This Cavius carbon monoxide (CO) alarm is designed and tested to detect CO in private homes. It will provide early warning of the presence of CO.

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.

Product Description

Product Description

SAFETY INSTRUCTIONS:

The device comes with a 3V lithium battery. Batteries are to be handled with care and battery powered devices should be kept out of reach of children. Do not try to recharge or burn the batteries.

INFORMATION ABOUT CARBON MONOXIDE:

CO – Carbon monoxide – is known as the “silent killer” because it is odourless, tasteless and colourless.
It can kill in few minutes.This apparatus may not prevent the chronic effects of Carbon Monoxide exposure.

All people are at risk for CO poisoning. Unborn babies, infants, the elderly, and people with chronic heart disease, anemia, or respiratory problems are generally more at risk than others. The apparatus will not fully safeguard individuals at special risks

Breathing CO can cause headache, dizziness, vom- iting, and nausea. If CO levels are high enough, you may become unconscious or die.

TECHNICAL INFORMATION

  • Diameter: 40mm Height: 38mm.
  • Type of alarm: EN 50291-1:2018 type B apparatus with electro-chemical CO sensor.
  • Battery: Powered by a non-replaceable 3V CR123 Lithium battery with 10-year life (included).
  • IMPORTANT: Do not try to replace the battery. Replace the product if the battery fails.
  • Product Life: 10 years after manufacturing date.
  • Working condition: -10 to +400 C, 30 to 95% non-con- densing.
  • Storage/Transport: -20 to +500 C, 10 to 95% noncondensing.
  • Alarm Sound Level: The minimum sound level is 85 dB at 3 meters.

THE BEST AREAS TO INSTALL YOUR CO ALARM

  • Ideally, an apparatus should be installed in every room containing a fuel-burning appliance.
  • Near bedrooms and living areas.
  • On each level of your home.
  • 1 to 3 meter away from all fuel burning appliances.
  • At eye level to allow optimum monitoring of the in dicator lights.
  • Install as High as possible as CO rises when mixed with heat.
  • You can fit on a wall but as high as possible.

Siting of CO alarms

Siting of CO alarms

AREAS WHERE NOT TO INSTALL CO ALARMS

  • In an enclosed space (for example in a cupboard or behind a curtain).
  • Where it can be obstructed (for example by furniture)
  • Directly above a sink.
  • Next to a door or window.
  • Next to an extractor fan.
  • Next to an air vent or other similar ventilation openings.
  • In an area where the temperature may drop below -10 °C or exceed 40 °C.
  • Where dirt and dust may block the sensor.
  • In a damp or humid location.
  • In the immediate vicinity of a cooking appliance.

PLACEMENT

The CO alarm is designed to be installed on the wall or a ceiling.
PLACEMENT

INSTALLING YOUR CO ALARM

CAUTION: This alarm should be installed by a competent person.

The installation of this device should not be used as a substitute for proper installation, use and maintenance of fuel burning appliances, including appropriate ventilation and exhaust systems.

It does not replace a smoke alarm.

Installation with screw and plug:
Detach the alarm from the mounting base by twisting counter clockwise.
Use the mounting base to mark up horizontally the screw holes on the wall.

Mark up screw holes with a pen

Use the enclosed screws and plugs for installation

Attach the alarm by twisting clockwise.

Please note: The label in the product must not be removed as it contains important information regarding the product.

TEST FUNCTION

After installation and at least once per quarter, test your alarm to make sure it is operating correctly.
It is recommended to check visually every week if the green LED flashes correctly (every minute)

When the top button is pressed the alarm sounder will sound, and when the button is released, the alarm will make a self-test of the sensor and battery for approximately 9 seconds. During this delay the three LEDs will be flashed in sequence. The result of the test will be indicated after the test has been completed.

If the test passes, the green LED will emit for 3 sec.
If the test fails, a fault indication will be given (See section 7).

After the test function is performed, the alarm will need to recover for one minute before the next test can be done (to allow the sensor chamber to re- settle after the test current is applied).

The alarm will also do a self-test every 24 hour and test the sensor for faulty sensor, drift or short circuit.

TIP: It is safe to cover the sound output hole with your finger during the testing to minimize the sound level emitted.

FAULT WARNINGS

Battery fault: Battery low condition is indicated by a very short tone burst “beep” every 60 seconds with yellow LED flashing. Your CO alarm battery is low voltage.

Sensor fault: Sensor fault is indicated by two very short tone burst “beeps” every 60 seconds with yellow LED flashing. Your CO alarm will not respond to CO.

End of life: End of sensor life is indicated by three very short tone burst “beeps” every 60 seconds with yellow LED flashing. Your CO alarm needs to be replaced.

OTHER INFORMATION

Do not paint the alarm.

Disposal: Please dispose the product properly at the end of life. This is electronic waste which should be handled properly.

WARNING: Batteries shall not be exposed to excessive heat such as shine, fire, or the like. Note the local country regulations regarding installation.

WARNING: To prevent injury, this apparatus must be permanently fixed to the ceiling/wall in accordance with the installation instructions.

The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product.
Symbol

Carrier assumes no responsibility for any errors, which may appear in this manual. Furthermore, Carrier reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Carrier does not make any commitment to update the information contained herein.

©2023 Carrier. All Rights Reserved. All trademarks and service marks referred herein are property of their respective owners.

Manufacturer: Carrier Fire & Security Danmark A/S, Ellekær 9A, 2. Th, DK-2730. Manufactured in P.R.C.

Contact: info@cavius.com. www.cavius.com

CAVIUS logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals