LIGHTWARE PSU2x10-200-12V Rack Mountable Power Supply
Specifications
- General Compliance: CE, UKCA
- EMC (Emission): EN 55032:2015+A1:2020
- EMC (Immunity): EN 55035:2017+A11:2020
- Electrical safety: EN 62368-1:2020
- RoHS compliance: EN 63000:2018
Product Information
Box Contents
- Power supply unit with rack ears (2x)
- IEC power cable
- Safety and Warranty Info, Quick Start Guide
Front and Rear View
- Power LED lights green when the unit is powered on.
- Standard IEC power connector. Accepts 100 to 240 Volts, 50 or 60 Hz power sources.
- Locking DC connectors for the appliances that are desired to supply.
Assembly of the Rack Ears
Two rack ears are supplied with the product, which are fixed on the left and right side with 8 pcs M4 screws. The ears are removable and can be re- assembled to another position or direction.M4x8 size is the longest allowed screw for fixing the ears to the housing.
Product Usage Instructions
Powering On/Off
The power supply can be switched ON/OFF using the power switch located on the AC connector. The Power LED will light up green when the unit is powered on.
Connecting DC Cables
Use locking DC connectors provided with the product for a robust and safe power connection. Turn the locking DC connector clockwise to establish a secure connection.
Compatibility
Refer to the compatibility table provided in the manual for Lightware products compatible with the power supplies and technical data of the DC plug.
FAQ
-
Q: Are DC-DC power cables included in the box?
A: No, DC-DC power cables are not supplied with the product. -
Q: What is the main difference among the variants of the product?
A: The main differences among the variants are the number of DC connectors and the voltage range. PSUx20-400-12V can be seen in the photos. -
Q: How do I disconnect the cable from the locking DC connector?
A: Before trying to disconnect the cable, remember to turn the plug counterclockwise.
Quick Start Guide
- PSU2x10-200-12V
- PSU2x10-200-5V
- PSU2x20-400-12V
- PSU2x20-400-5V
Front and Rear View
- Power LED Power LED lights green when the unit is powered on.
- AC connector Standard IEC power connector. Accepts 100 to 240 Volts, 50 or 60 Hz power sources.
- Power switch The power supply can be switched ON/OFF with this switch.
- DC connectors Locking DC connectors for the appliances that are desired to supply
The main differences among the variants are the number of the DC connectors and the voltage range; PSUx20-400-12V can be seen on the photos.
Introduction
Thank you for choosing Lightware’s rack mountable power supply. The units are
all housed in a 1U high solid metal rack enclosure for durability and easier
mounting. 5V and 12V DC output versions are also available with 10 and 20
output connectors. Several protections are built in like short circuit,
overload, over voltage, over temperature which features make these PSUs
trustful. The units are designed to supply devices made by Lightware.
The cover picture of this document is an illustration. The PSU2x series
devices are built with 2 pcs rack ears on the front side by default.
Box Contents
Please note that DC-DC power cables are not supplied with the product.
Connecting Devices
- Place the power supply unit in the rack and fix it by screws with the mounting ears.
- Connect the DC cables to the power supply and to the extender units.
- Connect the AC power cable to the power supply.
- Switch on the appliance.
Please note that fixing screws and DC power cables are not supplied with the
appliance.
If the power supply cannot be switched on, please check the IEC power cable,
the AC mains and the fuse at the AC connector on the back of the unit. If the
LED on the front panel does not light up at all, the unit is most likely
damaged and further use is not advised. Please contact
support@lightware.com.
Locking DC Connectors
DC cables from Lightware contain locking DC connector that establishes robust
and safe power connection. After plugging it in, turn the plug clockwise as
shown on the picture
Do not forget to turn the plug counterclockwise before trying to disconnect
the cable.
Assembly of the Rack Ears
Two rack ears are supplied with the product, which are fixed on the left and
right side with 8 pcs M4 screws. The ears are removable and can be re-
assembled to another position or direction.
M4x8 size is the longest allowed screw for fixing the ears to the housing.
Using different (e.g. longer) screws may cause damage to the device
.
Specifications
- General
- Compliance………………………………………………………………………………………..CE, UKCA
- EMC (Emission)…………………………………………………………….EN 55032:2015+A1:2020
- EMC (Immunity)…………………………………………………………..EN 55035:2017+A11:2020
- Electrical safety……………………………………………………………………….. EN 62368-1:2020
- RoHS compliance………………………………………………………………………..EN 63000:2018
- Warranty………………………………………………………………………………………………..3 years
- Operating temperature………………………………………………. 0 to +55°C (+32 to +122°F)
- Operating humidity…………………………………………………. 10% to 90%, non-condensing
- Cooling………………………… Fan (2 pcs., 40 mm diam.), air flows right to left (front view)
- Protection against…………… Short circuit / Overload / Over voltage / Over temperature
- Connectors
- AC power connector……………………………………………………………… IEC C14 receptacle
- DC power connector (5V version)………………………. locking DC connector, 2.5/5.5 mm
- DC power connector (12V version)…………………….. locking DC connector, 2.1/5.5 mm
- Power
- Power supply option………………………………………………………………………….built-in PSU
- Supported power source………………………………………………….100-240 V AC; 50/60 Hz
- AC fuse……………………………………………………………………………………………………..F 5 A
Models| PSU2x10- 200-5V| PSU2x20- 400-5V| PSU2x10- 200-12V| PSU2x20- 400-12V
---|---|---|---|---
DC output number| 10| 20| 10| 20
Nominal power| 200 W| 400 W| 200 W| 400 W
DC output voltage| 5V| 12V
Rated current per output port| 2.5A| 1.1A
Heat dissipation (max.)| 683| 1365| 683| 1365
- Enclosure
- Rack mountable……………………………………………………………………………… Yes, 1U high
- Enclosure material…………………………………………………………………………….. 1 mm steel
- Dimensions in mm…………………………………………………… 482* (446)W x 182D x 43.9H
- Dimensions in inch……………………………………………………… 19* (17.6)W x 7.2D x 1.8H
- Net Weight (PSU2x10-200 series)………………………………………………..2870 g / product
- Net Weight (PSU2x20-400 series)………………………………………………..3430 g / product
with rack ears
Compatibility
The following table contains those Lightware products that are compatible with the power supplies and also the technical data of the DC plug:
PSU2x10-200-5V, PSU2x20-400- 5V
DC plug| Compatible Lightware products
Power supply| Device| Type
2.5 / 5.5 mm
| 1.35 / 3.5 mm| DVI-OPT-110 series DP-OPT 150 series
USB Micro-B| DVI-HDCP-OPTS 90 series
DVI-HDCP-OPTM 90 series
2.5 / 5.5 mm
| EDID Manager V4
HDMI-, DVISL- and DVIDL extenders
DA2DVI-HDCP-Pro
DA2DVI-DL
DA2HDMI 4K-Plus series
DP-OPT 100 series DVI-TP series
HDMI-, UMX- and DVIDL-OPT series
HDMI 4K series
SW4-OPT-TX240RAK
Remote control panels
PSU2x10-200-12V, PSU2x20-400- 12V
DC plug| Compatible Lightware products
Power supply| Device| Type
2.1 / 5.5 mm
|
2.1 / 5.5 mm
| DP-TPS-200 series
DVI-HDCP-TP-50 and -100 series DVI-HDCP-TPS-90 and -210 series HDMI-TPS-TX-200 series
HDMI-TPS-90-95-97 series HDMI-TPS-RX110AY
HDMI-TP-50, -100 and -200 series UMX-TP series
UMX-TPS-TX100 series TPS-TX200 series MMX4x2-HT200 MMX4x2-HDMI
SW4-TPS-TX240
Cables are available at Lightware, please contact sales@lightware.com.
Mounting with Rack Ears
The rack ears allow mounting the device as a standard rack unit installation
.
Always use all the four screws for fixing the device ears to the rack rail.
Choose properly sized screws for mounting. Keep a minimum of two threads left
after the nut screw.
Ventilation
To ensure the correct ventilation and avoid overheating, leave enough free
space around the appliance. Do not cover the appliance, leave the ventilation
holes free on both sides.
Mechanical Drawings
The PSU2x20-400-12V model can be seen in the pictures, but the dimensions are the same for both models. Dimensions are in mm.
Front View (1:3)
Rear View (1:3)
Top View (1:3)
Side View (1:1)
Important Safety Instructions
Please read and keep the information in the attached safety instructions supplied with the product before starting to use the device
Class I Apparatus Construction
- This equipment must be used with a mains power system with a protective earth connection.
- The third (earth) pin is a safety feature, do not bypass or disable it. The equipment should be operated only from the power source indicated on the product.
- To disconnect the equipment safely from power, remove the power cord from the rear of the equipment or the power source. The mains plug is used as the disconnect device, the disconnect device shall remain readily operable.
- There are no user-serviceable parts inside of the unit. Removal of the cover will expose dangerous voltages. To avoid personal injury, do not remove the cover. Do not operate the unit without the cover installed.
- The appliance must be safely connected to multimedia systems. Follow the instructions described in this manual.
Replacing the AC Fuse
Unplug the AC power cord from the device. Locate the AC fuse on the rear
panel. Replace only the AC fuse as indicated on the rear panel. Connect the
power cord to the device and to the AC power source. Make sure the device is
working properly.
Ventilation
For the correct ventilation and to avoid overheating, ensure enough free space
around the appliance. Do not cover the appliance, leave the ventilation holes
free, and never block or bypass the ventilators (if there are any).
WARNING
To prevent injury, the apparatus is recommended to be securely attached to the
floor/wall or mounted by the installation instructions. The apparatus shall
not be exposed to dripping or splashing, and no objects filled with liquids,
such as vases, shall be placed on the apparatus. No naked flame sources, such
as lit candles, should be placed on the apparatus.
WEEE ( Waste Electrical & Electronic Equipment )
Correct Disposal of This Product
- This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of waste and recycle it responsibly to promote the sustainable reuse of material resources.
- Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling.
- Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
Schematic of PSUx10-200-5V and PSUx-10-200-12V
If any of the DC connectors gets faulty, the other DC connectors will be usable due to the design of the appliance. Do not use the faulted connector, please contact support@lightware.com.
Schematic of PSUx20-400-5V and PSUx-20-400-12V
Lightware Visual Engineering PLC.
Budapest, Hungary
sales@lightware.com
+36 1 255 3800
support@lightware.com
+36 1 255 3810
©2023 Lightware Visual Engineering. All rights reserved. All trademarks
mentioned are the property of their respective owners. Specifications are
subject to change without notice.
Further information on the device is available at
www.lightware.com.
Doc. ver.: 1.6
19210107
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>