milwaukee L4 TMLED Twist Focus Flashlight Instruction Manual

June 4, 2024
Milwaukee

milwaukee logo

Nothing but HEAVY DUTYmilwaukee L4 TMLED Twist Focus
Flashlight

L4 TILED
Original instructions
Picture section

with operating description and functional description

L4 TMLED Twist Focus Flashlight

milwaukee L4 TMLED Twist Focus Flashlight - fig

milwaukee L4 TMLED Twist Focus Flashlight - fig 1| milwaukee L4 TMLED Twist Focus Flashlight - fig2
---|---

Dual-function power button
Press firmly (click) -> on/off
Press firmly for 1 sec. -> cycle through the modesmilwaukee L4 TMLED Twist
Focus Flashlight - fig 3

WARNING Read all safety warnings, instructions, illustrations, and specifi cations provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.

SAFETY INSTRUCTIONS BATTERY-LAMP

Warning: Do not direct the light beam at persons or animals and do not stare into the light beam yourself (not even from a distance). Staring into the light beam may result in serious injury or vision loss. Don‘t use this tool in wet areas.

SAFETY INSTRUCTIONS BATTERY
Only use Milwaukee Type L4B2, and L4B3 rechargeable batteries.
Remove the battery pack before starting any work on the appliance.
Do not dispose of used battery packs in the household refuse or by burning them. Milwaukee
Distributors off er to retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects (short circuit risk).
Battery acid may leak from damaged batteries under extreme load or extreme temperatures. In case of contact with the battery, acid washes it off immediately with soap and water. In case of eye contact rinse thoroughly for at least 10 minutes and immediately seek medical attention.
Warning! To reduce the risk of fi re, personal injury, and product damage due to a short circuit, never immerse your tool, battery pack or charger in fl uid or al-low a fluid to fl ow inside them. Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach-containing products, etc., Can cause a short circuit.

SPECIFIED CONDITIONS OF USE

The battery lamp is intended to be used light independent use away from the mains supply.
Do not use this product in any other way as stated for normal use.

CHARGING

Plug your USB cable into a power source such as an AC wall adaptor, computer or carport.
The indicator light will display the charging status: Red flashing: charging, 0-49% charged Orange flashing: charging 50-99% charge
Green solid: 100% charged
Red/Green fl ashing: damaged or faulty battery
If the light indicator fl ashes red and green, check that the battery is fully seated into the bay. Remove the battery and reinsert. If the light continues to illuminate solid red, the battery may be extremely hot. Allow the battery to cool down then reinsert. If the problem persists, contact a MILWAUKEE service facility.

FUEL GAUGE

The fuel gauge will display the battery life:
Red flashing: 0-3% remaining
Red solid: 3-10% remaining
Orange solid: 11-49% remaining
Green solid: 50-100% remaining

BATTERIES

Battery packs that have not been used for some time should be recharged before use.
Temperatures in excess of 50°C (122°F) reduce the performance of the battery pack. Avoid extended
exposure to heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum lifetime, the battery packs have to be fully charged, after used.
To obtain the longest possible battery life remove the battery pack from the charger once it is fully charged.
For battery pack storage longer than 30 days: Store the battery pack where the temperature is below 27°C and away from moisture Store the battery packs in a 30% – 50% charged condition
Every six months of storage, charge the pack as normal.

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods Legislation requirements.
Transportation of those batteries has to be done in accordance with local, national and international provisions and regulations.

  • The user can transport the batteries by road without further requirements.

  • Commercial transport of Lithium-Ion batteries by third parties is subject to Dangerous Goods
    regulations. Transport preparation and transport are exclusive to be carried out by appropriately trained persons and the process has to be accompanied by corresponding experts. When transporting batteries:

  • Ensure that battery contact terminals are protected and insulated to prevent short circuits.

  • Ensure that the battery pack is secured against movement within the packaging.

  • Do not transport batteries that are cracked or leak.
    Check with the forwarding company for further advice

MAINTENANCE

The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced.
Use only Milwaukee accessories and spare parts. Should components need to be replaced which have not been described, please contact one of our Milwaukee service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state the machine type printed as well as the six-digit No. on the label and order the drawing at your local service agents or directly at: Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

SYMBOLS

| CAUTION! WARNING! DANGER!
---|---
| Please read the instructions carefully before starting the machine.
| Do not stare at the operating light source.
| Warning! Hot Surface! Do not touch!
| Class III electrical protection.
| Do not dispose electric tools, batteries/rechargeable batteries together with household waste material.
Electric tools and batteries that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility. Check with your local authority or retailer for recycling advice and collection point.
| European Conformity Mark
| British Conformity Mark
| Ukraine Conformity Mark
| Eurasian Conformity Mark

TECHNICAL DATA

……………………………………………………………………………………………………………………………………….L4 TMLED

Rated Power input ……………………………………………………………………………………………………………………….12,8 W
Lighting time with one fully charged battery Mode High ………………………………………………………………..1,0 h
Mode Medium ……………………………………………………………………………………………………………………………..4,0 h
Mode Low ……………………………………………………………………………………………………………………………10,0 h
Luminus flux Mode High …………………………………………………………………………………………………1100 lm
Mode Medium ………………………………………………………………………………………………………………………600 lm
Mode Low …………………………………………………………………………………………………………………………………….100 lm
Charging time ………………………………………………………………………………………………………………………………………..120 min
Color rendering index (CRI)…………………………………………………………………………………………………….80
Color temperature……………………………………………………………………………………………………………………..4000 K
Battery voltage……………………………………………………………………………………………………………………………..4 V
USB input …………………………………………………………………………………………………………………………………..5V DC; 0,1 A – 2,1 A
Weight …………………………………………………………………………………………………………………………………….0,2 kg
Protection class ………………………………………………………………………………………………………………………. IP 67
Recommended ambient operating temperature ………………………………………………………………………….. -18…+50 °C
Recommended ambient charging temperature ………………………………………………………………………………… +5…+40 °C
Recommended battery types…………………………………………………………………………………………………….. L4B2, L4B3
Recommended USB power supply………………………………………………………………………………………………….CUSB

.
https://tm.by
Copyright 2020
Techtronic Industries GmbH
Max-Eyth-Str. 10 71364 Winnenden
Germany
+49 (0) 7195-12-0
www.milwaukeetool.eu
Techtronic Industries (UK) Ltd Fieldhouse Lane
Marlow Bucks SL7 1HZ UK

(12.20) 4931 4704 16

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals