dahl 611-PRPX3-31 Dual Outlet Valves Instructions
- May 15, 2024
- DAHL
Table of Contents
dahl 611-PRPX3-31 Dual Outlet Valves
Product Information
Specifications
- Model: 611-PRPX3-31
- Connection Type: F1960 Cold Expansion for PEX-A, Compression for Copper Pipe and Plastic Tube
- Material: Various (Refer to manufacturer’s instructions)
- Compatibility: PEX-A tubing, Copper pipe, Plastic tube
- Installation: Indoor plumbing systems
Product Usage Instructions
Installation Process
-
Turn off the water supply before starting the installation.
-
Install the product according to the specific connection type:
-
F1960 Cold Expansion Connection for PEX-A:
Follow the tube manufacturer’s instructions carefully. Ensure you do not mix PEX connections with Poly-B tubing. -
Compression on Copper Pipe: Clean, de-burr, and cut the pipe square. Slide the nut, ring, and valve onto the pipe in that order. Tighten firmly with a small wrench, avoiding over-tightening.
-
Compression on Plastic Tube: Follow the tube manufacturer’s instructions. Use any special ring, nut, or insert as needed.
-
-
Turn on the water supply after installation.
-
Check for leaks to ensure proper installation.
-
Adhere to local plumbing codes during installation to prevent any issues.
-
Avoid exposing the product to corrosive agents to maintain its longevity.
Frequently Asked Questions
Q: Can I use this product with Poly-B tubing?
A: No, this product is only compatible with PEX-A tubing for F1960 Cold Expansion connections. Using it with Poly-B tubing may lead to failures.
Q: What should I do if I encounter leaks after installation?
A: If leaks are detected after installation, first turn off the water supply. Check the connections for proper tightening and follow the manufacturer’s instructions. If leaks persist, seek professional plumbing assistance.
Instructions for 611-PRPX3-31
- Turn off water supply. Install product. Turn on water supply, check for leaks. dahl assumes no responsibility for failure due to improper installation. Abide by local plumbing codes. Do not expose to corrosive agents.
- F1960 COLD EXPANSION CONNECTION FOR PEX-A ONLY: Follow tube manufacturers instructions. Warning: Do not attempt to use PEX connections with Poly-B tubing or vice versa.
- COMPRESSION ON COPPER PIPE: Do not use pipe dope or PTFE tape. Pipe must be clean, de-burred, round, & cut square. Slide nut, then ring, then valve onto pipe.
- Tighten firmly with small wrench. DO NOT OVER-TIGHTEN. Compression on plastic tube:
- Follow tube manufacturer’s instructions; Special ring, nut, or insert may be required.
Exceptional Quality, Exceptional People.®