RECTORSEAL AG-1100 Magnetic Float Switch Instruction Manual

May 15, 2024
Rectorseal

RECTORSEAL logo

Installation Instructions
AG-1100+
Wiring the AquaGuard® AG-1100+ – Magnetic Float Switch

WORK SAFE, READ THIS!

ATTENTION: FAILURE TO READ AND COMPLY WITH ALL WARNINGS, CAUTIONS AND INSTRUCTIONS PRIOR TO STARTING INSTALLATION MAY CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE AND VOID WARRANTY.
ATTENTION: Clean surface with alcohol pad before mounting with adhesive tape.

Work Safe, READ THIS!
ATTENTION: FAILURE TO READ AND COMPLY WITH ALL WARNINGS, CAUTIONS AND INSTRUCTIONS PRIOR TO STARTING INSTALLATION MAY CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE AND VOID WARRANTY.
STOP/READ: This device must be installed in accordance with manufacturer’s instructions. This unit must be in accordance with all applicable local plumbing, drainage and electrical codes.
WARNING: Remove electrical shock hazard – DISCONNECT THE POWER BEFORE INSTALLING AQUAGUARD to avoid electrical shock and/or equipment damage.
Do not use on circuits exceeding 24 volts to avoid damage to switch, shock or fire hazard.
CAUTION: In some situations the switch may cause the unit to rapidly cycle on and off as water level rises slowly in pan. After a brief period the unit will turn off completely. Condensation drain must be serviced if this occurs.
CAUTION: In any installation where property damage and/or personal injury might result from an inoperative switch due to power outages, a back-up system(s) and or alarm should be installed.
NOTICE: The AquaGuard AG-1100+ must only be installed by a licensed contractor or under the direct supervision of same. Condensation pan must be properly maintained after installation and be kept free from foreign objects, rust or other obstructions that might interfere with the proper operation of the AquaGuard float switch.

INSTALLATION OF FLOAT SWITCH ON DRAIN PAN:

(To ensure proper performance of product, instructions must be followed.)

  1. Disconnect power to unit at main panel. Disconnect power to the low voltage thermostat circuit.
  2. Slide the float switch onto the side of the pan.
  3. Secure switch wires so they will not affect the operation of the float.
  4. Secure the float switch by tightening thumb screws. (fig.1) Do not over tighten.

WIRING THE AG-1100+ in a Conventional HVAC System:

  1. Ensure the power is disconnected to the unit at the main panel prior to moving to step 2.
    Refer to the appliance manufacturer’s installation and operating instructions and also review wire layout in their instructions.

  2. Locate the red wire coming from the 24 volt thermostat “R” terminal.

  3. Disconnect or cut red wire. Connect the non-ribbed wire of the switch, using a wire nut, to the thermostat side of the circuit. Connect the ribbed wire of the switch, using a wire nut, to the air handler side of the circuit or to terminal in unit. Incorporating  both switch wires in the red circuit will shut the unit completely off.

  4. Test the switch. (At start-up check initial amperage load.)
    A. With unit on, test switch by pulling the float pin up. (fig. 2) Unit should stop running if switch is correctly wired.
    B. To test switch responsiveness fill pan with water to ensure that the switch stops the unit before the pan overflows. Remove water.

  5. Place the ATTENTION sticker on unit in a clearly visible location. (fig. 3)RECTORSEAL AG-1100 Magnetic Float Switch - Fig 2

  6. For wiring the normally open third wire (short wire) refer to the following diagrams:

RECTORSEAL AG-1100 Magnetic Float Switch - Fig 3

WIRING the AG1100+ in a Communicating HVAC System:

  1. See equipment manufacturers recommendations for specific wiring instructions.

LIMITED WARRANTIES AND LIMITATION OF LIABILITY

REGISTER YOUR PRODUCT ONLINE: www.rectorseal.com
1 YEAR SWITCH AND SENSOR LIMITED WARRANTY AND LIMITATION OF LIABILITY
The limitations of liability set forth below include body and all component parts as well as the product itself as a whole.
RectorSeal warrants to the original consumer purchaser (“Purchaser) of its AquaGuard switch and sensor products, that they are free from defects in material or workmanship for a period of one (1) year from the date of purchase. If this product shall prove to be defective within the one (1) year period from the date of purchase, it shall be repaired or replaced, at RectorSeal ‘s option, subject to the GENERAL TERMS and CONDITIONS set forth below. EXCLUSIONS
This warranty does not cover damages resulting from use of components or accessories not approved by RectorSeal. 3, and 10 YEAR SECONDARY DRAIN PAN LIMITED WARRANTY AND LIMITATION OF LIABILITY This warranty applies only to secondary drain pans installed in the United States and Canada.
RectorSeal warrants to the original consumer purchaser (“Purchaser”) of its AquaGuard secondary drain pan products, that they are free from defects in material or workmanship for a period of three (3) years for Titan pan models, ten (10) years for Goliath and Goliath Furnace models, from the date of purchase. If this product shall prove to be defective within the three, five or ten (3, or 10) year period from the date of purchase, it shall be repaired or replaced, at Rectorseal’s option, subject to the GENERAL TERMS
and CONDITIONS set forth below.
This warranty extends only to the original consumer purchaser and is nontransferable.
EXCLUSIONS
This warranty does not cover damages resulting from the use of corrosive material (including, but not limited to: Acetone, MEK and petroleum-based products); nor damages resulting from use of components or accessories not approved by RectorSeal.

GENERAL TERMS AND CONDITIONS
To be eligible for the warranty the purchaser must provide RectorSeal with the following:

  1. Proof of Purchase (Original Receipt)
  2. Installer’s Testimony
  3. Original Product
  4. Original Work Order
  5. Photos of Installation

PURCHASER MUST PAY ALL LABOR AND SHIPPING CHARGES NECESSARY TO REPLACE PRODUCT COVERED BY THIS WARRANTY. This warranty shall not apply to acts of God, nor shall it apply to products which, in the sole judgment of RectorSeal have been subject to negligence, abuse, accident, tampering, misapplication, alteration; nor due to improper installation, operation or maintenance or storage; nor moved from its original place of installation; nor to other than normal application, use or service, including but not limited to, operational failures caused by corrosion, rust or other foreign materials in the system. Requests for service under this warranty shall be made by returning the defective product to the Retail outlet or to RectorSeal as soon as possible after the discovery of any alleged defect. RectorSeal will subsequently take corrective action as promptly as reasonably possible. No requests for service under this warranty will be accepted if received more than thirty-one (31) days after the term of the warranty.1hiswarranty sets forth Rectorseal’s sole obligation and purchaser’s exclusive remedy for defective products. For your benefit and protection register your product online at www.rectorSeal.com within thirty (30) days of installation. This will initiate the Warranty period and will allow us to contact you, should it become necessary. In the absence of a recorded product registration, the Warranty period will begin upon product shipment from RectorSeal. In the event that RectorSeal attempts to contact consumers regarding a recall or other matter, and any damages occur, which could have been avoided by registration by the consumer, RectorSeal shall have no liability. IN ALL CIRCUMSTANCES, RECTORSEAL’S MAXIMUM LIABILITY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT ALONE. Warranty claims must be registered with RectorSeal within thirty (30) days of damage or malfunction. RectorSeal reserves the right to visit the site of the installation or to require documentation of the claim before assuming any responsibility under the provisions of this Warranty. Consumer agrees to inspect the product at the time of installation for any reasonable discernible defects and, further, agrees to inspect the product annually. Any damages occurring, which could have been avoided by proper inspection will not be the responsibility of RectorSeal. RECTORSEAL SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER TO THE PURCHASER OR ANY THIRD PARTY. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL EXPRESSED WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESSED WARRANTIES PROVIDED HEREIN. Some states do not allow the exclusion of limitation of incidental and consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.

VENUE: Any purchaser or third party actions brought for any reason hereunder shall be commenced in Houston, TX and no other jurisdiction, and such action shall be governed by and construed in accordance with the laws of the State of Texas. Any notice herein shall be sent by certified or registered mail to 2601 Spenwick Drive, Houston, TX USA

24 VAC, 5 amps
RectorSeal® Houston, TX USA www.rectorseal.com US Patent 7,710,283
R50118 0119