JOYTECH DMT-4770b Digital Thermometer Owner’s Manual Product Information
- May 15, 2024
- Joytech
Table of Contents
DMT-4770b Digital Thermometer
“`html
Product Information
Specifications
-
Type: Digital Thermometer (Not Predictive)
-
Measure Range: Temperature: 41-104°F (5-40°C)
-
Accuracy: ±0.4°F (±0.2°C)
-
Operating mode: Three years
-
Display: LCD
-
Memory: Three years
-
Battery: Included
-
Battery life: Not specified
-
Dimension: 420.00 mm x 124.00 mm
-
Weight: Not specified
-
Expected service life: Not specified
-
Ambient operating range: Temperature: -4 to 131°F (-20 to
55°C), Relative humidity: 15%~95%RH, Atmospheric Pressure: 70kPa ~
106kPa -
Storage and transportation condition: Temperature: -4 to 131°F
(-20 to 55°C), Relative humidity: 15%~95%RH, Atmospheric Pressure:
70kPa ~ 106kPa -
Ingress Protection Rating: IP 27
-
Classification: Type BF
-
Contraindication: No contraindication
Product Usage Instructions
Set the Thermometer
To set the thermometer, ensure the alarm is on. Press the On/Off
Button to confirm the Alarm Clock On/Off status.
Recall Memory
- Turn off the thermometer.
- Press the UP or Down Button to enter memory mode.
- Press the UP or Down Button to view the memory.
- Press the On/Off Button to power off.
Delete All Memory
-
In the memory mode, press and hold UP and Down Button until the
“Choose Whether to Delete Memory” screen is displayed. -
Press the UP/Down Button to select whether to delete all
memories. -
Press the On/Off Button to confirm whether to delete all
memories.
Delete One Memory
-
In the memory mode, press UP or Down Button to stop at the
memory you want to delete. -
Press and hold the On/Off Button until the “Choose Whether to
Delete Memory” screen is displayed. -
Press the UP/Down Button to select whether to delete the
memory. -
Press the On/Off Button to confirm whether to delete the
memory. -
Return to the Display memory value screen.
Frequently Asked Questions (FAQ)
Q: Can this thermometer be used for infants?
A: Yes, this thermometer can be used on people of all ages,
including children under 8 years old with adult supervision.
Q: What should I do if the device is exposed to mechanical
shock?
A: If the device is exposed to mechanical shock, its performance
may be degraded. Contact customer support for assistance.
“`
420.00 mm
124.00 mm
Digital Thermometer
OWNER’S MANUAL
Model:DMT-4770b
Warning :
Read instructions thoroughly before using digital thermometer. Choking Hazard:
Thermometer cap and battery may be fatal if swallowed. Do not allow children
to use this device without parental supervision. Do not use thermometer in
ear. Designed use is for oral, rectal, and armpit (axilla) readings only. Do
not place thermometer battery near extreme heat as it may explode. Remove
battery from the device when not in operation for a long time. The use of
temperature readings for self-diagnosis is dangerous. Consult your doctor for
the interpretation of results. Self-diagnosis may lead to the worsening of
existing disease conditions. Do not attempt measurements when the thermometer
is wet as inaccurate readings may result. Do not bite the thermometer. Doing
so may lead to breakage and/or injury. Do not attempt to disassemble or repair
the thermometer. Doing so may result in inaccurate readings. After each use,
disinfect the thermometer especially in case the device is used by more than
one person. Do not force the thermometer into the rectum. Stop insertion and
abort the measurement when pain is present. Failure to do so may lead to
injury. Do not use thermometer orally after being used rectally. For children
who are two years old or younger, please do not use the devices orally. If the
unit has been stored at temperatures over 41 104(5 40) , leave it in 41 104 (5
40) ambient temperature for about 15 minutes before using it. Use of this
equipment adjacent to or stacked with other equipment should be avoided
because it could result in improper operation. If such use is necessary, this
equipment and the other equipment should be observed to verify that they are
operating normally. PORTABLE RF communications equipment (including
peripherals such as antenna cables and external antennas)should be used no
closer than 30 cm (12 inches) to any part of the [ME EQUIPMENT or ME
SYSTEM],including cables specified by the MANUFACTURER. Otherwise, degradation
of the performance of this equipment could result. It is not intended for use
in the oxygen rich environment and presence of flammable anesthetic mixture
with air, oxygen or nitrous oxide. Do not put the thermometer in direct
sunlight or with cotton wool, otherwise the accuracy will be affected. ME
equipment should not be cleaned and disinfected while in use.
Indications For Use
The digital thermometers are intended to measure the human body temperature in
regular mode orally, rectally or under the arm. And the devices are reusable
for clinical or home use on people of all ages, including children under 8
years old with adult supervision.
Expected Operator
·The patient is an intended operator. The Applied part is the probe. ·All
functions the patient can safely use. ·The patient can replace the batteries.
PLEASE READ CAREFULLY BEFORE USING
This digital thermometer provides a quick and highly accurate reading of an
individual’s body temperature. To better understand its functions and to
provide years of dependable results, please read all instructions first. This
appliance conforms to the following standards: ASTM E1112 Standard
Specification for Electronic Thermometer for Intermittent Determination of
Patient Temperature, ISO 80601-2-56 Medical electrical equipment –Part
2-56:Particular requirements for basic safety and essential performance of
clinical thermometers for body temperature measurement, IEC 60601-1-11 Medical
electrical equipment –Part 1-11: General requirements for basic safety and
essential performance Collateral Standard: Requirements for medical
electrical equipment and medical electrical systems used in the home
healthcare environment and complies with the requirements of IEC
60601-1-2(EMC), AAMI/ANSI ES60601-1(Safety) standards. And the manufacturer is
ISO 13485 certified.
CONTENTS
1 Thermometer, 1 Owner’s Manual, 1 Storage Case
PRODUCT ILLUSTRATION Figure 1
LCD Up/Down Button
Probe
On/Off Button
PRECAUTION
The performance of the device may be degraded should one or more of the following occur: – Operation outside the manufacturer’s s tated te mperature and humidity range. – Storage outside the manufacturer’s s tated te mperature and humidity range. – Mechanical shock (for example, drop test) or degraded sensor. – Patient temperature is below ambient temperature. Portable and mobile RF communications can affect the device. The device needs special pre-cautions
regarding EMC according to the EMC information provided in the accompany
documents. *Do not use the devices in the MR environment.
SYMBOL EXPLANATION
Caution
Direct Current
TYPE BF APPLIED PART
Date of manufacture
Batch Code
Refer to instruction manual/booklet
95%
106kPa
15%
Storage and Transportation Humidity limitation: 15%~95%RH 70kPa
Atmospheric pressure limitation
Manufacturer rGeecnoevrearly/syremcbyocllafbolre
Disposal of this product and used batteries should be
131 oF Storage and Transportation Temperature Limit: -4 131
carried out in accordance with the national regulations for -4oF the disposal of electronic products.
(-20~55)
IP27 The first num.2:Protected against solid foreign objects of 12,5 mm and greater. The second num.7:Protected against the effects of temporary immersion in water.
SPECIFICATIONS
Type: Measure Range:
Accuracy:
Operating mode: Display: Memory: Battery: Battery life: Dimension: Weight:
Expected service life:
Ambient operating range:
Storage and transportation condition:
Ingress Protection Rating: Classification: Contraindication:
Digital Thermometer (Not Predictive)
89.60-109.38( 32.0042.99)( / chosen by manufacturer) ±0.1(±0.05) during
95.00~100.40(35.00~38.00) at 64.4~82.4 (18~28 ) ambient operating range
±0.2(±0.1) for other measuring and ambient operating range Direct Mode Liquid
crystal display, 4 ½ digits The last thirty memories One 3.0V DC button
battery type CR2032 Approx. 60hours of continuous operation or 6 months with 3
measurements per day 13.3cm×3.4cm×1.6cm(L x W x H) Approx. 23 grams including
battery
Three years
Temperature: 41104(540) Relative humidity: 15%~95%RH Atmospheric Pressure :
70kPa ~ 106kPa
Temperature: -4131(-20~55) Relative humidity: 15%~95%RH Atmospheric Pressure :
70kPa ~ 106kPa
IP 27
Type BF
No contraindication
Set the thermometer
1.Set / temperature unit Turn off the thermometer. Press and hold the On/Off
Button for approximately 2 seconds, until the / is flashing. Press the UP/Down
Button to choose /. Press On/Off Button to confirm the / unit. 2.Set Alarm
Clock Time Turn off the thermometer. Press the UP and Down Button, to enter
Clock Setting. Press UP/Down Button to choose time, press On/Off Button to
confirm . 3.Turn ON/OFF the Alarm Clock After confirmed the Alarm Clock will
enter setting the alarm to turn on or off Press the UP and Down Button, to
enter Clock Setting. Press the up or down button to turn the alarm on or off.
The alarm symbol is displayed when
the alarm is on, but not when the alarm is off . Press On/Off Button to
confirm the Alarm Clock On/Off.
Recall memory
Turn off the thermometer. Press the UP or Down Button to enter memory mode.
Press the UP or Down Button to view the memory. Press On/Off Button to power
off.
Delete all memory
In the memory mode, press and hold UP and Down Button until the Choose Whether
to Delete Memory screen is displayed .
Press the UP/Down Button to select whether to delete all memories. Press
On/Off Button to confirm whether to delete all memories.
Delete one memory
In the memory mode, press UP or Down Button to stop the interface at the
memory you want to delete. Press and hold the On/Off Button until the Choose
Whether to Delete Memory screen is displayed. Press the UP/Down Button to
select whether to delete the memory. Press On/Off Button to confirm whether to
delete the memory. Return to the Display memory value screen.
Bluetooth requirements
1. The thermometer requires a bluetooth device with: Bluetooth 4.0 or later
Android 6.0 or later *IOS 10.0 or later.
2. And works with: . iphone , iPod, iPad . Android Phones and Tablets.
DIRECTIONS
1. Press the On/Off Button next to LCD display. A tone will sound as the screen shows
,
the thermometer then goes into the testing mode.
2. Position thermometer in desired location (mouth, rectum, or armpit.) a) Oral Use: Place thermometer under tongue as indicated by” ”
position shown in Figure 1. Close your mouth and breathe evenly
through the nose to prevent the measurement from being influenced
by inhaled/exhaled air.
Figure 1
b) Rectal Use: Lubricate silver probe tip with petroleum jelly for easy insertion. Gently insert
sensor approximately 1cm (less than 1/2 “) into rectum.
c) Armpit Use: Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.
From a medical viewpoint, this method will always provide inaccurate readings, and should not
be used if precise measurements are required.
3. The degree sign flashes throughout the testing process. When flashing stops an alarm will beep.
The measured reading will appear on the LCD simultaneously. The measurement time until the signaling
tone (beep) must be maintained without exception.
4. To prolong battery life, press the On/Off Button to turn unit off after testing is complete. If no action
is taken, the unit will automatically shut off after around 5 minutes
*Note: Normally the buzzes are” Bi-Bi-“; Alarm beeps more rapidly when temperature reaches 37.8 (100) or higher ,and the buzzes are”Bi-Bi— Bi-Bi— Bi-Bi— Bi-Bi—Bi-Bi”
TROUBLESHOOTING
Error message
Problem
Solution
Temperature taken is lower Turn off, wait one minute and take a new temperature
than 89.60°F(32.00°C).
via close contact and sufficient rest.
Temperature taken is higher Turn off, wait one minute and take a new temperature
than 109.38°F(42.99°C).
via close contact and sufficient rest.
The system is not functioning properly.
The thermometer works properly.
Unload the battery, wait for 1 minute and repower it. If the message
reappears, contact the retailer for service.
Use the thermometer normally
When battery outline flashes, it indicates that the power is low, but you can
continue to measure.
The thermometer could not work due to low battery.
The thermometer will take a proper measurement but batteries must be replaced
soon.
Replace the battery.
BATTERY REPLACEMENT
1. Replace battery when ”
“o r”
” appears in the lower right corner of LCD display.
2. Put a thin board such as a coin on fillister of cover. Turn the battery anti-clockwise until the cover is off
(See Figure 2).
3. Use a non-meteal instrument such as a pen to remove old battery from the battery holder (See Figure 3). Discard battery according to local law.
4. Place a new 3.0V DC CR2032 into the chamber with positive side facing
up(See Figure4). 5. With a thin pin to turn the cover clockwise until the ” ”
facing towards ” “(See Figure 5)
Note: The following schematic diagram of battery replacement is from the back
of the thermometer.
After each battery replacement, the system enters the setting mode to set the unit and time.
Figure 2
Figure 3
Figure 4
Figure 5
CALIBRATION
The thermometer is initially calibrated at the time of manufacture. If the
thermometer is used according to the use instruction, periodic readjustment is
not required. However, we recommend checking calibration every two years or
whenever clinical accuracy of the thermometer is in question. Turn on the
thermometer and insert into the water bath and then check the laboratory
accuracy of thermometer. Please send the complete device to the dealers or
manufacturer. ASTM laboratory accuracy requirements in the display range of
98.6 to 102.2 °F(37.0 to 39.0 °C) for electronic thermometers is
±0.2°F(±0.1°C). The above recommendations do not supersede the legal
requirements. The user must always comply with legal requirements for the
control of the measurement, functionality, and accuracy of the device which
are required by the scope of relevant laws, directives or ordinances where the
device is used.
CLEANING AND DISINFECTION
1)Immerse the thermometer probe in distilled water for at least 1 minute;
2)Using a clean, soft cloth to wipe the thermometer down to remove any
residue; 3)Repeat step 1 and 2 for three times until no soil is seen with
visual inspection after cleaning; 4)For thoroughly clean and disinfection,
please use method A or B
Method A(High level disinfection): immerse the thermometer probe in 0.55%
OPA(O-Phthaldehyde), such as CIDEX OPA, for at least 12 minutes under
temperature at 68(20); Method B(Low level disinfection): Using a clean soft
cloth dipped in 70% medical alcohol,wipe the probe 3 times,at least one minute
for each time. 5)Repeat step 1 to 3 to remove OPA residuals; Note1: Rectal use
is not recommended for home use as OPA will not be readily available outside
of a hospital. If rectal measurement is necessary, we strongly recommend high
level disinfection. Note2: Please operate according to the manual of OPA for
reference. To prevent damage to the thermometer please note and observe the
following: -Do not use benzene, paint thinner, gasoline or other strong
solvents to clean the thermometer. -Do not attempt to disinfect the sensing
probe (tip) of the thermometer by immersing in alcohol, OPA or in hot water
(water over 122(50) for long time. -Do not use ultrasonic washing to clean the
thermometer.
FCC INFORMATION
FCC Warning: Any Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment. This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Note: This
equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: -Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver. -Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. -Consult the dealer or an experienced radio/TV
technician for help. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter. The device has been
evaluated to meet general RF exposure requirement. The device can be used in
portable exposure condition without restriction.
124mm
LIMITED WARRANTY
The thermometer is guaranteed for one year from the date of purchase. If the
thermometer does not function properly due to defective components or poor
workmanship, we will repair or replace it free of charge. All components are
covered by this warranty excluding the battery. The warranty does not cover
damages to your thermometer due to improper handling. To obtain warranty
service, an original or copy of the sales receipt from the original retailer
is required. The software identifier refers to the Software validation Report
document, and the file code is JYRJ201203004 the file version is A0.
Disposal of this product and used batteries should be carried out in
accordance with the national regulations forthe disposal of electronic
products.
JOYTECH Healthcare Co., Ltd. NO.502, Shunda Road, 311100 Hangzhou, Zhejiang
Province, PEOPLE’s REPUBLIC OF CHINA
Made in China
Document No.: JDMT-9204-011 Article No.: 001 Version: Z
Date of Issue: 2023.07
320mm
124mm
320mm
Read User Manual Online (PDF format)