nauticam N120 Flat Port 27 For Canon Camera Instruction Manual
- May 15, 2024
- nauticam
Table of Contents
INSTRUCTION MANUAL
for N120 Flat Port 27 (with bayonet mount)
PN# 18709
N120 Flat Port 27 For Canon Camera
FORWORD
Thank you for your purchase of a NAUTICAM product.
At NAUTICAM, we pride ourselves in the ability to recognize the requirements
of professional as well as amateur underwater photographers and fulfill them
through the innovative designs of our products. We strive to achieve a high
level of userfriendliness by allowing stress-free installation and easy
operation of all important functions of the camera.
Each product is individually inspected and water pressure tested to ensure
optimum quality.
Please read this manual carefully before using the product, this will maximize
its performance as well as its lifetime.
PRECAUTIONS
- After installation of the port combo, please make sure the O-ring (s) are free from debris and uneven surface issues.
- A water-tight/vacuum test without the camera inside the housing is highly recommended after the changing of port and O-ring(s).
- Do not use lubricants from other brands with the silicone rubber O-ring on this housing, only use the lubricant provided by NAUTICAM.
- Discontinue use immediately should you notice any leakage.
- Do not open the product in a wet or sandy environment. Protect the interior from moisture and debris in order to prevent malfunction or leakage.
- Defective products should be shipped to our distributors for service, unauthorized disassembling and/or modifications could result in malfunction or leakage.
- When travelling by air, do not travel with any port installed as this may lead to a pressure difference between the atmosphere and inside the housing.
All NAUTICAM Products are warranted against any material and manufacturing
defects for two years from the date of purchase for consumer use. This
warranty only applies to products purchased from authorized NAUTICAM dealers
and does not extend beyond the original retail purchaser.
To return your product for service, please contact your regional authorized
service center(s). Please note that this warranty only applies when the
product is purchased in the territory where the service center is located.
NAUTICAM does not hold responsibility for damage, of any nature, to any
equipment used with and/or placed within our products.
NAUTICAM accepts no liability for any loss of captured images or the inability
to capture images even if it is due to the malfunctioning of our products.
Unauthorized modifications and/or repairs of our products will automatically
invalidate the warranty.
PACKAGE CONTENTS
- Make sure that you have all the included items listed below before using this product.
- If some items are missing or damaged, please contact us or the local Nauticam dealer.
IDENTIFICATION OF PARTS
Preparation of the product
- After verifying that the sealing O-ring is in good condition, lightly coat it with the lubricant provided and wipe away the excess.
- Make sure the O-ring groove is free from any foreign material; the groove can be cleaned with the aid of a microfiber cloth.
- Carefully place the port O-ring into the groove, ensuring that it lays flat and inside the entire groove.
- Inspect the O-ring again, make sure there is no foreign materials.
- After installing the port, lift up the entire system and inspect where the housing back and port meet the housing. There should be a thin, uniform gap with no extruded Oring.
MOUNT PORT TO HOUSING
-
Push the safety button of the port locking lever downwards.
-
Turn the port locking lever to the release position as shown.
-
Lift the housing cap.
-
Align the mounting indices of the port and the housing, these appear as white circles on both the port and the housing.
Gently push the port into the opening of the housing, until it cannot go in any further. -
Lock the port into place by turning the port locking lever to the inward position.
To ensure that the port is securely mounted, confirm that the green line on the safety button of the port locking lever is visible.
To remove the port from the housing, simply turn the port locking lever to the outward position and gently pull it out.
SPECIFICATIONS
18709 N120 Flat Port 27 (with bayonet mount)
Dimensions: | DAI132.0× 56.9 |
---|---|
Port Opening: | N120 |
Port Mount: | Bayonet Mount |
Compatible Lens | Canon RF 24-50mm F4.5-6.3 IS STM |
Remark:
Nauticam supports only e-manuals. Please download corresponding product
manuals on google drive https://bit.ly/Nauticammanual, or contact us for
emanuals.
CARE AND MAINTENANCE
- Soak the housing system in fresh water after each use, during which all control buttons/knobs should be operated a few times to avoid the accumulation of salt residue; wipe the housing with a towel before opening.
- After removing the housing from the rinse tank, carefully press the housing lock safety button for a few times to avoid the accumulation of salt residue.
- After each day of diving, it is advisable to have both the housing main O-ring and port O-ring removed from its groove with the O-ring remover and inspected for damage. Also check that the O-ring retains its original circular shape; never stretch the O-ring excessively or remove it with a sharp object. The O-ring groove should be cleaned to ensure it is free from any salt deposit or foreign material; lightly coat the O-ring with the provided lubricant before reinstalling it in the groove. A damaged O-ring should be discarded immediately and replaced only with one that is provided by NAUTICAM.
Please refer to “Nauticam Product Care and Maintenance Guide” for more details.
References
- Instruction Manual - Google Drive
- web.wechat.com/cgi-bin/mmwebwx-bin/webwxcheckurl?requrl=Nauticam.com&skey=@crypt_c6bb4bff_63df5f91bf17e41c65dcf6dbb80406f6&deviceid=e249347269776799&pass_ticket=ybEnCg9nmKAYQ4eeF6WAlv/XL5bJQlEP/Nds6iEn7EOeNLfT24kRxfC4Jt7EOc38&opcode=2&scene=