RONIX RC-2512 Quiet Air Compressor Instruction Manual

June 2, 2024
Ronix

RONIX RC-2512 Quiet Air Compressor

PRODUCT SPECIFICATIONS

Model RC-2512
Tank Capacity 25L
Includes 2Air Filter, Two Wheels, 1

Rubber base 1 pushrud

Air Delivery| 100L/min
Speed| 2800 RPM
Max Pressure| 0.8 MPa
Power| 1380W
Weight| 23kg
Voltage| 220-240V
Frequency| 50-60Hz
Supplied in| Ronix Color box
Safety Valve Opening| 0.88MPa
restart pressure| 0.5MPa
use pressure range| 0-0.8MPa

PARTS LIST

RONIX-RC-2512-Quiet-Air-Compressor-fig-1

GENERAL POWER TOOL SAFETY WARNINGS

WARNING

  • Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and or serious injury.
  • Save all warnings and instructions for future reference.
  • The term “power tool” in the warnings refers to your mains-operated (corded) power tools or battery-operated (Cordless) Power tools.

WORK AREA SAFETY

  • Keep the work area clean and well-lit. Cluttered or dark areas invite accidents.
  • Don’t operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks that may ignite the dust or fumes.
  • Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control.

ELECTRIC SAFETY

  • Power tool plugs must match the outlet. Never modify the plug in any way. Don’t use any adaptor plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
  • Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
  • Don’t expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
  • Don’t abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep the cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increased the risk of electric shock.
  • When operating a power tool outdoors, use an extension cord suitable for outdoor use. Using a cord suitable for outdoor use will reduce the risk of electric shock.
  • If operating a power tool in a damp location is unavoidable, use a residual current device (RCD) protected supply. The use of an RCD reduces the risk of electric shock.
  • Use of power supply via an RCD with a rated residual current of 30mA or less is always recommended.

PERSONAL SAFETY

  • Stay alert, watch what you are doing and use common sense when operating a power tool. Don’t use a power tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
  • Use personal protective equipment. Always wear eye protection. Protective equipment such as dust masks, non-skid safety shoes, hard hats, or hearing protection used for appropriate conditions will reduce personal injuries.
  • Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents.
  • Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
  • Don’t overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
  • Dress properly. Don’t wear loose clothing or jewellery. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.
  • If devices are provided for connection of dust extraction and collection facilities, ensure these are connected and properly used. The use of dust collection can reduce dust-related hazards.

POWER TOOL USE AND CARE

  • Don’t force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed.
  • Don’t use the power tool if the switch doesn’t turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
  • Disconnect the plug from the power source and/or the battery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
  • Store idle power tools out of the reach of children and don’t allow persons unfamiliar with power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
  • Maintain power tools. Check for misalignment or binding of moving parts, breakage o parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
  • Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
  • Use the power tool, accessories tool bits etc. following the instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.

SERVICE

  • Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
  • Follow instruction for lubricating and changing accessories.
  • Keep handles dry, clean and free from oil and grease.

AIR COMPRESSOR USE AND CARE

  • Do not exceed the pressure rating of any component in the system.
  • Protect material lines and air lines from damage or puncture. Keep hose and power cord away from sharp objects, chemical spills, oil, solvents, and wet floors.
  • Check the tank before each use, making, certain all connections are secure. Do not use if the defect is found.
  • Release all pressures within the system slowly. Dust and debris may be harmful.
  • Store idle air compressors out of the reach of children and other untrained persons. Air compressors are dangerous in the hands of untrained users.
  • Maintain air compressors with car. Follow maintenance instructions. Properly maintained products are easier to control.
  • Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the product’s operation. If damaged, have the air compressor serviced before using. Many accidents are caused by poorly maintained products.
  • Keep the exterior of the air compressor dry, clean and free from oil and free from oil and grease. Always use a clean cloth when cleaning. Never use break fluids, gasoline, petroleum-based products, or any strong solvents to clean the unit.
  • Following this rule will reduce the risk of deterioration of the enclosure plastic.

SPECIAL SAFETY RULES

  • Know your air compressor. Read operator’s manual carefully. Learn its applications and limitations, as well as the specific potential hazards related to this product. Following this rule will reduce the risk of electric shock, fire or serious injury.
  • Drain tanks of moisture after each day’s use. If the unit will not be used for a while, it is best to leave the drain valve open unit such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion on the inside of tanks.
  • Risk of fire or explosion. Do not spray flammable liquid in a confined area must be well-ventilated Do not smoke while spraying or spray where a spark or flame is present. Keep compressors as far from the sparing areas as possible, at least 4.5m (15 feet) from the spraying area and all explosive vapours.
  • Risk of bursting. Do not adjust regulator to result in output pressure greater than the marked maximum pressure of attachment. Do not use at a pressure greater than 10 bar.
  • If connected to a circuit protected by fuses, use time delay fuses with this product.
  • To reduce the risk of electric shock, do not be exposed to rain. Store indoors.
  • Inspect tanks yearly for rust, pin holes, or other imperfections that could cause them to become unsafe.
  • Never weld or drill holes in the air tanks.
  • Make sure the hose is free of obstructions or sangers.
  • Entangled or snarled hoses can cause loss of balance or footing and may become damaged.
  • Use the air compressor only for its intended use. Do not alter or modify the unit from the original design or function.
  • Always be aware that misuse and improper handling of this product can cause injury to yourself and others.
  • Never leave a tool unattended with the air hose attached.
  • Never point any air tool toward yourself or others.
  • Do not operate this air compressor if it does not contain a legible warning label.
  • Do not continue to use a tool or hose that leaks air or does not function properly.
  • Always disconnect the air supply and power supply before making adjustments, servicing a product, or when a product is not in use.
  • Your tool may require more air consumption than this air compressor is capable of providing.
  • Always follow all safety rules recommended by the manufacturer of your air tool, in addition to all safety rules for the air compressor. Following this rule will reduce the risk of serious personal injury.
  • Never direct a jet of compressed air toward people or animals. Take care not to blow dust and dirt towards yourself or others. Flowing this rule will reduce the risk of serious injury.
  • Do not use this air compressor to spray chemicals.
  • Your lungs can be necessary in dusty environments or when spraying paint. Do not carry while painting.
  • Never use an electrical adaptor with this grounded plug.
  • Check damaged parts. Before further use of the air compressor or air tool, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mountings and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service centre.
  • Following this rule will reduce the risk of shock, fire, or serious injury.
  • Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. A wire gauge size (A.W.G) of at least 14 is recommended for an extension cord 7.5 m or less in length. A cord exceeding 15 m is not recommended. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
  • This equipment incorporates parts, such as snap switches, receptacles, and the like that tend to produce arcs or sparks and, therefore, when located in a garage, it should be in a room or enclosure provided for the purpose, or should be 460mm or more above the floor.
  • Never store a tool with connected. Storing the tool with an air-connected can result in unexpected firing and possible serious personal injury.
  • Protect your lungs. Wear a face or dust mask if the operation is dusty. Following this rule will reduce the risk of serious personal injury.
  • If the power supply cord is damaged, it must be replaced only by the manufacturer or by an authorized service centre to avoid risk.
  • Save these instructions. Refer to them frequently and use them to instruct others who may use this product.
  • If you loan someone this product, loan them these instructions also.
  • The machine shall be connected to a circuit protection device (fuse or circuit breaker). The protection device shall be set at 8 A current, and the user shall do the necessary test according to clause 18.2.2 of EN 60204-1:2006 to check if the protection device is suitable for use.
  • When the machine is in operation, many parts of the machine may cause a high temperature. Use gloves to avoid injuries resulting from a high temperature. This appliance is not intended for use by persons (including children) with reduced Physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

ASSEMBLY

UNPACKING
This product requires assembly. Carefully remove the product and any accessories from the box.

  • WARNING
    This product requires assembly. Carefully remove the product and any accessories from the box.

  • WARNING
    Do not use this product if any parts on the packing list are already assembled to your product when you unpack it. Use of a product that may have been improperly assembled could result in serious personal injury. Inspect the product carefully to make sure no breakage or damage occurred during shipping. Do not discard the packing material unit you have carefully inspected and satisfactorily operated the product.

  • WARNING
    If any parts are damaged or missed, do not operate this product until the parts are replaced. Use of this product with damaged or missing parts could result in serious personal injury.

  • WARNING
    Do not attempt to modify this product or create accessories not recommended for use with this product. Any such alteration or modification is misused and could result in a hazardous condition leading to possible serious personal injury.

  • WARNING
    Do not connect to power supply until assembly is complete. Failure to comply could result in accidental starting and possible serious personal injury.

APPLICATIONS
Air compressors are utilized in a variety of air variety of air system applications. Match hoses, connectors, air tools, and accessories to the capabilities of the air compressor. You may use this product for the purposes listed below:

  • Operating some air-powered tools
  • Operating air accessories such as air nozzles and tire inflators.

TO MOVE THE AIR COMPRESSOR
Ensure the air compressor is unplugged, and make sure the power cord is secured in the cord warp.

  1. Facing the back of the air compressor, grasp the handle firmly with two hands.
  2. Live the air compressor toward you until it balances on the wheels.
  3. Push the unit along to the desired location. Lower their air compressor unit it sits securely on a flat surface. dehumidifier role: The dehumidifier tank absorbs and gathers droplets of water mixed in the compressed air to longers the life of the component working by compressed air.

BREAK- IN PERIOD
Before first use, run the air compressor at zero tank pressure with the drain valves fully open for 30 minutes.
TURNING THE AIR COMPRESSOR ON/OFF

  1. With the air compressor plugged in, pull the power switch to the ON position to power the compressor on.
  2. To turn the air compressor off, push the power switch to the OFF position.

NOTE
When the compressor is in the ON position, the air compressor will automatically turn back on when the designated tank air pressure is set. It will also shut off again when the desired limit. It will also shut off again when the desired pressure is reached.
WARNING
Never exceed the air tool’s pressure rating as recommended by the manufacturer. When using this air compressor as an inflation device, always follow the maximum inflation guidelines stated by the manufacturer of the item being inflated.
WARNING
Always ensure the switch is in the OFF (O) position and the regulator pressure gauge reads zero before changing air outlet. Failure to do so could result in possible serious personal injury.

USING THE AIR COMPRESSOR

  1. Ensure the power switch is in the OFF (O) position and the air compressor is unplugged.
  2. If not already installed, attach the hose to the compressor
  3. Attach 6.35 mm (1/4 in.) NPT quick- connect air fitting to the accessory or tool you intend to use.
  4. Insert the other end of the quick connect air fitting to the quick coupler on the open end of the hose.
  5. Connect the power cord to the power supply.
  6. Turn the switch ON (1).
  7. Pull out and rotate the pressure regulator knob to desired line pressure at the outlet; turning the counterclockwise regulator knob to desired line pressure. Turning the knob clockwise increases air pressure at the outlet; turning counterclockwise reduces air pressure at the outlet.
  8. Following all safety precautions in the air tool manual. You may now proceed to use your air-powered tool.

WARNING
Air-powered tools may require more air consumption than this air compressor is capable of providing. Check the tool manual to avoid damage to the tool or risk of personal injury.

  1. Control the amount of airflow with the pressure regulator knob. Turning the knob fully counterclockwise will completely stop the flow of air.

NOTE
Always use the minimum amount of pressure necessary for your application. Using a higher pressure than needed will drain air from the tank more rapidly and cause the unit to cycle on more frequently.

  1. When finished, always drain the tank and unplug the unit. Never leave the unit plugged in and/or running unattended.
  2. Recommended for the use of a residual current device with a rated residual current of 30mA or less.

DRAINING THE TANKS
To help prevent tank corrosion and keep moisture out of the air, used, the air tanks of the compressor should be drained daily.

TO DRAIN

  1. Turn the air compressor off.
  2. Pull the ring on the pressure relief valve to release until the pressure gauge reads less than 1.4 bar.
  3. Release the ring.
  4. Rotate the flush valve 90 degrees to pour the tank water out.

RONIX-RC-2512-Quiet-Air-Compressor-fig-4

DEHUMIDIFIER ROLE
dehumidifier tank absorbs and gathers droplets of water mixed in the compressed air to longers the life of the component working by compressed air.

NOTE
Condensate is a polluting material and should be disposed of in compliance with local regulations.

  1. If drain valves are clogged, release all air pressure, remove and clean valves, and then reinstall.

DANGER

Unplug the air compressor and release all air from the tanks before servicing. Failure to depressurize tanks before attempting to remove the valve causes serious personal injury. Rotate drain valves clockwise until tightly closed.

CHECKING THE SAFETY VALVE

WARNING
Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failure to heed this warning could result from death or serious personal injury. The safety valve will automatically release air if the air tank pressure exceeds the preset maximum. The valve should be checked before each day of use by pulling the ring by hand.

  1. Turn the air compressor on and allow the tanks to fill. The compressor will shut off when the pressure reaches the preset maximum.
  2. Turn the air compressor off.
  3. Pull the ring on the safety valve to release air for three to five seconds.
  4. The ring pin must be pushed back into position to stop the flow so air at high pressure.

WARNING
If air leaks after the ring has been released, or if the valve is stuck and cannot be actuated by the ring, do not use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could result in serious personal injury.

MAINTENANCE

WARNING

  • When servicing use only identical replacement parts.
  • Use of any other parts may create a hazard or cause product damage.

WARNING

Always wear eye protection with side shields. Failure to do so could result in objects being thrown into your eyes resulting in possible serious injury.

WARNING

Always release all pressure, all pressure, disconnect from the power supply, and allow the unit to cool to the touch before cleaning or making repairs on the air compressor.

GENERAL MAINTENANCE

Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and be damaged by their use. Use clean cloths to remove sort, dust, oil, grease, etc. AS a routine part of air compressor maintenance, it is also advised that the oil is routinely checked for proper levels.

WARNING

Do not at any time let brake fluids, gasoline, petroleum-based products, penetrating oils, etc., come in contact with plastic parts, Chemicals can damage, weaken or destroy plastic which may result in serious personal injury. Electric tools used on fibreglass material, wallboard, speckling compounds, or plaster are subject to accelerated wear and possible premature failure because the fiberglass chips and grindings are highly abrasive to bearings, brushes, commutators, etc. Consequently, we do not recommend using  this product for extended work on these types of materials. However, if you do work with any of these materials, it is extremely important to clean the product using compressed air

BEARING LUBRICATION
All of the bearings in this product are lubricated with a sufficient amount of high grade lubricant for the life of the unit under normal operating conditions. Therefore, no further lubrication is required.

ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing of as waste. The machine, accessories and packaging should be sorted for environmental-friendly recycling

TROUBLESHOOTIN

PROBLM CAUSE POSSIBLE SOLUTION




Compressor will not run

| Loss of power or overheat- ing| Check for proper use of extension cord
NO electrical power| Check to be sure unit is plugged in
Blown shop/house fuse| Check fuse/ breaker
Shop/house breaker open| Replace shop/house blow fuse
Current limiting protector open| Reset shop/house breaker, determine why problem happened
Pressure switch bad| Motor will restart when cool
Tank is full of air| Compressor will tum on when tank Pressure drops to cut- in pressure



Motor hums but can- not run or runs slowly

| Low voltage| Check with voltmeter
Wrong gauge wire or length of extension cord| Check for proper gauge wire and cord length
Shorted or open motor winding| Take compressor to service center
Defective check valve or unloader| Take compressor to service center



Current limiting pro- tector

Protector cuts out repeatedly

| LOW voltage| Check with voltmeter
Lack of proper ventilation/ room temperature too high| Move compressor to well- ventilated area


Wrong gauge wire or length of extension cord

| ****

Check for proper gauge wire and cord length



Air tank pressure drops when compressor shuts off

| Loose connections (fitting ,

tubing, etc.)

| Check all connection with soap and water solution and tighten
---|---|---
Loose drain valve| Tighten drain valve



Check valve leaking

| Take compressor to service center DANGER

Do not disassemble check valve, tank drain

valves or safety relief valve with air in tank- bleed tanks.

Excessive moisture in Discharge air| Excessive water in air tanks| Drain tanks
High humidity| Move to area of less humidity; use air-line

filter



Compressor runs contin- uously

| Defective pressure switch| Take compressor to service center
Excessive air usage| Take compressor to service center


Piston ring are worn

| Decrease air usage; compressor not Large enough for tools requirement
Replace piston rings; Air intel filter is blocked,

call customer service for assistance

Air output lower than normal| Broken inlet valves| Tack compressor to service center
Connections leaking| Tighten connections

www.ronixtools-com