COSTWAY ES10111US-GR Commercial Dehumidifier User Manual

May 15, 2024
COSTWAY

COSTWAY ES10111US-GR Commercial Dehumidifier

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-PRODUCT

Product Information

Product Usage Instructions

  • Before You Start
    • Ensure you read the instruction booklet containing important safety information before using the appliance. Keep it for future reference.
  • Operational Precautions
    • Follow these precautions to reduce the risk of fire, electric shock, or injury:
    • If the supply cord is damaged, it must be replaced by the manufacturer or qualified persons.
    • Disconnect the appliance from its power source during service.
    • Operate the unit from a power source with equal voltage, frequency, and rating as indicated.
  • Safety Precautions on Servicing
    • When servicing the appliance with R32 refrigerant, follow these precautions:
  • Checks to the Area:
    • Before beginning work on systems containing flammable refrigerants, conduct safety checks to minimize the risk of ignition.

FAQs

  • Q: What should I do if the supply cord is damaged?
    • A: If the supply cord is damaged, it must be replaced by the manufacturer or similarly qualified persons to avoid hazards.
  • Q: How should I operate the unit for safety?
    • A: Always operate the unit from a power source with equal voltage, frequency, and rating as indicated on the product identification plate.

Before You Start

  • Please read all instructions carefully.
  • Retain instructions for future reference.
  • Separate and count all parts and hardware.
  • Read through each step carefully and follow the proper order.
  • We recommend that, where possible, all items are assembled near the area in which they will be placed in use, to avoid moving the product unnecessarily once assembled.
  • Always place the product on a flat, steady and stable surface.
  • Keep all small parts and packaging materials for this product away from babies and children as they potentially pose a serious choking hazard.

BEFORE YOU BEGIN

PRODUCT DESCRIPTION

  • This dehumidifier removes moisture of the room, which is commonly used in the basement, warehouse, villa and many so on.
  • The environmentally friendly R32 is used as the refrigerant R32 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide.
  • Because of its efficient energy properties, the R32 is highly suitable as a coolant for this application. Precautions must be taken into consideration due to the coolant’s flammability.

SYMBOLS FROM THE UNIT AND USER MANUAL

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1
\(1\)

  • THE FOLLOWINGS SHOULD ALWAYS BE OBSERVED FOR SAFETY
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • This appliance is designed to use indoor, not for outdoor.
  • The unit is designed only for use with R32(propane) gas as the designated refrigerant.
  • The refrigerant loop is sealed. Only a qualified technician should attempt to service!
  • Do not discharge the refrigerant into the atmosphere.
  • R32 (propane) is flammable and heavier than air.
  • It collects first in low areas but can be circulated by the fans.
  • If propane gas is present or even suspected, do not allow untrained personnel to attempt to find the cause.
  • The propane gas used in the unit has no odour.
  • The lack of smell does not indicate a lack of escaped gas.
  • If a leak is detected, immediately evacuate all persons from the store, ventilate the room and contact the local fire department to advise them that a propane leak has occurred.
  • Do not let any persons back into the room until the qualified service technician has arrived and that technician advises that it is safe to return to the room.
  • No open flames, cigarettes or other possible sources of ignition should be used inside or in the vicinity of the units.
  • Parts are designed for propane and non-incentive and non-sparking. Parts shall only be replaced with identical repair parts.
  • FAILURE TO ABIDE BY THIS WARNING COULD RESULT IN AN EXPLOSION, DEATH, INJURY AND PROPERTY DAMAGE.

FOR YOUR SAFETY

Your safety is the most important thing we concerned!

WARNING: Please read this manual carefully and fully understand it before operating your appliance.

OPERATIONAL PRECAUTIONS

WARNING- to reduce the risk of fire, electric shock or injury to persons or property:

  • If the supply cord is damaged, it must be replaced by the manufacturer, or similarly qualified persons to avoid a hazard.
  • The appliance shall be disconnected from its power source during service.
  • Always operate the unit from a power source of equal voltage, frequency and rating as indicated on the product identification plate.
  • Always use a power outlet that is grounded.
  • Unplug the power cord when cleaning or when not in use.
  • Do not operate it with wet hands. Prevent water from spilling onto the unit.
  • Do not immerse or expose the unit to rain, moisture or any other liquid.
  • Do not leave the unit running unattended. Do not tilt or turn over the unit.
  • Do not unplug while the unit is operating.
  • Do not unplug by pulling on the power cord.
  • Do not use an extension cord or an adapter plug.
  • Do not put objects on the unit.
  • Do not climb or sit on the unit.
  • Do not insert fingers or other objects into the air outlet.
  • Do not touch the air inlet or the aluminium fins of the unit.
  • Do not operate the unit if it is dropped, damaged or showing signs of product malfunction.
  • Do not clean the appliance with any chemicals.
  • Ensure the unit is far away from fire, inflammable, or explosive objects.
  • The unit shall be installed per national wiring regulations.
  • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • The appliance shall be stored in a room without continuously operation sources (for example: open flames, an operating gas appliance or an operating electric heater).
  • The appliance shall be stored to prevent mechanical damage from occurring.
  • Do not pierce or burn, even after use.
  • Be aware that refrigerants may not contain an odour.
  • Pipe-work shall be protected from physical damage and shall not be installed in an unventilated space if that space is smaller than 4 m²/43sq.ft.
  • Compliance with national gas regulations shall be observed.
  • Keep any required ventilation openings clear of obstruction.
  • The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1 \(2\)

SAFETY PRECAUTIONS ON SERVICING

  • Please follow these warnings when to undertake the following when servicing an appliance with R32.

Checks to the area

  • Before beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.

Work procedure

  • Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapour being present while the work is being performed.

General work area

  • All maintenance staff and others working in the local area shall be instructed on the nature of the work being carried out. Work in confined spaces shall be avoided. The area around the work space shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.

Checking for the presence of refrigerant

  • The area shall be checked with an appropriate refrigerant detector before and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. no sparking, adequately sealed or intrinsically safe.

Presence of a fire extinguisher

  • If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.

No ignition sources

  • No person carrying out work about a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repair, removal and disposal, during which flammable refrigerant can be released to the surrounding space.
  • Before work takes place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed.

Ventilated area

  • Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.

Checks to the refrigeration equipment

  • Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt, consult the manufacturer’s technical department for assistance.
  • The following checks shall be applied to installations using flammable refrigerants:
    • The charge size is by the room size within which the refrigerant-containing parts are installed;
    • The ventilation machinery and outlets are operating adequately and are not obstructed;
    • If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant;
    • Marking the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected;
    • refrigeration pipe or components are installed in a position where they are unlikely to be exposed to any substance that may corrode refrigerant-containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.

Checks to electrical devices

  • Repair and maintenance of electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
  • If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used.
  • This shall be reported to the owner of the equipment so all parties are advised.

Initial safety checks shall include:

  • those capacitors are discharged: this shall be done safely to avoid the possibility of sparking;
  • that no live electrical components and wiring are exposed while charging, recovering or purging the system;
  • that there is continuity of earth bonding.
  • WARNING! The appliance shall be installed, operated and stored in a room with a floor area larger than 4㎡/43sq.ft. Do not install the unit in a place where inflammable gas may leak.
  • NOTE! The manufacturer may provide other suitable examples or may provide additional information about the refrigerant odour.

SPECIFICATIONS

Model No. ES10111US-GR
Voltage & Hertz AC115V / 60Hz
Rated Input Current 4.7A @65 oF, 60% RH
MAX. Input Current 6.9A
Refrigerant Charge R32/6.71oz

Dehumidify Capacity

| 46Pints/Day @65 oF, 60% RH

115Pints/Day @86 oF, 80% RH

Maximum Design

Pressure

| High Side: 550psi

Low Side: 260psi

BCSC| 15A
Compressor Input| RLA:5.5A LRA:27A
Fan Motor Power| 0.100HP

PRODUCT DRAWINGS

Front

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1
\(3\)

Back

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1
\(4\)

INSTALLATION

Handle and Support Frame Installation

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1
\(5\)

  1. Main Body
  2. Handle
  3. Stainless Steel Bolt
  4. Spacer
  5. Wheel
  6. Spacer
  7. Nut
  8. Support Frame

Drainage Installation

  1. When the tank is full, the “FULL” light will turn on.
  2. The unit will make a buzzing sound. To stop this, press the power button to turn off the machine.
  3. To empty the water tank, open the front panel to access the water tank.
  4. Grab the handle of the water tank and pull it out horizontally.
  5. After disposing of the water, replace the tank and close the front panel.

Continuous drainage

In extremely wet conditions, the tank may need frequent clearing. It can be set up for continuous drainage by doing the following:

  1. Open the front cover, remove the tank, and clear the water from the tank.
  2. Remove the plug and install the included drain pipe to the connector, direct the pipe to the desired area before operating the machine. See the pictures below.
  3. Make sure the water tank and drain pipe are not blocked, and shut the front panel.
  4. When you do not use continuous drainage and turn to use the water tank again, just use the plug to stop the water outflow from the connector.COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1 \(7\)
    • WARNING: Do not block the drainage hose. The end of the drainage pipe should not be higher than the outlet hole. If the drainage pipe end is higher than the outlet hole, water will not drain properly and could damage components of the unit.

MACHINE SETUP AND OPERATION

COSTWAY-ES10111US-GR-Commercial-Dehumidifier-FIG-1
\(8\)

Button Function

  1. * Press this button while on electricity, the screen light is on, the machine automatically goes to continuous mode, the display screen shows environmental humidity, compressor is on after the fan runs for 3 seconds; press this button again, and the compressor stops, the display screen shows “- -”, the machine goes into standby mode, the fan will run for another minute and stop.
    • Press this button while the machine is on electric, until the button light goes on, press “MINUS” or “ADD” to set the time to start the machine, when the countdown is over, the fan and compressor turn on.
    • Press this button while the machine is running, until the button light goes on, press “MINUS” or “ADD” to set the time to stop the machine, when the countdown is over, the fan and compressor will shut off.
    • Press this button for 3 seconds to show the current temperature. After 10 seconds, the display will return to show the current humidity.
    • The humidity can be increased by increments of 5%RH during normal mode. Hold this button for 1 second to increase the humidity continuously.
    • The humidity can be decreased by increments of 5%RH during normal mode.
    • Hold this button for 1 second to decrease the humidity continuously.
    • Note:
      • The default humidity is 50%RH, to increase and decrease as follow: 20%- 25%– 30%- 35%-40%45%-50%-55%-60%-65%-70% -75%-80%-85%-90%
      • Environmental humidity and machine-set humidity will decide the status of the compressor and fan as follow:
      • Environmental humidity ≥machine set humidity +3%, compressor and fan start running.
      • Environmental humidity < machine set humidity +3%, compressor and fan stop running.
    • During continuous mode, the humidity setting is unavailable.
    • Continuous mode light turns on and the screen will display the current humidity.
    • Press this button to switch to normal mode where the humidity setting will be available.

Operation

  1. When the water tank is full, the water tank light goes on red and the alarm goes on after 5 seconds. The buzzer beeps 15 times and the compressor and fan shut off. After the water tank is emptied, the machine will automatically switch to the previous mode while the compressor will be in 3 minutes of self-protect. The alarm will stop in 3 seconds after the water tank is emptied and put back, the fan starts, and the compressor will start in 3 minutes.
  2. The compressor will not need 3 minutes to self-protect if it is the first time to start the machine, press “POWER” and power off; power on, press “POWER”, and the compressor starts immediately.
  3. The system has auto memory. When all the mode settings have been finished, if there is a sudden power cut during operation, or the power jack slips out, the system may store the current status before the power is cut and enter the operation mode before the power cut automatically after the power is supplied.

Defrost Function

  1. The compressor and fan will shut off when the environmental temperature goes below 41 °F or above 100.4°F.
  2. Defrost requirement: The compressor runs for 30 minutes, the temperature sensor senses the temperature ≤ 30.2°F, (last for 10 seconds), the compressor stops, defrost starts, fan continues, defrost light turns on, and when the pipe temperature goes to 41ºF or the defrost last for 15 minutes, defrost stops.
    • Note: During defrosting, the light won’t be off until the defrosting is over.

ERROR

  1. “E1”: If the copper head sensor fails, it will show “E1”. The system works in cycles of dehumidification for 20 minutes and defrosting for 15 minutes. The copper head sensor should be replaced with a new one.
  2. “E2”: If the humidity sensor fails, it will show “E2”. The humidity adjusting button will not work. The system works in cycles of dehumidification for 15 minutes and defrosting for 15 minutes. The failure humidity sensor should be replaced with a new one.
  3. “FL”: When the water tank is full, it will show “FL”. The machine will make a buzzing sound and stop working. Remove the water from the tank and install it properly.

MAINTENANCE

Clean the machine with a soft wet cloth. Pull the louvre on the front panel out to gain access to the filter.

Remove the filter mesh from the unit. Use a clean rag to adsorb the surface dust on the filter mesh.

  • If the filter is extremely dirty, use tap water to flush the filter.
  • Fully dry the filter before putting it back into the air inlet fence. A clean filter will increase the machine’s efficiency.

MACHINE STORAGE

If you don’t use the unit for an extended period, please store it per the following steps:

  1. Clean the filter mesh.
  2. ATTENTION: The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and moulds. Unplug the unit and place it in a dry open area for days to dry it out. Another way to dry the unit is to set the humidity point more than 2% higher than the ambient humidity to force the fan to dry the evaporator for a couple of hours.
  3. Store the power cord pocket at the back of the unit.
  4. Store in a clean, dry environment.

TROUBLESHOOTING

Trouble Cause Solution
The machine does not run The unit is not plugged in. Plug in the unit.

Room temperature under 41 degrees or above

degrees F.

| To protect the machine, use it only when the ambient temperature is between 5 and 38 degrees.
The machine runs but does not dehumidify| When the humidity set point is 2% higher than ambient humidity.| Reset the humidity to a lower set point, or power off the machine if the humidity has satisfied you.
Reduce dehumidifier capacity| Filter mesh jammed.| Clean the filter mesh according to the manual.
---|---|---
Air-in and/or Air-out louvers jammed.| Clear the blockage from Air-in and/or Air-out louvres.
No air inlet| Filter mesh or air-in louvre jammed.| Clean the filter according to instructions or clean the louvre blockage.
Loud Operation| Machine situated on an incline or decline slope.| Move to flat ground.
Filter mesh jammed.| Clean filter mesh according to instructions.

Cautions: Switch off the unit and unplug it immediately if anything abnormal happens. Then contact qualified personnel. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local regulation for information regarding the collection systems available.

Return / Damage Claim Instructions

  • DO NOT discard the box / original packaging.
    • In case a return is required, the item must be returned in the original box. Without this, your return will not be accepted.
  • Take a photo of the box markings.
    • A photo of the markings (text) on the side of the box is required in case a part is needed for replacement. This helps our staff identify your product number to ensure you receive the correct parts.
  • Take a photo of the damaged part (if applicable).
    • A photo of the damage is always required to file a claim and get your replacement or refund processed quickly. Please make sure you have the box even if it is damaged.
  • Send us an email with the images requested.
    • Email us directly from the marketplace where your item was purchased with the attached images and a description of your claim.
    • USA office: Fontana
    • AUS office: Truganina
    • GBR office: Ipswich
    • FRA office: Saint Vigor d’Ymonville
  • If you’re having difficulty, our friendly customer team is always here to help.

THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ AND KEEP FOR FUTURE REFERENCE.