TASK power LP24HR12NDWWT50 Lighted Power Strip DV Instruction Manual

June 17, 2024
TASK power

TASK power logo LIGHTED POWER STRIP
installation instructions
January 2019

LP24HR12NDWWT50 Lighted Power Strip DV

Lighted Power Strip DV Series
Installation Instructions for LPS WITH Built-In Power Supply
General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

TASK power LP24HR12NDWWT50 Lighted Power Strip DV -
partsTurn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS.
Wiring for Combined Light and Receptacle Circuit – Non DimmableTASK
power LP24HR12NDWWT50 Lighted Power Strip DV - parts1 Step 1 Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK Romex wire to BLACK wire from receptacles and switch. Connect WHITE Romex wire to WHITE wire from receptacles and driver. Ground all GREEN wires to PEM studs inside of back frame.
Step 2 When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
Step 3 To terminate last LPS, use wire nuts on ends of wires.
Step 4 Snap cover in place and turn power on.

Wiring for Separate Light and Receptacle Circuits

TASK power LP24HR12NDWWT50 Lighted Power Strip DV -
parts2 Step 1 Secure LPS to wall by screwing into wall studs or use anchors provided. If running two circuits, one for receptacles, one for lighting, connect fixture wires to appropriate Romex wires. BLACK to BLACK. WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.
Step 2 When connecting 2 or more LPS fixtures, run Romex from fixture to fixture. Ground each section to the next.
Step 3 To terminate last LPS, use wire nuts on ends of wires.
Step 4 Snap cover in place and turn power on.
Wiring Diagram for Combined Light & Receptacle Circuit – Non DimmableTASK power LP24HR12NDWWT50 Lighted Power Strip DV -
parts3 Wiring Diagram for Separate Light & Receptacle CircuitsTASK power LP24HR12NDWWT50 Lighted
Power Strip DV - parts4 Lighted Power Strip RM Series
Installation Instructions for LPS WITHOUT Built-In Power Supply
General Guidelines

  • Power source MUST be a 20 amp branch circuit protected by a GFCI at the panel or GFCI prior to the connection at LPS.
  • All wiring must meet NEC® and local codes.
  • Light valance recommended.
  • Firmly insert plug straight into receptacle, applying equal pressure to both blades at the same time. Gently rock plug, if needed.

Turn power off at panel. Carefully pry open each piece with tool (provided). Insert Romex connector into knockout hole inside of back frame. Pull wires into LPS. TASK power LP24HR12NDWWT50 Lighted Power Strip DV -
parts6TASK power LP24HR12NDWWT50
Lighted Power Strip DV - parts7Remote Power Supply- 120V Entry
Step 1
Secure LPS to wall by screwing into wall studs or use anchors provided. Connect BLACK to BLACK, WHITE to WHITE. Ground all GREEN wires to PEM studs inside of back frame.
Step 2 When connecting two LPS, run Romex from fixture to fixture. Ground each section to the next.
Step 3 To terminate last LPS, use wire nuts on ends of wires.
Remote Power Supply-Low Voltage Entry
Step 4
Using appropriate knockout hole, pull low voltage wire from remote power supply into the low voltage space, connect BLACK wire (negative) to BLACK wire from lights and RED wire (positive) to RED wire.
Step 5 Snap cover in place and turn power on.

TASK power logo Customer Service: 800.445.6404
Design Services/Technical Support: 866.848.9094
TaskLighting.com
www.TaskLighting.com
DesignAndSupport@TaskLighting.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

TASK power User Manuals

Related Manuals