LIGHTWARE UBEX-PRO20-HDMI-F100 UBEX F Series Endpoint Device User Guide
- June 4, 2024
- LIGHTWARE
Table of Contents
Quick Start Guide
-PRO20-HDMI-F100
-PRO20-HDMI-F110
-PRO20-HDMI-F120
Important Safety Instructions
Please read the supplied safety instruction document before using the product
and keep it
available for future reference.
The extender is a Class 1 laser product.
Introduction
Thank you for choosing the Lightware UBEX F-series endpoint device. UBEX
(Ultra Bandwidth Extender) product family offers a new optical solution
allowing 4K@60Hz 4:4:4 uncompressed signal extension with extra low latency
for the users. We use packet-based transmission instead of the conventional
method.
We use standard, certificated 10 Gbps SFP+ optical modules which are plug and play, so they are interchangeable by the user. There could be either duplex multimode/single mode modules (1–1 fiber for each direction per 10 Gbps link) or bidirectional Singlemode modules (1 fiber for both directions per 10 Gbps link). The maximum supported cable length is 400 m with multimode modules (OM4), 10 km with short-range Singlemode modules, or 80 km with long-range single-mode modules. In a typical application with a standard, non-blocking 10 Gbps Ethernet switch it is necessary to use both directions of the link. Therefore the number of necessary fibers depends on the link speed and the optical module: for 10 Gbps 1 or 2 fibers, for 20 Gbps 2 or 4 fibers are needed. One of the primary advantages of the new architecture is scalability.
Box Contents
- Only for UBEX-PRO20-HDMI-F110 and UBEX-PRO20-HDMI-F120 models.
|
---|---
1| Status LEDs| The LEDs give immediate feedback about the current status of
the extender.
---|---|---
2| LCD screen| LCD screen showing the most important settings and parameters
in the front panel menu.
3| Jog dial
control knob| Easy setting and menu navigation by the jog dial control. Turn
and click the knob while getting feedback on the LCD.
4| Reset button| Reboots the device (the same as disconnecting from the power
source and reconnecting again).
5| AC connector| Standard IEC connector accepting 100-240 V, 50 or 60 Hz.
6| Ethernet connectors| Standard locking RJ45 connectors for 1 Gbps Ethernet
connections to control the device, for user Ethernet access, and for firmware
upgrade purposes. The F100 model is built with 2x RJ45 connectors, F110 and
F120 models are built with 3x RJ45 connectors.
7| HDMI input ports| HDMI input ports with HDMI 2.0 support for source
devices.
8| HDMI output ports| HDMI output ports with HDMI 2.0 support for sink
devices.
When the device is configured as a transmitter, the ports operate as local
HDMI outputs.
9| SFP+ port
slots| Optical port slots for two 10 GbE SFP+ modules or DAC cables. Ports can
be used for either single mode or multimode optical connections.
10| USB B-type
connector| USB connection to host (computer) unit via USB B-type connector.
11| USB A-type
connectors| USB KVM ports for HID-compatible devices (preferably keyboard and
mouse).
12| Audio input
port| 5-pole Phoenix connector for balanced analog audio input. The port is
available in all operation modes (TX/RX/TRX).
13| Audio output
port| 5-pole Phoenix connector for balanced analog audio output. The port is
available in all operation modes (TX/RX/TRX).
14| Infrared
connectors| 2 x 3.5mm jack (TS/TRS) connectors for Infrared units (IR IN for
the detector, IR OUT for the emitter).
15| RS-232
connector| 3-pole Phoenix connector for serial communication.
Front Panel Operation
Navigation in the LCD Menu
The front panel has a color LCD showing the most important settings and
parameters. The jog dial control knob can be used to navigate between the menu
items or change
the value of a parameter (in the case of TX, RX, or TRX as well). The knob can
be pressed to enter a menu or edit/set a parameter.
The LCD Menu in Extender and Matrix Modes
The menu structure is different in Extender and Matrix modes. The following
settings are not available in the LCD menu of the endpoint in Matrix mode but
they can be set in the Matrix Management Unit:
- Video settings – TX/RX/TRX input/output settings
- EDID operations – EDID switching and saving
- Network settings – static and DHCP (dynamic) IP address settings
- Reloading factory default values
The Extender or Matrix mode is set automatically in the endpoint device. If
the device detects a direct connection with another endpoint device on the
other side of the connection, the application mode is set to Extender mode; if
the device is managed by the MMU, the application mode is set to Matrix mode.
Operation Mode Settings (only in Extender Mode)
The operation mode (TX/RX/TRX) of the unit can be changed from the LCD menu in
a few steps.
- Navigate to the System settings / Operation mode / Switch mode… submenu and select the required mode: Transmitter, Receiver or Transceiver.
- After the confirmation the unit resets. After booting up the device operates in the desired mode.
Set Static IP Address (only in Extender Mode)
The IP address of the endpoint can be set from the front panel:
-
Navigate to the System settings / Network / DHCP menu and check the current state of the DHCP. If the setting is Enabled change it to Disabled. After this navigate to ave and press Enter.
-
Navigate to the System settings / Network / Static IP menu and select the Static IP address, Subnet mask, and Static gateway options. Set the parameters by the front panel
buttons according to your network requirements. -
Navigate to Save and press Enter.
Set Dynamic IP Address (DHCP) (only in Extender Mode)
- Navigate to the System settings / Network / DHCP menu and check the current state of the DHCP. If the setting is Disabled change it to Enabled.
- Navigate to the Save submenu (the last one of the Network menu) and press Enter.
Restore Factory Default Settings
Navigate to the System settings / Factory defaults menu and press Enter. After
the confirmation, the device reboots and the factory default values are
reloaded in the device.
Status LEDs
LIVE | Transmitter I Receiver I Transceiver |
---|---|
blinking | The device is powered and ready to use. |
off | The device is not powered or out of operation. |
STATUS | Transmitter I Receiver I Transceiver |
on | All measured temperature and voltage values are within the limits. |
blinking | The measured temperature or voltage value is out of the limits. |
off | The device is not powered or out of operation. |
LINK OK | Transmitter I Receiver I Transceiver |
on | The connection is established on SFP+ LINK land 2 and Link Aggregation |
is working.
| blinking| The connection is established on SFP+ LINK land 2 and the LACP
detection period is active.
| off| No connection is established on one of the SFP+ links.
MMU AVAILABLE| Transmitter I Receiver I Transceiver
| on| Matrix mode is active; the communication is live between the endpoint
and the Matrix Management Unit (MMU).
| blinking| Matrix mode is active; no communication between the endpoint and
the MMU.
| off| Extender mode is active; another endpoint is connected via the optical
link.
Mounting Options
The device can be mounted in several ways, depending on the application.
Besides using with a rack shelf, a mounting bracket is available, which offers
easy mounting on truss systems with standard clamps or using the unit built
into furniture.
The 1U high rack shelf provides mounting holes for fastening two half-rack-
sized units. Mounting bracket V2 allows mounting the device to any furniture
surface. Fasten the bracket on the side of the unit with the provided screws
and fasten it to a stand/board/furniture. To order mounting accessories please
contact sales@lightware.com.
Mounting with the 1U High Rack Shelf
**** M3x6 size is the longest allowed screw for fixing the accessories to the housing. Using different (e.g. longer) screws may cause damage to the device.
Connecting Steps
Transmitter (TX) Operation Mode
Receiver (RX) Operation Mode
Transceiver (TRX) Operation Mode
The HDMI in 1 port cannot accept AV signal when the device is configured as a transceiver.
Transmitter (TX) Mode
For all models| HDMI in| Connect the UBEX transmitter and the source devices
(e.g. PC, Blu-ray player) using the HDMI input 1 and 2 ports by HDMI cables.
---|---|---
Local HDMI out| Connect the local sink devices (e.g. monitor, 4K TV) to the
HDMI output 1 and 2 ports by HDMI cables. The output ports are local loopback
ports in this case: the same streams received on the input ports are
transmitted forward.
Ethernet| Optionally, connect the UBEX transmitter to a LAN in order to
control the device. User Ethernet is also transmitted over the SFP+ interface
so be sure not to create a network loop!
Power| Connect the power adaptor to the AC input on the transmitter first,
then to the AC power socket.
For F110/F120 only| Audio in| Connect an audio source (e.g. media player) to
the audio input connector.
Audio out| Connect an audio sink (e.g. active speakers) to the audio output.
RS-232| Optionally for RS-232 extension: connect a controlled unit (e.g. 4K
TV) to the RS-232 port of the device with a serial cable.
For F120 only| USB-B| Optionally for USB HID extension: connect the
transmitter to the computer by the USB-B cable.
USB-A| Optionally for USB HID extension: connect the USB HID devices to the
transmitter (preferably mouse and keyboard).
Receiver (RX) Mode
For all models| Local HDMI in| Connect the UBEX receiver and the local source
devices (e.g. PCs) using the HDMI input 1 and 2 ports by HDMI cables.
---|---|---
HDMI out| Connect the sink devices (e.g. monitor, projector) to the HDMI
output 1 and 2 ports by HDMI cables.
Ethernet| Optionally, connect the UBEX receiver to a LAN in order to control
the device. User Ethernet is also transmitted over the SFP+ interface so be
sure not to create a network loop!
Power| Connect the power adaptor to the AC input on the receiver first, then
to the AC power socket.
Ford F110/F120 only| Audio in| Connect an audio source (e.g. MP3 player) to
the audio input connector.
Audio out| Connect an audio sink (e.g. audio amplifier) to the audio output.
RS-232| Optionally for RS-232 extension: connect a controlled unit (e.g.
projector) to the RS-232 port of the device with a serial cable.
For F120 only| USB-B| Optionally for USB HID extension: connect the receiver
to the computer by the USB-B cable.
USB-A| Optionally for USB HID extension: connect the USB HID devices to the
receiver (preferably mouse and keyboard).
First Steps of Device Configuration
Setting the Operation Mode
All endpoint devices are manufactured as transmitters (TX) by default. Set up
the operation mode for the endpoints that are to be used as receivers (RX) or
transceivers (TRX) with the front panel LCD menu.
Connecting to the Devices over LAN
**** Connecting the devices to the network using the factory default network
settings might cause IP address conflict.
Please follow the steps before connecting the endpoint devices to the network:
- Set different static IP addresses or set DHCP (dynamic IP address) on the front panel LCD menu or via the Lightware Device Controller (LDC) software.
- Establish a connection between the endpoint devices over the SFP+ interface.
Transceiver (TRX) Mode
For all models| HDMI in| Connect the UBEX transceiver and source devices (e.g.
PC)using the HDMI input 2 port by an HDMI cable.
---|---|---
HDMI out| Connect a sink device (e.g. 4K TV) to the HDMI output 1 port by an
HDMI cable.
Local HDMI out| Connect a local sink (e.g. monitor) to the HDMI output 2 by an
HDMI cable. The output port is a local loopback port in this case: the same
stream received on the HDMI input 2 port is transmitted forward.
Ethernet| Optionally, connect the UBEX transceiver to a LAN in order to
control the device. User Ethernet is also transmitted over the SFP+ interface
so be sure not to create a network loop!
Power| Connect the power adaptor to the AC input on the transceiver first,
then to the AC power socket.
Ford F110/F120 only| Audio in| Connect an audio source (e.g. media player) to
the audio input connector.
Audio out| Connect an audio sink (e.g. audio amplifier) to the audio output.
RS-232| Optionally for RS-232 extension: connect a controlled unit (e.g. 4K
TV) to the RS-232 port of the device with a serial cable.
For F120 only| USB-B| Optionally for USB HID extension: connect the
transceiver to the computer by the USB-B cable.
USB-A| Optionally for USB HID extension: connect the USB HID devices to the
transceiver (preferably mouse and keyboard).
Cabling of the BiDi SFP+ Modules
In case of using bidirectional (BiDi) SFP+ modules in the UBEX endpoint
devices, please check the wavelength of the INPUT and OUTPUT modules. If the
wavelengths are different,the cabling might be also different and the modules
shall be connected across.
Software Control – Using Lightware Device Controller (LDC)
The device can be controlled from a computer through the Ethernet ports using
Lightware Device Controller. Please download the application form
www.lightware.com, install it on a Windows PC or
a macOS, and establish a connection to the device.
Factory Default Settings
The following settings are applied in the device once the factory default settings are recalled:
GENERAL SETTINGS
System settings
Application mode (Extender I Matrix)| Auto (the endpoint detects automatically
the actual application mode)
Network settings
Static IP address – TX mode| 192.168.0.101
Static IP address – RX mode| 192.168.0.102
Static IP address – TRX mode| 192.168.0.101
Subnet mask| 255.255.255.0
Default gateway| 192.168.0.1
DHCP| Disabled
LW3 protocol command port| 6107
HTTP port| 80
HDMI PORT SETTINGS – TRANSMITTER MODE
HDMI input port properties
Scaler mode – HDMI in 1| Pass-through
FRC mode – HDMI in 2| Pass-through
Color space converter – HDMI in 1 and 2| No conversion
HDCP setting – HDMI in 1 and 2| Enabled
HDMI PORT SETTINGS – TRANSCEIVER MODE
HDMI input 2 port properties
FRC mode| Pass-through
Color space converter| No conversion
HDCP setting| Enabled
HDMI output 1 port properties
Scaler mode| Pass-through
FRC mode| Pass-through
Color space converter| No conversion
liming mode| Free run
HDCP mode| Auto
Extender and Matrix Application Modes
Extender Mode
OPT
DAC| Connect single mode or multimode (depending on the installed SFP+
modules) fiber optical cables or DAC cables between a UBEX transmitter and a
receiver, or two transceiver
devices. The Extender Mode is detected and applied automatically in the device
once the connection is established successfully.
---|---
OPT
DAC| Connect single mode or multimode (depending on the installed SFP+
modules) fiber optical cables or DAC cables between the UBEX
transmitter/receiver/transceiver devices
and the Layer 3 (L3) network switch. Also, connect the Matrix Management Unit
(MMU) to the switch by fiber optical or CATx cable to configure and control
the virtual matrix. The
Matrix Mode has applied automatically in the endpoint devices once the MMU
claims the endpoint.
---|---
Further Information
The User manual of this appliance is available on
www.lightware.com.
See the Downloads section on the dedicated product page.
Contact Us
sales@lightware.com
+36 1 255 3800
support@lightware.com
+36 1 255 3810
Lightware Visual Engineering LLC.
Peterdy 15, Budapest H-1071, Hungary
Doc. ver.: 1.5
19200230
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>