Naweti WH202AE Portable Nebulizer with Mesh Technology Owner’s Manual
- May 15, 2024
- Naweti
Table of Contents
- SYMBOL KEY
- SECURITY WARNING
- WARNINGS ON BATTERY USE
- PRECAUTIONS
- WARNINGS ON ELECTROMAGNETIC COMPATIBILITY
- PACKAGE CONTENTS
- DESCRIPTION OF THE APPLIANCE
- INDAICATOR LIGHT & OPERATION DESCRIPTION
- APPLIANCE PREPARATION
- INSTRUCTION FOR USE
- CLEANING and MAINTENANCE
- TROUBLE-SHOOTING
- DISPOSAL
- PRODUCT SPECIFICATIONS
- AFTER-SALES SERVICE AND WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
PORTABLE NEBULIZER
WITH MESH TECHNOLOGY
Model:WH202AE
Dear customer, Naweti wishes
to thank you for choosing this product.
Our name is synonymous with reliable,
high-quality products.
SYMBOL KEY
The following symbols appear in the instructions for use and on the appliance and its packaging.
| Warning – Warning regarding possible risk of injury or possible health
hazards.
---|---
| Note – Note providing importantinformation.
| The packaging is made of renewable material and can be recycled.
| Serial number.
| Please read this manual carefully before using.
| According to the degree of protection against direct and indirect contacts,
the following equipment is classified asa BF type.
| Dispose of in compliance with the provisions of Directive 2012/19/EU
regarding waste electrical and electronic equipment.
| CE label certifiesthat the device is compliant with the basic requirements
set out in the legislation concerning the safety on medical devices.
IP22| Degree of protection of electrical equipment covers, where the first
number indicates the degree of protection against penetration by solid
foreign bodies (from 0 to 6) and the second number the degree of protec- tion
against liquid penetration (from 0 to 8).
SECURITY WARNING
Before using the appliance, read the instructions for use carefully, paying
particular attention to the warnings regarding safety, which must be observed.
This manual must be considered part of the product and must be kept for its
entire life-cycle.
If the appliance is passed on to another owner, it must be provided together
with all the relevant documentation. If the manual is mislaid or for further
information or clarification, please contact Farmamed using the details
provided on the last page.
-
Before using the product, check that it is intact and has no visible damage. If you have any doubts, do not use the appliance and contact your retailer.
-
This appliance must be utilised for its intended use only and as described in the instructions for use. Any other use is to be considered improper and, therefore, potentially dangerous.
The manufacturer declines all responsibility for any damage caused by incorrect or improper use. -
The accessories mentioned in the user manual are intended for use with this device alone.
-
To prevent cross infection, the device is used only by a single patient.
-
This nebuliser is a medical device. Only follow your doctor’s instructions regarding the type and dose of the medicinal product to be used.
-
The nebulisation cycle lasts 10-20 minutes, during which time the device nebulises 1-8 ml of medicinal product; however, is must be always used as indicated by a doctor.
-
Keep the device out of the reach of babies and unsupervised children.
-
In the event of a fault and/or malfunction, switch the appliance off without tampering with it. Always contact your dealer when repair work is required.
-
Do NOT try to dismantle, repair or replace parts of this device yourself.
Treattheappliancewithcare,protectitfromblows,extremetemperaturechanges,humidity, dust, direct sunlight and sources of heat. -
Do NOT shake the device during use.
-
Do NOT allow liquids to penetrate inside the body of the appliance. Never immerse the applianceinwater. Never rinse it under running water. This appliance is not waterproof.
-
To avoid damage to the device, do not transport it or leave the medicinal product vessel full of medicinal product or distilled water, when not in use.
-
Do not use or store the device in humid places. Use the device within the temperature and humidity ranges included in “Product specifications”.
-
Do not use any high concentration or high viscosity liquids, as these may damage the mesh irreparably.
-
Do not use any medicines in powder form (even if dissolved.).
-
Unplug from the socket after using the adapter.
-
Switch the unit off immediately if it is defective or malfunctioning.
WARNINGS ON BATTERY USE
- If the appliance is not to be used for a long period, remove the batteries and store in a cool, dry place at room temperature.
- NEVER expose batteries to sources of heat and direct sunlight. Failure to observe this precaution may damage the batteries and/or cause them to explode.
- Do NOT incinerate batteries. Risk of explosion!
- Model: WH202AE is built-in lithium battery, please do not remove the battery.
- Keep batteriesoutofthe reachofchildren: swallowing batteries canbe fatal. Ifswallowed, seek medical advice immediately.
- The acid inside the batteries is corrosive. Avoid contact with skin, eyes and clothing. If the battery liquid comes into contact with the skin and eyes, wash the affected area with water and seek medical advice.
In the case of battery liquid leakage, use protective gloves and clean the battery compartment with a dry cloth. Dispose of the materials used for cleaning.
PRECAUTIONS
Take the following precautions to avoid minor or moderate injury and damage to your device:
- Do Not Use this device if your skin is sensitive to mouthpiece and masks.
- Do Not Allow service or maintenance the equipment while used in patients.
- The patient is an intended operator and can perform the maintenance the equipment.
- If any operator requests more information such as circuit diagrams, parts list and product descriptions, for repairs carried out by qualified technical personnel, please contact the manufacturer. If there is any emergency, move the device off you first and then shut it off and contact the local dealer.
- Do Not Use if any of the following conditions apply to you:
- *You have an active skin condition in the treatment area including, sores,
- *psoriasis, eczema, sunburns, herpes simples, open wounds or a rash.
- *You have any other conditions which is in your doctor’s opinion would make it
- *unsafe for you to be treated.
- *Keep this device out of reach of children.
- *If you are not sure if the device is safe for you, please consult your doctor.
WARNINGS ON ELECTROMAGNETIC COMPATIBILITY
- The appliance is suitable for use in any environment indicated in these instructions for use, including domestic environments.
- Under certain circumstances, in the presence of strong electromagnetic disturbance, use of the appliance may be subject to limitations.
- Do not use this appliance in the immediate vicinity of other electrical appliances, as this could cause a malfunction.
- Failure to comply with these notes could be detrimental to the performance of theappliance.
- Mobile telephones or appliances that generate electromagnetic fields must not be used in the vicinity of theproduct.
- Do NOT use the product in environments subject to strong electromagnetic interference.
- Keep the device at least 3.5 metres from other electrical products with an energy consumption higher than 2 W, in order to avoid electromagnetic interference.
Additional quantitative data regarding electromagnetic compatibility are available from Naweti and can be obtained upon request.
PACKAGE CONTENTS
- Main unit Medicinal productreservoir
- Accessories (child mask, adult mask, mouthpiece)
- Waterproof bag
- USB Type C Cable
- These instructions for use
Appliance functions
This device complies with IEC 60601-1-11 standards and is designed for the
treatment of respiratory disease and the prevention ofrespiratory tract
infections. It canbe used in the treatment of respiratory tract conditions,
such as colds, fever,bronchitis, asthma, pneumonia, pulmonary mycosis and
cardiopulmonary disease. The exact therapy to be administered must be
prescribed by a medical practitioner.
This appliance is based on a technology that uses the oscillation of the
piezoelectric crystal inside it to transform medicinal products for inhalation
into micro droplets of liquid. These micro droplets are able to penetrate deep
into the upper and lower airways, to carry the active substances to the right
places in a targeted manner.
The nebulisationspeedhasbeen studiedtoguarantee maximum effectivenessfrom
treatment and is calibrated to adapt to use by both adults and children.
Appliance characteristics
- Portable device providing high-efficiency nebulisation.
- Silent operation with noise levels of under 25 db during nebulisation. Finely nebulised particles.
- Provided with a liquid level sensor that stops the device when the medicinal product reservoir is empty.
- Choice of power supply: USB Type C Cable (provided).
DESCRIPTION OF THE APPLIANCE
1. Medicine cup 2. Mesh atomizer 3. on/off button 4. Apparatus body 5. Snap-
Fit
6. Type C interface 7. Battery cover(unopen)
8. USB Type C Cable 9. Child mask 10. Adult mask 11. Mouthpiece
12. AA Batteries (not included) 13. power indicator light 14. run indicator
light
INDAICATOR LIGHT & OPERATION DESCRIPTION
-
Run indicator light:
Atomization mode: green light breathing.
Cleaning mode: blue light breathing.
Water shortage: turn off after the blue light flashes for 4 times. -
Power indicator light:
Charging: blue light flashes.
Full: blue light on. -
operation description (Atomization rate adjusted: Yes):
In the shutdown state, press the on/off button key to start atomization.
In the atomization mode, press the on/off button to Change the atomization rate.
-Judging the fogging rate according to the speed of the flashing light, when the light flashes quickly indicates that the fogging rate is fast; the light flashes slowly indicates that the fogging rate is slow.
-There are three levels of atomization rate.
In the atomization mode, press and hold the on/off button to shut down.
In the shutdown state, press and hold the on/off button to start cleaning mode.
APPLIANCE PREPARATION
This nebuliser can operate either on the USB Type C cable (provided) connected to a power supply unit (not provided). The power supply unit must satisfy the following parameters:
- input voltage: 100-240 V AC, 50/60 Hz;
- output voltage: 3-5 V DC,1-2 A;
-
Use with the Type C cable provided
This appliance can be operated using the Type C cable provided.
• Connect the type-c cable to the atomizer charging port.
• connect the cable to thesocket;
• connect the cable to the power supply unit (not provided).
Note: Check that the output port of the power supply unit matches the AC power supply required.
To guarantee safe use, use a power supply unit that meets electrical safety standard IEC 60601-1. -
Before using the unit for the first time.
Notes
• The atomizer and accessories must be cleaned and disinfected before they are used for the first time. For information about this, see “CLEANING and MAINTENANCE”.
• Parts (child mask, adult mask and mouthpiece) in contact with human body should only be used by the same person to prevent cross infection.
• Spraying becomes much less effective when the batteries are weak. -
Assembly of the nubulizer
• Remove the unit from the packaging.
• Fit the medicine cup onto the apparatus body. (image1)
• 3.When remove the medicine cup, please press the Snap-Fit down in the direction of the arrow in image 2, and push the medicine cup to avoid damage to the nebulizer. (image 2). -
Operating the device with the A/C Adapter
• Insert the type-c cable into the type-c interface.
• Connect the type-c cable to the power adapter.
• Plug adapter the A/C outlet.
INSTRUCTION FOR USE
-
Preparing the nebulizer
• For reasons of hygiene, it is imperative that the nebulizer and accompanying accessories are cleaned and disinfected after every use.
• If the therapy requires that various different medicines be inhaled in succession, ensure that the medicine cup is rinsed after every use. -
Filling the nebulizer
• Open the medicine cup by opening the clip, and fill the medicine cup with normal saline or medicine. Do not overfill the container. The maximum recommended fill amount is 8ml. (image 5)
• Use medication only on the advice of a physician, and check the appropriate inhalation duration and quantity for your needs. -
Closing thereservoir
• Close the lid of the medicine cup and lock the clip in place.
•Do not shake the nebuliser or turn it upside-down, which could cause spillage of the medicinal product. -
Fitting theaccessories
• Fit the appliance with the appropriate accessory: use the mouthpiece for treatments to be administered to the throat, and the child or adult masks for treatments to be administe-red through the nasal cavity or to the throat (image 6).
• Hold the appliance up to the mouth and place the lips tightly around the mouthpiece.
• When using the mask, place it over the nose and mouth, without covering the eyes.
• Start the appliance by pressing the ON/ OFF button. If the device is working correctly, the green indicator light will come on and nebulised medicinal product will be released from the appliance. -
Indications for correct inhalation
• During the treatment, you should be calm, relaxed and seated, holding the nebuliser in one hand.
• Takeslow, deepbreaths toallowthe particles to distributeeffectively.
• When using the mouthpiece,taketheflat end of the mouthpiece to the mouth and close the lips slightly to allow the medicinal product to reach the desired area.
• When using the mask, hold it up to the face to cover the nose and mouth. For treatment via the nasal cavity, breathe in through the nose and out through the mouth. For treatment via the throat, breathe in through the mouth and out through the nose.
•After assembly and before use, pour sterile saline solution or deionised water into the medicinal product vessel and press On/Off to check it is working correctly.
•To use the mouthpiece correctly, the liquid should not be directed towards the tongue.
•Do not swallow the liquid, make sure it reaches the intended area.
•Breathe regularly and without sudden movements to avoid potential obstructions.
•The nebuliser will not operate if the medicinal product vessel is empty. Tilt the mainunit slightly towards you to wet the vibrating mesh with the medicinal product.
•Nebulisation will only occur if the vibration device is immersed in the medicinal product.
•When the medicinal product level is low, tilt the device towards you from the On/Off side and collect the medicinal product that has accumulated on the plate to use all the residual product.
•The device must be protected against blows, as they could break the plate.
•Do not shake the device violently during use, otherwise it will switch off automatically.
•The device may not be used with hard water, as it could damage the appliance.
•This device cannot be removed from the battery, otherwise it will not continue to be used. -
After treatment
• At the end of the treatment, switch the applianceoffusingtheON/OFFswitch. The green power indicator light will switchoff.
• The appliance is provided with a liquid level sensor that stops the device when the medicinal product reservoir is empty. For technical reasons, a very small amount of product will be left in the reservoir and must be disposed of before putting the device away. Make sure that there are no batteries in the device during use.
• When using the portable battery charger/power supply unit, remove the plug from the mains socket after use.
• The medicine cup and accessories (child mask, adult mask and mouthpiece) must be cleaned after use. For information, see “Cleaning and MAINTENANCE”. -
Dismantling the appliance
• Remove the mouthpiece ormask.
• Holding the main unit in one hand, press the button on the rear.
• Holding the medicinal product vessel in the other hand and remove the medicinal product reservoir from its recess by sliding it forwards.
• Open the lid, dispose of the residual medicinal product, then clean the device and leave the various parts to dry. Store the device in a clean, well- aired and dry place.
• For further details, see the “Cleaning and MAINTENANCE” section.
CLEANING and MAINTENANCE
To guarantee correct device operation, it is important to ensure that the Cleaning operations described below are carried out carefully. Otherwise, the device might not dispense the medicinal product the next time it is used, or the medicinal product might bedispensed,but very slowly andnot at theideal speed.
Remember to turn off the device after use.
Make sure the device is switched off after use.
After each use, discard the leftover medicinal product and remove the
accessory from the main unit in order to clean it thoroughly .Dry the parts
immediately after washing.
Do not stow away the main unit, medicinal product vessel or other accessories
when wet or damp.
Observe the following hygiene instructions in order to avoid any health risks.
The nebulizer and accessories are intended for multiple use. Please note that
cleaning and hygienic reconditioning requirements differ according to the
different areas of application.
Parts (child mask, adult mask and mouthpiece) in contact with human body
should only be used by the same person to prevent cross infection.
Cleaning and sanitising the medicinal product reservoir
- Remove the mouthpiece and any accessories from the atomizer.
- Open the vessel and discard any leftover medicinal product.
- Pour a small amount of hot distilled water (30-60°C) into the vessel and close the lid.
- Press press and hold the on/off button for 5 seconds to start cleaning mode, the blue power indicator light will come on.
- Switch the device on in cleaning mode to nebulise the distilled water for 1-2 minutes in order to eliminate the residual medicinal product. The cleaning mode stops automatically after 3 minutes.
- Rinse the vessel and lid with distilled water. Carefully remove any excess water with a clean, soft cloth or leave the parts to dry naturally in a clean place.
- Use medical gauze or cotton buds for cleaning and disinfecting operations.
- Use medical gauze or cotton buds for cleaning and disinfecting operations.
- Do not rub with paper or other cloths, to avoid compromising the correct operation of the appliance.
- Do not clean using sharp objects or touch the mesh.
- Do not use household bleach or other aggressive substances to clean the device, only the solution indicated above is allowed.
Cleaning and sanitising the main unit
- Carefully clean the main unit using a 75% rubbing alcohol solution and remove any excess with a clean, softcloth.
- Clean the electrodes connecting the main unit and the medicinal product vessel using the procedure indicated above.
Do not clean the main unit using volatile liquids such as petrol or diluents.
Do not rinse the main unit or immerse it in any liquid.
Cleaning and sanitising the mouthpiece and masks
- Remove the medicine cup, mouthpiece or mask.
- Rinse the medicinecup, mouthpiece and mask with de-mineralised water alone for 2-3 minutes (water temperature ≤50 °C).
- Dry well using medical gauze.
- Immerse the mask and mouthpiece in a 75% rubbing alcohol solution for at least 3 minutes to disinfect them and leave to dry naturally.
- Store the appliance in the carry case provided, when not in use.
Notes
- The cleaning mode is very important and must be completed, otherwise the atomizer will be blocked and cannot be used normally.
- Do not put pressure on the mesh with brushes or similar, as this may easily puncture the mesh causing irreparable damage, and will void the warranty. The metal is very thin and can be punctured easily.
- If any traces of medical solutions or impurities remain on the metal contacts on the device and atomizer, use cotton buds to remove them.
- Clean accessories & Medicine cup
- Remove the medicine cup and accessories (child mask, adult mask or mouthpiece) from the nebulizer. Clean with purified water.
- Please be careful not to use fast charging adapter for charging! Due to the circuit board chip charging input is 0.3V-6V more than 6V will trigger the chip protection, the use of the recommended adapter to use is 5V output.
–The atomizer has overcharge protection, overdischarge protection and overcurrent.
–Overcharge protection is the battery voltage to 4.3V is the battery full state will automatically disconnect charging protection.
–Over-discharge protection: is the battery discharge to 2.3V is the lowest power state, the battery is automatically disconnected protection.
–Over-current: that is, the charging line should not exceed 3A output input current. Now on the market are 1A-2A more basic general purpose!
TROUBLE-SHOOTING
In the event of problems during use of the appliance, consult the information below.
Problem | Possible causes | Solution |
---|---|---|
The device is on but nebulizes weakly | The medicine bottle is not properly | |
installed. | Make sure the medicine bottle is properly installed. | |
The medicine bottle is not clean. | Clean the medicine bottle. | |
The medicinal product level is low. | Tilt the main unit slightly towardsyou, |
otherwise add medicinal product.
The power indicator flashes for 1 second and then turns off| The medicine
bottle is not properly installed.| Make sure the medicine bottle is properly
installed.
Insufficient medicine in the nebulizer or no medicine was loaded.| Fill the
medicine bottle with the proper amount of medicinalproduct.
The medicine bottle is not clean.| Clean the medicine bottle.
The medicinal product level is low.| Tilt the main unit slightly towardsyou,
otherwise add
medicinal product.
The power indicator does not light, and the device not nebulize| The
batteries have not been inserted properly.| Insert the batteries correctly.
The medicine used is unsuitable for spraying (e.g. too thick, viscosity must
be less than 3)| Add normal saline to dilute. Always follow the instructions
of your physician.
Batteries are exhausted.| Replace the new batteries.
The run indicator light is not on, and the atomizer is not sprayed.| The
positive and negative directions of the battery are reversed. (AA battery
type)| Make sure the battery is installed correctly.
The battery runs out. Or the power adapter (to be purchased by the user) is
not properly connected to the atomizer.| Replace the battery with a new one
(AA battery type) or charging (Lithium battery type only). Reconnect the
power adapter properly.
Restart the machine.
Once turned on, the device switches off after a fiew seconds| The medicinal
product level is low.| Tilt the main unit slightly towardsyou, otherwise add
medicinal product.
| The medicine bottle is not clean.| Clean the medicine bottle.
The device automatically shuts down in use| The medicine bottle is not
properly installed.| Make sure the medicine bottle is properly installed.
Medicine is running out but the device cannot automatically power off| There
is no medicinal product in the bottle.| Fill the medicine bottle with the
proper amount of medicinalproduct.
The medicine bottle is not clean.| Clean the medicine bottle.
The Medicine of medicine bottle is leaking| Certain medicines may produce
some foam in the medicine bottle.| Press the START/STOP button to turn the
device off,
and clean the foam.
The medicine bottle is not clean.| Clean the medicine bottle.
Medicine bottle is broken or damaged.| Replace the medicine bottle before
using the device again.
DISPOSAL
The product packaging is made of recyclable materials. It must be disposed of in compliance with environmental regulations.
For environmental reasons, the appliance must not be discarded with normal
household waste at the end of its service life.
It must be taken to an appropriate disposal facility. Dispose of the appliance
in accordance with European Directive 2012/19/EU regarding waste electrical
and electronic equipment (WEEE). For further information or clarification,
contact the local authority responsible for waste disposal.
PRODUCT SPECIFICATIONS
Product name: Portable Rechargeable Nebulizer
Model: WH202AE
Battery type: Charging with type-c cable(Built-in lithium battery)
Atomization rate adjusted: Yes:
Product dimensions: 64x46x98 mm
Weight: approximately 98 g
Capacity: max. 8 ml
Median particle size of atomized particles: 3.0μm±25%
Atomized particles not less than 4μm:≥80%
Nebulization rate
-Strong mode: ≥ 0.3 ml/min (Green light flashes rapidly)
-Mild mode: ≥ 0.15 ml/min (Green light blinks slowly)
-Mild mode: ≥ 0.15 ml/min
Vibration frequency: 120 kHz ±10%
Working noise: ≤ 25 dB
Working conditions:
– Temperature: 5.0 °C ~ 40.0°C
– Relative humidity range:15% ~ 93%
– Atmospheric pression: 86kPa ~106kPa
Conditions for storage and transportations:
– Temperature: -40°C -55°C
– Relative humidity range: 15% ~ 93%
– Atmospheric pression: 70.0 ~ 106.0 kPa
U.S. chips, designed in the U.S. and assembled in China.
AFTER-SALES SERVICE AND WARRANTY
Thisappliance isintendedfordomesticuseonly andis notsuitableforprofessional purposes.
- The warranty covers production defects only and is not valid for damage caused by accidents, incorrect use, negligence or improper use of the product.
- The appliance must not be opened under any circumstance; the warranty is not valid if the product has been opened or tampered with.
- If the product fails, please send an email to Naweti-Service@hotmail.com. We will provide corresponding solutions to the product problem
- The manufacturer declines all responsibility for any damage/injury that may be directly or indirectly caused to people, property or domestic animals as a consequence of failure to comply with the indications provided in this instruction manual, in parti- cular the warnings regarding the installation, use and maintenance of the appliance.
- Given its on-going commitment to improving its products, Naweti reserves the right to modify all or parts of its products in order to meet production requirements, without giving advanced notice, without this entailing any responsibility for Naweti or its dealers.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>