Thank your choosing our product and your trust in our company. To help you get maximum pleasure from using this product, please read this instruction manual carefully and operate strictly according to the user manual before starting the machine, otherwise the machine may be damaged or cause you unnecessary harm.

Application

  1. Set swimming pool water temp efficiently and economically to provide you comfort and pleasure.
  2. User may choose the model technical parameter according to professional guide, this series of swimming pool heater has been optimized in factory (refer to technical parameter table).

Features

  1. High efficient titanium heat exchanger.
  2. Sensitive and accurate temp control and water temp display.
  3. High pressure and low pressure protection.
  4. Exceeding low temp auto stop protection.
  5. Temp control compulsory defrosting.
  6. International brand compressor.
  7. Easy installation and operation.

Technical Parameter

Model| BPN06| BPN08| BPN09| BPN13| BPN17| BPN21| BPN25
---|---|---|---|---|---|---|---
Advised pool volume (m 3)| 14~28| 20~35| 20~40| 30~55| 35-70| 45-85| 55-100
Operating air temperature ()| 0~43
Performance Condition: Air 26°C, Water 26°C, Humidity 80%
Heating capacity (kW)| 6.5| 8.0| 9.2| 12.5| 16.5| 20.5| 25.0
Performance Condition: Air 15°C, Water 26°C, Humidity 70%
Heating capacity (kW)| 4.5| 6.0| 7.0| 9.0| 11.5| 14.0| 17.0
Rated input power at air 15°C (kW)| 0.35~1.0| 0.34~1.4| 0.34~1.6| 0.36~2.0| 0.56~2.7| 0.6~3.4| ** 0.68~3.95
Rated input current at air 15°C (A)| ** 1.52~4.4| 1.48~6.0| 1.48~7.0| 1.57~8.7| 2.43~11.7| 2.6~15.0| 2.95~17.1
Max input current (A)| 6.5| 8.0| 9.5| 12.5| 15.0| 19.5| 21.5
Power supply| 230V/1 Ph/50Hz
Advised water flux  (m³/h)| 2~4| 2~4| 3~4| 4~6| 6~8| 8~10| 10~12
Water pipe in-out Spec (mm)| 50
Net Dimension LxWxH (mm)| 744×359× 648| 864×359× 648| 864×359× 648| 864×359× 648| 954×359× 648| 954×359× 748| 1084×429× 948
Net Weight       (kg)| 42| 46| 47| 49| 60| 68| 90

Notice:

  1. This product can work well under air temp 0℃~+43℃, efficiency will not be guaranteed out of this range. Please take into consideration that the pool heater performance and parameters are different under various conditions.
  2. Related parameters are subject to adjustment periodically for technical improvement without further notice. For details please refer to nameplate.

Dimension

Comfort Line BPN06 Inverter Swimming Pool Heat Pump -
Dimension

| UNIT=MM| A| B| C| D| E| F| G| H
---|---|---|---|---|---|---|---|---|---
MODEL| BPN06| 334| 490| 318| 359| 744| 330| 74| 648
BPN08| 334| 560| 318| 359| 864| 250| 74| 648
BPN09| 334| 560| 318| 359| 864| 250| 74| 648
BPN13| 334| 560| 318| 359| 864| 290| 74| 648
BPN17| 334| 590| 318| 359| 954| 350| 74| 648
BPN21| 334| 590| 318| 359| 954| 390| 74| 748
BPN25| 395| 720| 392| 420| 1092| 620| 74| 958

※ Above data is subject to modification without notice.

Note:
The picture above is the specification diagram of the pool heater, for technician’s installation and layout reference only. The product is subject to adjustment periodically for improvement without further notice.

Installation instruction

  1. Drawing for water pipes connectionComfort Line BPN06 Inverter Swimming Pool Heat Pump - pipes connection( Notice: The drawing is just for demonstration, and layout of the pipes is only for reference.)

  2. Connecting your power wireComfort Line BPN06 Inverter Swimming Pool Heat Pump - ower wire① Please use cross screwdriver to take off the 2 screws at the bottom of the right side panel. Take off the lower half of the panel.
    ② Unscrew the 3 screws on the cover of the electrical box.
    ③ Connect the terminals according to the electrical diagram.
    ( Note: please open the back panel for power connection. The operation is the same as above.)
    For power supply: 230V 50HzComfort Line BPN06 Inverter Swimming Pool Heat
Pump - power supply Note:
    Must be hard wired, no plug allowed (In Australia, BPN06~BPN09 has plug for optional).
    The swimming pool heater must be earthed well

  3. Electric Wiring Diagram
    Options for protecting devices and cable specification MODEL| BPN06| BPN08| BPN09| BPN13| BPN17| BPN21| BPN25
    ---|---|---|---|---|---|---|---
    Breaker| Rated Current A| 8.0| 9.5| 11.5| 15.0| 18.0| 23.0| 25.0
    Rated Residual Action Current mA|
    30| 30| 30| 30| 30| 30| 30
    Fuse   A| 8.0| 9.5| 11.5| 15.0| 18.0| 23.0| 25.0
    Power Cord  (mm2)| 3×1.5| 3×1.5| 3×2.5| 3×2.5| 3×4| 3×4| 3×6
    Signal cable (mm2)| 3×0.5| 3×0.5| 3×0.5| 3×0.5| 3×0.5| 3×0.5| 3×0.5

※ Above data is subject to modification without notice.
Note: The above data is adapted to power cord ≤ 10m. If power cord is>10m, wire diameter must be increased. The signal cable can be extended to 50m at most.

  1. Installation instruction and requirement
    The heat pump must be installed by a professional team. The users are not qualified to install by themselves, otherwise the heat pump might be damaged and risky for users’ safety.

A. Installation

  1. The inlet and outlet water unions can’t bear the weight of soft pipes. The heat pump must be connected with hard pipes!Comfort Line BPN06 Inverter Swimming Pool Heat Pump - pump
  2. In order to guarantee the heating efficiency, the water pipe length should be ≤10m between the pool and the heat pump. 

B. Installation instruction

  1. Location and size
    **** The heat pump should be installed in a place with good ventilationComfort Line BPN06 Inverter Swimming Pool Heat Pump -
ventilation

  2. The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid and fastened; the bracket must be strong enough antirust treated;

  3. Please don’t stack substances that will block air flow near inlet or outlet area, and there is no barrier within 50cm behind the main machine, or the efficiency of the heater will be reduced or even stopped;

  4. The machine needs an appended pump (Supplied by the user). The recommended pump specification-flux: refer to Technical Parameter, Max. lift ≥10m;

  5. When the machine is running, there will be condensation water discharged from the bottom, please pay attention to it. Please hold the drainage nozzle (accessory) into the hole and clip it well, and then connect a pipe to drain the condensation water out.

C.Wiring

  1. Connect to appropriate power supply, the voltage should comply with the rated voltage of the products.
  2. Earth the machine well.
  3. Wiring must be handled by a professional technician according to the circuit diagram.
  4. Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
  5. The layout of power cable and signal cable should be orderly and not affecting each other.

D . Switch on after finishing all wiring construction and re-checking.

Operation instruction

Comfort Line BPN06 Inverter Swimming Pool Heat Pump - Operation
instruction

SYMBOL DESIGNATION OPERATION
Power ON/OFF Press to power on or off the heat pump
Mode Press to select Smart/Silence mode
Up/ Down Press to set desired water temperature

Note:

  • You may set the desired water temperature from 18 to 35℃.
  • The on the right shows the inlet water temperature. The on the left shows the set temperature by pressing or button.
  • After you turn on the heat pump, the fan will start to run in 3 minutes. In another 30 seconds, the compressor will start to run.
  • During heating, the will be light. During cooling, will be light.

2.2.1. Mode selections

  • Smart will be light as standard when you turn on the heat pump.
  • Press the button to enter the Silence mode, the will  be light.
    Press the  button again to exit and enter the SMART mode.

2.2.2. Compulsory defrosting

  • When the heat pump is heating and the compressor is working  continuously for 10 minutes, press both and buttons for 5 seconds to start compulsory defrosting. (Note: the interval between compulsory defrosting should be more than 30 minutes.)
  • The heating light will be twinkling when heat pump is in compulsory or auto defrosting.
    The running process and ending of compulsory defrosting are the same as auto- defrosting.

Testing

  1. Inspection before use
    A. Check installation of the whole machine and the pipe connections according to the pipe connecting drawing;
    B. Check the electric wiring according to the electric wiring diagram and earthing connection;
    C. Make sure that the main machine power switch is off;
    D. Check the temperature setting;
    E. Check the air inlet and outlet.

  2. Trial
    A. The user must “Start the Pump before the Machine, and Turn off the Machine before the Pump”, or the machine will be damaged;
    B. The user should start the pump, check for any leakage of water; and then set suitable temperature in the thermostat, and then switch on power supply;
    C. In order to protect the swimming pool heater, the machine is equipped with a time lag starting function, when starting the machine, the blower will run 1 minutes earlier than the compressor;
    D. After the swimming pool heater starts up, check for any abnormal noise from the machine.

Precautions

  1. Attention
    A. Set proper temperature in order to get comfortable water temperature to avoid overheating or overcooling;
    B. Please don’t stack substances that can block air flow near inlet or outlet area, or the efficiency of the heater will be reduced or even stopped;
    C. Please don’t put hands into outlet of the swimming pool heater, and don’t remove the screen of the fan at any time;
    D. If there are abnormal conditions such as noise, smell, smoke and electrical leakage, please switch off the machine immediately and contact the local dealer. Don’t try to repair it yourself;
    E. Don’t use or stock combustible gas or liquid such as thinners, paint and fuel to avoid fire;
    F. In order to optimize the heating effect, please install heat preservation insulation on pipes between swimming pool and the heater. During running period of the swimming pool heater, please use a recommended cover on the swimming pool;
    G. Connecting pipes of the swimming pool and the heater should be ≤10m, or the heating effect of the heater cannot be ensured;
    H. This series of machines can achieve high efficiency under air temperature of +15℃~+25℃.

  2. Safety
    A. Please keep the main power supply switch far away from the children;
    B. When a power cut happens during running, and later the power is restored, the heater will start up automatically. So please switch off the power supply when there is a power cut, and reset temp when power is restored;
    C. Please switch off the main power supply in lightning and storm weather to prevent from machine damage that caused by lightning;
    D. If the machine is stopped for a long time, please cut off the power supply and drain water clear of the machine by opening the tap of inlet pipe.

Maintenance

Caution: Danger of electric shock
“Cut off” power supply of the heater before cleaning, examination and repairing
A. In winter season when you don’t swim:

  1. Cut off power supply to prevent any machine damage
  2. Drain water clear of the machine. Caution: Danger of electric shockComfort Line BPN06 Inverter Swimming Pool Heat Pump - Unscrew
  3. Cover the machine body when not in use.
    B. Please clean this machine with household detergents or clean water, NEVER use gasoline, thinners or any similar fuel.
    C.Check bolts, cables and connections regularly.

Trouble shooting for common faults

FAILURE REASON SOLUTION

Heat pump doesn’t run

| No power| Wait until the power recovers
Power switch is off| Switch on the power
Fuse burned| Check and change the fuse
The breaker is off| Check and turn on the breaker
Fan running but with insufficient heating| evaporator blocked| Remove the obstacles
Air outlet blocked| Remove the obstacles
3 minutes start delay| Wait patiently
Display normal, but no heating| Set temp. too low| Set proper heating temp.
3 minutes start delay| Wait patiently
If above solutions don’t work, please contact your installer with detailed information and your model number. Don’t try to repair it yourself.

Note: If the following conditions happen, please stop the machine immediately, and cut off the power supply immediately, then contact your dealer:
a)Inaccurate switch action;
b)The fuse is frequently broken or leakage circuit breaker jumped.

Failure code

NO. DISPLAY NOT FAILURE DESCRIPTION
1 E3 No water protection
2 E5 Power supply excesses operation range
 3  E6 Excessive temp difference between inlet and outlet water(Insufficient

water flow protection)
4| Eb| Ambient temperature too high or too low protection
5| Ed| Anti-freezing reminder
NO.| DISPLAY| FAILURE DESCRIPTION
1| E1| High pressure protection
2| E2| Low pressure protection
3| E4| 3 phase sequence protection (three phase only)
4| E7| Water outlet temp too high or too low protection
5| E8| High exhaust temp protection
6| EA| Evaporator overheat protection (only at cooling mode)
7| P0| Controller communication failure
8| P1| Water inlet temp sensor failure
9| P2| Water outlet temp sensor failure
10| P3| Gas exhaust temp sensor failure
11| P4| Evaporator coil pipe temp sensor failure
12| P5| Gas return temp sensor failure
13| P6| Cooling coil pipe temp sensor failure
14| P7| Ambient temp sensor failure
15| P8| Cooling plate sensor failure
16| P9| Current sensor failure
17| PA| Restart memory failure
18| F1| Compressor drive module failure
19| F2| PFC module failure
20| F3| Compressor start failure
21| F4| Compressor running failure
22| F5| Inverter board over current protection
23| F6| Inverter board overheat protection
24| F7| Current protection
25| F8| Cooling plate overheat protection
26| F9| Fan motor failure
27| Fb| Power filter plate No-power protection
28| FA| PFC module over current protection

Appendix 1: Heating priority (Optional)

Comfort Line BPN06 Inverter Swimming Pool Heat Pump - Heating
priority

Appendix 2: Heating priority (Optional)

Comfort Line BPN06 Inverter Swimming Pool Heat Pump - Heating priority
1Parallel connection with filtration clock
A: Water pump timer B: Water pump wiring of Heat Pump
Note: The installer should connect A parallel with B (as above picture). To start the water pump, condition A or B is connected. To stop the water pump, both A and B should be disconnected.

Comfort Line Logo Version:B00IN

Documents / Resources

| Comfort Line BPN06 Inverter Swimming Pool Heat Pump [pdf] User Manual
BPN06, BPN08, BPN09, BPN13, BPN17, BPN21, BPN25, BPN06 Inverter Swimming Pool Heat Pump, Inverter Swimming Pool Heat Pump, Swimming Pool Heat Pump, Heat Pump, Pump
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals