- Product Information
- Product Usage Instructions:
- Log book and instructions for use
- Type plate of Tripod and accessories
- Overview
- Instruction manual – safety area
- Technical specifications – tripod Type DB-A3 / DB-A3 XL
- Creation of operational readiness for securing persons
- Attachment points according to EN 795: 2012 Type B
- Adjustable rubber feet
- Optional accessories
- Possible applications for securing 2 persons against falling and for
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IKAR TypeDB-A3 Tinez Workwear Singing Rock Tripod
Product Information
Specifications:
- Product Name: Dreibaum DB-A3 Anschlageinrichtung
- Standards: EN 795:2012 Type B, CEN/TS 16415:2013
- Maximum Load Capacity: 300 kg
- Manufacturer: IKAR GmbH
- Country of Manufacture: Germany
Product Usage Instructions:
Setting up the Dreibaum DB-A3:
- Ensure the Dreibaum is set up in a vertical position.
- Fold out the legs outward as shown in the manual.
- Secure the legs by pushing them onto the locking pins.
- Adjust the legs to compensate for uneven ground.
- Ensure the Dreibaum is stable and on a secure footing.
Securing Anchorage Points:
Follow the guidelines provided for securing anchorage points according to
EN 795:2012 Type B.
Optional Components:
Mount optional components such as the safety post on the leg where the
identification plate is attached.
Important Notes:
Always ensure you have thoroughly read and understood the instruction
manual before using the product. Adhere to all safety guidelines and
standards.
Additional Resources:
For more information and specific details, refer to the comprehensive user
manual provided with the product.
FAQ – Frequently Asked Questions:
-
Q: What is the maximum load capacity of the Dreibaum DB-A3?
A: The maximum load capacity of the Dreibaum DB-A3 is 300 kg. -
Q: How many people can the Dreibaum DB-A3 accommodate?
A: The Dreibaum DB-A3 can accommodate up to 2 persons.
Log book and instructions for use
Tripod DB-A3
Load fastening device according to EN 795:2012 Type B and CEN/TS 16415:2013
- ALWAYS KEEP THIS BOOKLET WITH THE DEVICE!
- CAREFULLY READ THESE INSTRUCTIONS BEFORE USING THIS PRODUCT!
- Tripod DB-A3, according to EN 795 Type B:2012-10, CEN/TS 16415:2013-04, EN Regulation 2016/425
date of purchase__
date of first use__
http://ikar-gmbh.de/index.php/de/service/download
Revision next revision
Position/Item| | | |
---|---|---|---|---
Functional test of the locking pins| | | |
Inspection of screw connections for tight fit| | | |
Tripod deformation inspection| | | |
Inspect grommets at attachment points| | | |
Functional test of rope pulley and snap-hook| | | |
Functional test of the locking pins| | | |
visual check for cracks / corrosion| | | |
Inspect the function and condition of the wheels| | | |
(optional) Inspect the attachment rack of the fall protection system
(optional)| | | |
check type plate legibility| | | |
Date of certification:
signature of the inspector:| | | |
Purposes: observed defects:| | | |
Comments:| | | |
- The IKAR fall protection device HRA with rescue lifting gear must be inspected according to the inspection and maintenance instructions for IKAR fall protection systems!
- This log book with instructions for use belong to the Tripod DB-A3 according to EN 795 Type B:2012-10, CEN/TS 16415:2013 and must be available at the location of use. If the device is resold, these instructions for installation and use must be enclosed in the national language.
| | | | |
---|---|---|---|---|---
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
| | | | |
Type plate of Tripod and accessories
- product type
- product
- standard/year
- date of next inspection
- manufacturer
- product serial no
- year of manufacture
- Permissible load
- consider instructions for use
- supervision
Overview
The image (Illus. 4) shows the equipment with *optional accessories: IKAR fall protection device HRA with rescue lifting gear and fixture. Make sure that you have thoroughly read the instruction manual and understood its contents before operating the device. The technical specifications and the corresponding included instruction manual for the IKAR fall protection device HRA with rescue lifting gear must be strictly observed!
Make sure that you have thoroughly read the instruction manual and understood its contents before operating the device. The technical specifications and the corresponding included instruction manual for the IKAR fall protection device HRA with rescue lifting gear must be strictly observed!
Instruction manual – safety area
-
This anchoring device has been tested and approved for securing 1 person according to EN 795:2012 Type B and for securing 2 persons according to CEN/TS 16415:2013 against falling and for rescue. In combination with additionally required safety harnesses according to EN 361, IKAR fall arresting devices according to EN 360, IKAR fall arresting devices of type HRA with rescue lifting equipment according to EN 360 / EN 1496, it must be ensured that the force that acts on the user during the arresting process is limited to max. 6 kN. The anchoring device and fall arresting devices are to be used only as intended.
Note: The IKAR fall protection device HRA with rescue lifting gear is not included in the delivery scope! -
A non-observance of the instruction manual can be hazardous to life. In case of a fall, the persons concerned must not be left hanging for more than 15 minutes in any case (shock risk).
-
A rescue plan considering any potential emergencies that might occur during this type of work must be available.
-
The stop device may only be used by properly trained and experienced persons. Health impairments are not admissible (e.g. alcohol, narcotics, drug or circulatory troubles)!
-
An IKAR fall protection system HRA with rescue lifting gear can only protect one person when in service; but however can be used successively by several persons.
-
The IKAR tripod DB-A3 must always be vertical and stable when set up as an essential safety factor. Attention: The tripod must never be used on oily or otherwise slippery surfaces!
-
The equipment should preferably be positioned perpendicularly above the head of the person to be rescued in order to avoid swinging in case of a fall. After having attached the IKAR fall protection device HRA to the fixture in on the IKAR tripod and inserting the extendable lanyard into the guide pulley, the end (snap-hook) must be attached to the receiver grommet of the safety harness. Verify the correct function of the snap-hook. The working person is now safely protected.
-
Check the legibility of the product identification prior to every use and perform a visual inspection of the stop device and its attachments for visible defects (according to the list on page 2).
-
Equipment that is damaged or has been exposed to stress due to a fall or in case of doubt about the safe condition of the equipment must be put out of operation immediately! It may only be used again after an inspection and written release by a qualified person.
-
Depending on the exposure, but at least once in twelve months, the stop device, i.e. the IKAR tripod and the optional fall protection device must be inspected by the manufacturer or persons trained and authorised by the manufacturer. This must be documented in the included inspection log books. The effectivity and durability of the IKAR tripod and the optional IKAR fall protection device depend on the regular inspection.
-
Repairs may be done by the manufacturer only.
-
DGUV Rules 112-198 and 112-199 must be observed.
-
The permissible load of the anchoring device corresponds to EN 795:2012 Type B for securing and rescuing 1 person and CEN/TS 16415:2013 for maximum 2 persons.
-
Protect the IKAR tripod DB-A3 and also the optional IKAR fall protection device from welding flames and sparks, fire, acids, leaches as well as extreme temperatures and corrosive environmental impacts. Protect tripod from impact damages during transport.
-
Modifying or complementing the equipment can be hazardous to life.
Technical specifications – tripod Type DB-A3 / DB-A3 XL
Tripod | Type DB-A3 | Type DB-A3 XL |
---|---|---|
Max. load | 2 Persons | 2 Persons |
Height adjustment range | 1,34 m – 2,19 m | 1,81 m – 2,91 m |
Mounting diameter | 0,96 m – 2,21 m | 1,25 m – 2,90 m |
Weight (without HRA device) | 24 kg | 30 kg |
max. load capacity | 300 kg | 300 kg |
Creation of operational readiness for securing persons
Set up the tripod vertically (Illus. 5).
- Fold legs outwards by pressing on the locking pin (Illus. 6) and pivoting the leg outwards until you hear it snap in.
- Fold legs outwards by pressing on the locking pin 1 (Illus. 6) and pivoting the leg outwards until you hear it snap in.
- In order to adjust the height of the individual extendable legs, unlock the locking pin (position 9) by pressing with the thumb (Illus. 8) and sub-sequently pulling it out.
- Extend the legs to the desired length and secure the latter with locking pins. Repeat this procedure for the remaining 2 legs. Finally, align and position the tripod. Ensure safe stand.
- To disassemble the tripod, repeat the above procedure in reverse order.
Attachment points according to EN 795: 2012 Type B
The attachment points (Illus. 9) is suited for attaching fall protection systems according to EN 360 and in combination with safety harnesses according to EN 361 for a maximum of 2 persons.
Adjustable rubber feet
- The rubber feet feature a fold-away design for better adaption to ground conditions.
- The horizontal position (Illus. 10) is recommended for hard and stable ground.
- The vertical, tip-standing position is recommended for softer ground (Illus. 11) in order to prevent slipping.
Optional accessories
IKAR fall protection device HRA with rescue lifting gear:
-
The IKAR fall protection device HRA with rescue lifting gear is attached to the leg bearing the type plate with the fixture.
-
Mount the fixture (Illus. 12, 13 and 14) to the leg in a way that enables the safety staff to ergonomically operate the rescue lifting handle. The proper clamping force of the fixture is obtained through the length (45.8mm) of the included spacing sleeves.
-
The fastening torque of the hexagon screws M 10 x 80, quality 8.8 is 49Nm. The locking bar must be positioned according to the device size. The fastening torque of the cylinder-head bolts M 8 x 30, quality 8.8 is 6 Nm. Insert the IKAR HRA device into the fixture. The IKAR HRA device is secured with a locking pin.
-
Attention: Only mount IKAR fixtures. Only IKAR devices may be mounted in IKAR fixtures.
-
The 3 integral deflection rollers (Illus. 15) serve for guiding and redirecting the steel rope of the IKAR fall arresting device HRA and/or other ropes, e.g. of the personnel winch PLW.
-
Note: The IKAR HRA device retracts the rope automatically as long as the rescue lifting function is not engaged.
Possible applications for securing 2 persons against falling and for
rescuing in combination with the additional anchor point
Illus. 16:
- One person enters a shaft, for example, fastened to a fall arresting device of type HRA and the latter‘s snap hook to the fall arrest eyelet of his safety harness (refer to instruction manual for the equipment). The safety supervisor has the option, for example, to use a fall arresting device in combination with a safety harness for fastening to the additional anchor point. Even during an emergency rescue, the safety supervisor is always protected against falling.
- However, it is not possible to rule out the possibility of injury to the safety supervisor or damages to the personal safety equipment resulting from impact with edges or objects in the event of a fall into a shaft, for example.
Manufacturer : IKAR GmbH
- Nobelstr. 2
- 36041 Fulda
- GERMANY
- Tel.: +49 (0)661 22050 www.ikar-gmbh.de
Engaged body:
- DEKRA EXAM GmbH ·
- D-44809 Bochum / GERMANY ·
- CE 0158
- controlled and audited by:
- DEKRA Testing and Certification GmbH