metabo FMS 200 200W Palm Tri Sander Instruction Manual

May 15, 2024
metabo

FMS 200 Intec Original instructions

FMS 200 200W Palm Tri Sander

| FMS 200 Intec
*1) Serial Number: 00065..
---|---
A| mm (in)| 100 x 147 (3 15/16 x 5 3/4)
P 1| W| 200
P 2| W| 80
s 0| min-¹ (opm)| 26.000
s 1| min-¹ (opm)| 22.000
S| mm (in)| 1,4 (1/16)
Intec| –| P
m| kg (lbs)| 1,25 (2.76)
a h,Kh| m/s²| 5,5 / 1,5
L pA ,K pA| dB(A)| 78 / 3
L WA ,K WA| dB(A)| 89 / 3

*** 2) 2011/65/EU, 2006/42/EC, 2004/108/EC (->19.04.2016), 2014/30/EU (20.04.2016->)
3) EN 60745-1, EN 60745-2-4 -1:2009 + A11:2010; -2-4:2009+A11:2011
2015-07-22, Volker Siegle
Direktor Produktentstehung & Qualität (Vice President Product Engineering & Quality)
4) Metabowerke GmbH – Metabo-Allee 1 – 72622 Nuertingen, Germany

| 6.25600
---|---
| 6.25600
| 6.25602
| 10 x P 40 . . . . 6.25603
10 x P 60 . . . . 6.25604
10 x P 80 . . . . 6.25605
10 x P 100 . . . . 6.25606
10 x P 120 . . . . 6.25607
10 x P 180 . . . . 6.25608
10 x P 240 . . . . 6.25609
2 x P 40 +
2 x P 80 +
2 x P 120 +
2 x P 180 +
2 x P 240 . . . . 6.25610
| 10 x P 40 . . . . 6.25611
10 x P 60 . . . . 6.25612
10 x P 80 . . . . 6.25613
10 x P 100 . . . . 6.25614
10 x P 120 . . . . 6.25615
10 x P 180 . . . . 6.25616
10 x P 240 . . . . 6.25617
2 x P 40 +
2 x P 80 +
2 x P 120 +
2 x P 180 +
2 x P 240 . . . . 6.25618

Declaration of Conformity

We declare under our sole responsibility: These multisanders, identified by type and serial number 1), comply with all relevant requirements of the directives 2) and standards 3). Technical file at 4) – see page 3.

Specified Use

The machine is suitable for dry sanding of flat and elliptical surfaces, wood, plastics, non-ferrous metals, sheet metal and similar filled and painted surfaces.
The user bears sole responsibility for damage caused by improper use.
Generally accepted accident prevention regulations and the enclosed safety information must be observed.

General Safety Instructions

For your own protection and for the protection of your electrical tool, pay attention to all parts of the text that are marked with this symbol!
WARNING – Reading the operating instructions will reduce the risk of injury.
WARNING Read all safety warnings and instructions. Failure to follow all safety warnings and instructions may result in electric shock, fire and/or serious injury.
Keep all safety instructions and information for future reference.
Pass on your electrical tool only together with these documents.

Special Safety Instructions

Pull the plug out of the socket before making any adjustments, changing tools, carrying out maintenance or cleaning.
Secure the workpiece against slipping, e.g. with the help of clamping devices.
Wear ear protectors when working for long periods of time. High noise levels over a prolonged period of time may affect your hearing.
Reducing dust exposure:
**** Some of the dust created using this power tool may contain substances known to cause cancer, allergic reaction, respiratory disease, birth defects or other reproductive harm. Some examples of these substances are: lead (from lead-based paints), crystalline silica (from bricks cement, etc.), additives for wood treatment (chromate, wood preservative), some types of wood (like oak and beech dust), metals, asbestos.
The risk from exposure to such substances will depend on how long the user or nearby persons are being exposed.
Do not let particles enter the body.
To reduce exposure to these substances: work in a well ventilated area and wear protective equipment, such as dust masks that are specially designed to filter out microscopic particles.
Observe the relevant guidelines for your material, staff, application and place of application (e.g. occupational health and safety regulations, disposal).
Collect the generated particles at the source, avoid deposits in the surrounding area.
Use only suitable accessories. In this way, fewer particles enter the environment in an uncontrolled manner.
Use a suitable extraction unit.
Reduce dust exposure with the following measures:

  • Do not direct the escaping particles and the exhaust air stream at yourself or nearby persons or on dust deposits.
  • Use an extraction unit and/or air purifiers.
  • Ensure good ventilation of the workplace and keep it clean using a vacuum cleaner. Sweeping or blowing stirs up dust.

Vacuum or wash protective clothing. Do not blow, beat or brush.

Overview

See page 2.

1 Sanding disc
2 Sanding plate
3 On/off switch| 4 Dust collection box
5 Cleaning flap
6 Fluted filter
---|---

Commissioning

Before plugging in, check to see that the rated mains voltage and mains frequency, as stated on the rating label, match your power supply.
Always install an RCD with a maximum trip current of 30 mA upstream.

6.1 Installation of sanding disc
Simple attachment and removal thanks to the velcro-type fastening.
Simply press on the sanding disc such that the holes in the sanding disc (1) and sanding plate (2) are aligned.

Use

7.1 Switching On and Off
Switching on: Move switch (3) to “I” position.
Switching off: Move switch (3) to “O” position.

7.2 Dust Extraction
To optimise the dust extraction performance, fit the sanding disc such that the holes on the sanding disc (1) and sanding plate (2) are aligned.
Integrated extraction system:
Install the dust collection box (4) (see illustration, page 3). To optimise the extraction performance, empty the dust collection box (4) in good time and clean the filter (6).
External extraction system:
Fit dust extraction nozzle (see chapter on Accessories). Connect a suitable extraction device.
Use a suction hose with a 35 mm connector diameter. See Accessories section.
Note: When sanding abrasive material (e.g. plaster, etc.) we recommend connecting a suitable dust extractor.

Cleaning, Maintenance

Empty dust collection box (4).

  • Open cleaning flap (5).
  • Empty dust collection box (4).
  • Remove fluted filter (6) and knock off dust stuck to filter or remove with brush.
  • When inserting, ensure that the fluted filter (6) is inserted in the lateral guides.

Clean the machine regularly.
This includes vacuum cleaning the ventilation louvres on the motor.
Replacing worn sanding plate (2)

  • Remove fixing screws (on lower side of sanding plate).
  • Take off sanding plate.
  • For sanding plate (as replacement), refer to the Accessories chapter.
  • Mount sanding plate.
  • Refit fixing screws (on lower side of sanding plate) and tighten.

Accessories

Use only genuine Metabo accessories.
See page 4.
Use only accessories which fulfil the requirements and specifications listed in these operating instructions.
A Sanding plate (as replacement)
B Dust collection box with fluted filter for multiple cleaning (as replacement)
C Fluted filter (as replacement)
D Perforated adhesive sanding discs for all types of wood, 2-piece, 100 x 150 mm
E Perforated adhesive sanding discs for paint, lacquer, spattle, 2-piece, 100 x 150 mm
F Dust extraction connection
G Metabo universal vacuum cleaner
For complete range of accessories, see www.metabo.com or the main catalogue.

Repairs

Repairs to electrical tools must be carried out by qualified electricians ONLY!
The connection cable must only be replaced by Metabo or an authorised customer service workshop.
If you have Metabo electrical tools that require repairs, please contact your Metabo service centre.
For addresses see www.metabo.com.
You can download spare parts lists from www.metabo.com.

Environmental Protection

Observe national regulations on environmentally compatible disposal and on the recycling of disused machines, packaging and accessories.
**** Only for EU countries: Never dispose of power tools in your household waste! In accordance with European Guideline 2002/ 96/EC on used electronic and electric equipment and its implementation in national legal systems, used power tools must be collected separately and handed in for environmentally compatible recycling.

Technical Specifications

Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
D = Dimensions of sanding plate
P1 = Nominal power input
P2 = Power output
s0 = orbital frequency at no load
s1 = orbital frequency at nominal load
S = Oscillating circuit diameter
Intec = Dust collection box
m = Weight without mains cable
Measured values determined in conformity with EN 60745.
Machine in protection class II
~ Alternating current
The technical specifications quoted are subject to tolerances (in compliance with the relevant valid standards).
Emission values
These values make it possible to assess the emissions from the power tool and to compare different power tools. Depending on the operating conditions, the condition of the power tool or the accessories, the actual load may be higher or lower.
For assessment purposes, please allow for breaks and periods when the load is lower. Based on the adjusted estimates, arrange protective measures for the user e.g. organisational measures.
Vibration total value (vector sum of three directions) determined in accordance with EN 60745:
ah = Vibration emission value (Surface sanding)
Kh =Unsafe (vibration)
Typical A-effective perceived sound levels:
LpA =Sound pressure level
LWA =Acoustic power level
KpA, KWA = Uncertainty
During operation the noise level can exceed 80 dB(A).
Wear ear protectors!

Metabowerke GmbH Metabo-Allee 1
72622 Nuertingen Germany
www.metabo.com

Documents / Resources

| metabo FMS 200 200W Palm Tri Sander [pdf] Instruction Manual
FMS 200 200W Palm Tri Sander, FMS 200, 200W Palm Tri Sander, Palm Tri Sander
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals