BAXI 50 UBPU SLIM EPS Instruction Manual

May 15, 2024
BAXI

BAXI-logo

BAXI 50 UBPU SLIM EPS

BAXI-50-UBPU-SLIM-EPS-product-image

Product Specifications

  • Model: UBPU SLIM EPS
  • Capacity: 50 L
  • Dimensions: 1110mm x 316mm x 310mm
  • Insulation Thickness: 3mm
  • Max Pressure: 3 bar
  • Max Temperature of Boiler: 95°C

Product Usage Instructions

Installation Instructions
The following information is essential for the validity of the warranty. The installation must:

  1. Be done according to the provided guidelines.
  2. Ensure proper connection to the heating outlet and drain.
  3. Maintain insulation with a thickness of 3mm.
  4. Operate within the specified maximum pressure of 3 bar.

Maintenance Instructions
Maintenance must:

  1. Be performed regularly to ensure optimal performance.
  2. Check for leaks or damage to the tank.
  3. Keep the tank clean and free from debris.

Disposal Guidelines
Disposal must take place in accordance with local regulations for electronic waste disposal. Do not dispose of the product in regular trash.

Frequently Asked Questions (FAQ)

  • Q: Can I install the tank myself?
    A: It is recommended to have the tank installed by a professional plumber to ensure proper setup and adherence to warranty guidelines.

  • Q: What should I do if I notice a leak?
    A: If you notice a leak, immediately turn off the water supply to the tank and contact a qualified technician for repair.

  • Q: How often should maintenance be performed?
    A: Regular maintenance checks should be conducted at least once a year to ensure the tank functions correctly.

INSTRUCTION FOR INSTALLATION AND MAINTENANCE

BAXI-50-UBPU-SLIM-EPS-fig- \(1\)

CONNECTOR TYPE MODEL

UBPU SLIM
1| Air evacuation| 3/8”
2| Heating inlet| 1”
3| Feeler| Ø10
4| heating outlet| 1”
5| Drain| 1/2″
6| Boiler outlet| 1”
7| Boiler inlet| 1”
Model| | UBPU SLIM
---|---|---
Insulation| | EPS
Insulation thickness| mm| 50
Max pressure| bar| 3
Max T of boiler| °C| 95
overall dimensions| mm| h 1110 x s 316 x s 310

INSTALLATION INSTRUCTIONS

The following information is essential for the validity of the warranty.

  1. The installation must:
  2. be carried out by a qualified installer and comply with all applicable regulations;
  3. Provide, where necessary, a pressure reducer for the incoming water.
  4. Provide a safety valve set at a pressure lower than the maximum pressure indicated on the storage tank’s technical data plate.
  5. Provide an expansion vessel (see expansion vessel sizing table) proportioned to the dimensions of the storage tank (it is advisable to have the size calculated by a specialised technician).
  6. Guarantee enough space to perform maintenance operations.
  7. Provide a spill-proof tank, suitably connected to a siphoned drain of sufficient capacity to contain any accidental water spills, if any spills would cause damage to property.
  8. Be carried out in an environment where the boiler cannot freeze and, in any case, where it is not exposed to the elements.
  9. The temperature of the contents of the boiler must always be below 95°C.
  10. The cylinder are not designed for vacuum or negative pressure applications.
  11. The product is not designed to withstand external loads from wind and/or earthquakes.
  12. The product is not designed to withstand loads through the connections.
  13. Carry out a leak test to check that the connections are tight.
  14. Always use suitable equipment to lift and transport the product. It is recommended to always move the tanks when they are empty.
  15. Maintenance must:
  16. Be carried out when the system is stopped, disconnected from any electrical power supplies and with the tank empty. Before proceeding with maintenance operations, check the temperature and pressure conditions of the system.
  17. Be carried out by a specialised technician at least once a year. While carrying out maintenance, the technician must:
  18. check the efficiency of all the safety valves installed in the system;
  19. check the pre-charge pressure of the expansion vessels and, if necessary, restore it.
  20. Failure to comply with the above will invalidate the Conventional Warranty.
  21. Disposal must take place:
  22. At the end of the service life of the product. Dispose of the product according to the laws in force in the country of installation. The components (metallic and non-metallic) must be taken to an authorised recycling company. The product must not be treated as household waste.

DIMENSIONING OF THE EXPANSION TANK:
The volume of the expansion vessel must be carefully dimensioned by a thermal- engineering.

  • Our Company declares that these products are certified, according to the following regulations:
    • Directive 2009/125/EC
    • Regulation (EU) 2017/1369
    • Directive 2014/68/EU – ART.4, Sub.3
    • EN 12897:2020 (Appendix B)
    • Delegated Regulation (EU) No 812/2013
    • Regulation (EU) No 814/2013
  • Our company, in its constant attempt to improve its products, reserves the right to modify the data contained in this documentation at any time and without prior notice. This documentation is for information purposes only and must not be considered as a contract with third parties.

SIZE ( I N S U L . )| CAPACITA ( L )| STANDING LOSS

(W)

| ENERGY CLASS
---|---|---|---
UBPUSLIM| 34| 2 7| B

BAXI-50-UBPU-SLIM-EPS-fig- \(3\)

https://techarea.baxi.it/certificati/garanzia_convenzionale.pdf
Servizio Clienti Baxi
Tel. +39 0424 517 800
E-mail: servizioclienti@baxi.it

Data of S.N. Label

34| Sanit. Nom. .| –       L| | PS| – bar
| Construction material| 1.4301 / AISI 304
Treatment| –
Nom. Cap. Heating| 34 L| | PS| 3 bar
Fixed higher exchanger| –       L| –       m²| PS| – bar
Higher coil power.| –       kW| –       L/h|
Fixed lower exchanger| –      L| –     m²| PS| – bar
Lower coil power| –       kW| –       L/h|
Working. Temperature Max.| 95°C| |
Standing Losses| 27 W| |
Weight empty| 10 kg| |
Encumbered for| 1110 mm| |
Anode| n° –| Mis. ØxLg. –| mm –

ACCESSORIES

Guide to installing the accessories:
The following kit, code: A7855160 is available separately for wall mounting of the tank.

This kit consists of:

  1. N.2 brackets for fixing to the wall
  2. N.4 dowels 6×30
  3. N.4 screws 4,5×45

Necessary equipment:

  • Meter
  • Bubble level
  • Drilling machine
  • ScrewdriverBAXI-50-UBPU-SLIM-EPS-fig- \(5\)

Mounting instructions:

  • Choose the most suitable position for fixing the tank

  • Take the brackets and place them at the appropriate seat in the tank, place the tank in the wall portion where you want to make the fixing and mark with a pencil the position of the holes.
    (Equipment: meter and Bubble level)

  • Remove the tank and proceed to make the holes at the points previously marked, using a wall tip Ø6.(Equipment: drilling machine and wall tip)

  • Insert the supplied dowels into the holes, reposition the tank and fix it with the specific screws provided.(Equipment: screwdriver or cross screwdriver).BAXI-50-UBPU-SLIM-EPS-fig- \(9\)

  • Check that the tank is well set.

GUARANTEE COUPON

BAXI-50-UBPU-SLIM-EPS-fig- \(10\)

THE TANK HAS BEEN CHECKED THROUGH PRESSURE TEST THAT MEANS 1,3 MORE THAN THE OPERATING PRESSURE

DATA FIRMA OPERATOR

Stamp and signature of installer
36061 Bassano del Grappa (VI) – ITALIA Via Trozzetti, 20 Servizio clienti:
tel. 0424-517800 – Telefax 0424-38089
www.baxi.it

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BAXI User Manuals

Related Manuals