorrect or improper usage, misuse, abuse or neglect
  3. mechanical or other damages caused by incorrect installation or by product’s incorrect fitting to insufficient or unsuitable power
  4. mechanical or other damages caused by ignoring the instruction manual conditions

A guarantee does not cover natural wear of the product.

Utilization
Information for Users on Disposal of Old Equipment. This symbol indicates that the electrical and electronic equipment should not be disposed of as general household waste at its end-oflife. Instead, the products should be handed over to the appliance collection points for the recycling of electrical and electronic equipment, recovery and recycling in accordance with your national legislation and the Directive 2002/96/EC and 2006/66/EC.

SIA “EIROPLASTS” Granīta iela 32/6, Salaspils novads, Acone, Latvija, LV-2119

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>