PACKAGING CONTENTS

Meconard-RD-RD401-XX-4-Inch-5CCT-LED-Recessed-Lighting-Can-Lights-
FIG-1

WARNING
The retrofit kit is accepted as a component of a luminaire where the suitability of the combination shall be determined by authorities having jurisdiction. product must be installed by a qualified electrician in accordance with the applicable and appropriate electrical codes. the installation guide does not supersede local or national regulations for electrical installations.

  • Warning – risk of fire or electric shock. installation of this retrofit assembly requires a person familiar with the construction and operation of the luminaire’s electrical system and the hazard involved. if not qualified, do not attempt installation. contact a qualified electrician.
  • Warning – risk of fire or electric shock. led retrofit kit installation requires knowledge of luminaire electrical systems. if not qualified, do not attempt installation. contact a qualified electrician. Warning – risk of fire or electric shock. install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.
  • Warning – to prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.

Please examine all parts that are not intended to be replaced by the retrofit kit for damage and replace any damaged parts before installation of the retrofit kit.

Warning -this device is not intended for use with emergency exits. The product is intended to retrofit type ic or type non-ic recessed mount listed luminaires that use one lamp with or without a diffuser, the minimum lamp compartment dimensions are tabulated below:Meconard-RD-RD401-XX-4-Inch-5CCT-
LED-Recessed-Lighting-Can-Lights-FIG-3

ELECTRICAL PARAMETERS

Meconard-RD-RD401-XX-4-Inch-5CCT-LED-Recessed-Lighting-Can-Lights-
FIG-4

  • Product size: Ф131.2*37
  • Unit: mm

Installation steps

STEP1:
Disconnect power before servicing. Remove the existing bulb or remove the existing trim if necessary.

STEP2: As shown in figure 1
Screw E26 Edison base Lampholder Fitting or GU24 base Lampholder Fitting into an existing base socket in the housing.

STEP3: As shown in figure 2 Consumers use dip switches to adjust the color temperature according to their actual situation.

STEP4: As shown in figure 3 Push 3 shrapnel to the trim boss (as shown below), and connect the lamp base to LED retrofit kit by connector.

STEP 5 : As shown in figure 4 Three shrapnel faces straight at the housing (as shown in Figure 4), and then push the LED retrofit kit into the recessed light fixture until its outer edge is flush against the ceiling surface.

STEP6: As shown in figure 5 Turn on the power supply.

Others: As shown in figure 6 Turn on the power supply.