EATON B064-016-02-IPH KVM Switch User Manual

June 2, 2024
EATON

EATON LOGO Installation Instructions
NetDirector® Cat5 IP KVM Switches
B064-016-02-IPH/B064-016-04-IPH/B064-032-01-IPH/
B064-032-02-IPH/B064-032-04-IPHEATON B064 016 02 IPH KVM
Switch
Purchased product may differ from image.

Installation

For complete installation instructions, refer to the Owner’s Manual

Rack Mounting

EATON B064 016 02 IPH KVM Switch - Rack Mounting

  1. Use the M3x8 Phillips head hex screws provided with the rack mount kit
  2. Use user supplied hardware to attach to the rack

Single-Stage Installation

EATON B064 016 02 IPH KVM Switch - Single Stage
Installation

Stacking
The KVM switch can be placed on any level surface that can safely support its weight plus the weight of attached cables. When placing the KVM switch on a desktop, remove the backing material from the rubber feet that came with this package and affix them to the switch’s bottom panel at the corners.
Note: To ensure adequate ventilation, allow at least 2 inches (5 cm) on each side, and 5 inches (13 cm) at the back for power cord and cable clearance.

Rack Mounting
The KVM switch can be mounted in a 19-in (1U) rack. The rack mount brackets can be installed on either the front or the back of the unit so that it can be mounted to the front or back of the rack.

  1. Depending on whether you front-rack mount or rear-rack mount the unit, remove the two screws located on both sides of the front or back of the unit.
  2. Use the screws supplied with the rack mount kit to attach the rack mount brackets to the front or rear of the unit.
  3. Position the device in the front or rear of the rack and align the holes in the mount brackets with the holes in the rack.
  4. Secure the rack mount brackets to the rack using user-supplied screws.

Single-Stage Installation
In a single-stage installation, there are no additional KVM switches cascaded or daisy-chained from the B064-Series KVM. To set up a single-stage installation, refer to the following instructions and the corresponding installation diagrams.

  1. Make sure that power to all the devices you will be connecting, including all pre-existing devices on the installation, have been turned off.
  2. Optional: Plug your Local Console’s keyboard, monitor, and mouse into the KVM’s Local Console Ports.
  3. Use Cat5e cable to connect any available KVM port to a Server Interface Unit (SIU): B055-001-PS2 (PS/2), B055-001-SER (Serial), B055-001-USB (USB) or B055-001-USB-V2 (USB with Virtual Media).
  4. Connect the Server Interface Unit to the computer/server.
  5. Repeat steps 3 and 4 for each computer/server you are connecting.
  6. Connect a Cat5e cable from the network into the KVM switch’s primary network port (LAN 1).
  7. Optional: Connect a second Cat5e cable from the network into the KVM switch’s backup (secondary) network port (LAN 2).
  8. Optional Dial-In Modem Connection: Use Cat5e cable to connect the KVM switch’s Modem port to the included RJ45 to DB9 Adapter and connect the adapter’s DB9 connector to the modem’s DB9 port.
  9. Use the included grounding wire to ground the unit. Connect one end of the wire to the grounding terminal, and the other end of the wire to a suitable grounded object.
  10. Plug the included power cords into the KVM switch’s Power Sockets, and then into a Tripp Lite Surge Protector, Uninterruptible Power Supply (UPS) or PDU.
  11. Turn on the power to the KVM switch. Once it is powered up, turn on the power to the connected computers.

EATON LOGO Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2024 Eaton
All Rights Reserved
Publication No. 23-11-049 / 93-49AC_revA
January 2024
Eaton is a registered trademark.
All trademarks are property
of their respective owners.

Documents / Resources

| EATON B064-016-02-IPH KVM Switch [pdf] User Manual
B064-016-02-IPH KVM Switch, B064-016-02-IPH, KVM Switch, Switch
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals